12.07.2015 Views

NIBE F1330 - Klimats24.lv

NIBE F1330 - Klimats24.lv

NIBE F1330 - Klimats24.lv

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installation / AdjustmentDescription of functions - Basic functionsHeating medium pumps (VBP-A/VBP-B and VBP3)The operating mode for the heating medium pump forcompressor A/B (VBP-A/VBP-B) can be set separately foreach heat pump in menu 5.4.7/5.4.8.The external heating medium pump’s (VBP3) operatingmode is set in menu 6.1.1.The settings for the economy operating mode are the samefor both pumps and are set in menus 6.1.2 and 6.1.3.Connection of heating medium pump VBP3The external heating medium pump’s (VBP3) control signalis connected to the terminal block X6:1 (230 V), X6:2 (N)(max 0.2 A).Quick guide - menu settingsHeating medium pumps (VBP-A/VBP-B, VBP3)Menu 5.4.7 / 5.4.8 Oper.mode heat pump A / B [U]The operating mode for the heating medium pump A/B(VBP-A/VBP-B) is set here. Selectable options are:Intermittent: The heating medium pump starts 20 secondsbefore and stops 20 seconds after the compressor.Continuous: Continuous operation.Economy: The pump is operational a specific time perperiod (see menu 6.1.2 and 6.1.3), and together withthe compressor.The factory setting is Intermittent.Economy and Continuous operation are only recommendedwhen there is no external circulation pump.Menu 6.1.1 Op-mode external cp[U]The operating mode for an external heating mediumpump (VBP3) is set here. Selectable options are:Continuous: Continuous operation.Economy: The pump is operational a specific time perperiod (see menu 6.1.2 and 6.1.3), and together withthe compressor.The factory setting is Continuous.When economy mode is set in menu 5.4.7 the setting inthis menu must also be set to economy.Menu 6.1.2 Periodtime economy[U]The period time for economy mode is set here. This appliesto heating medium pump A/B (VBP-A/VBP-B) whenEconomy is selected in menu 5.4.7/5.4.8, and/or the externalheating medium pump (VBP3) when Economy isselected in menu 6.1.1. Adjustable between 5 and 120minutes. The factory setting is 20 minutes.HeatingThe outdoor temperature (UG) and set value for heat curvegive a theoretical set point value, which the building’sheating system needs in order to heat the house. The setpoint value as a function of the true flow temperature (FG)gives a value in degree-minutes as a basis for operation inheating mode.The desired operating mode with regard to permitting/blockingof the circulation pump and additionalheating is set using the Operating modebutton. The selection does not need to be confirmedwith the enter button.The current operating mode is shown on the display whenthe button is pressed and the mode changes when youcontinue to press the button. The display returns to thenormal display mode once the enter button is pressed.The different operating modes are:Auto mode:<strong>F1330</strong> automatically selects the operating mode by takingthe outdoor temperature into account. The circulationpumps and additional heating are permitted to be operationalwhen the need arises.Summer mode:Only hot water production using <strong>F1330</strong>. The circulationpumps and additional heating are blocked. However, whenExtra hot water is activated the additional heat (XVV) canbe connected.Spring/Autumn mode:Only production of heating and hot water using <strong>F1330</strong>.The circulation pumps are operational. Additional heatblocked. However, when Extra hot water is activated theadditional heat (XVV) can be connected.Only additional heat:Compressors blocked. The function can also be activated/deactivated by pressing the “operating mode button” for7 seconds.X1X6Menu 6.1.3 Operating-time economy [U]The operating time per period for the economy modeis selected here. This applies to heating medium pumpA/B (VBP-A/VBP-B) when Economy is selected in menu5.4.7/5.4.8, and/or the external heating medium pump(VBP3) when Economy is selected in menu 6.1.1.Adjustable between 1 and 120 minutes.The factory setting is 5 minutes.X4LEK22 <strong>NIBE</strong> <strong>F1330</strong>The heat pump in the picture is fitted with accessories.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!