12.07.2015 Views

NIBE F1330 - Klimats24.lv

NIBE F1330 - Klimats24.lv

NIBE F1330 - Klimats24.lv

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installation / AdjustmentDescription of functions - Basic functionsFixed condensingWith fixed condensing the compressor start for heatcharging is regulated using the flow line sensor (FG). Thestart and stop temperatures can be set in the sub-menusto 2.7.0. The compressors and additional heating steps arestarted and stopped with a 0.5 degree minus difference.That is to say, if compressor 1 starts at 50 °C and stops at55 °C, compressor 2 starts at 49.5 °C and stops at 54.5 °Cetc.When the sub shunt (SV-V2) is required this can beconnected to the Expansion card 11, see the sectionDescription of functions - Expansion card 11 > Sub shunt.Connection of fixed condensingThe flow line sensor (FG) is ideally placed in a submergedtube in the working tank, boiler or the like.To connect the sub shunt (SV-V2) see the sectionDescription of functions - Expansion card 11 > Sub shunt.Quick guide - menu settingsfixed condensingMenu 9.1.7 Fixed condensingHere fixed condensing is set either On or Off.The factory setting is Off.Menu 2.7.1 Starttemp.compressor[S]Temperature on the flow line sensor (FG) when the firstcompressor starts. The value is adjustable between 5and 60 °C. The factory setting is 47 °C.Menu 2.7.2 Stoptemp. compressorTemperature on the flow line sensor (FG) when the lastcompressor stops. The value is adjustable between 5and 60 °C. The factory setting is 50 °C.Menu 2.7.3 Starttemp. additive[U][U][U]Temperature on the flow line sensor (FG) when additionalheating engages. The value is adjustable between5 and 60 °C. The factory setting is 45°C.Menu 2.7.4 Stoptemp. additiveTemperature on the flow line sensor (FG) when additionalheating disengages. The value is adjustable between5 and 60 °C. The factory setting is 49 °C.[U]Floor drying functionIn order to obtain the correct drying of new concretefloors, the integrated floor drying function can be used.The function forces the temperature on the flow line sensor(FG) to fixed temperatures irrespective of the outdoortemperature and curve settings.The settings for the function can be found in the submenusto 9.2.0.Once the selected program is complete, control of the flowtemperature automatically returns to normal operation.Quick guide - menu settingsfloor drying functionMenu 9.2.1 Op-mode floor dryingThe operating mode for the floor drying function is sethere. Selectable modes are:Off: Normal operation, i.e. the floor drying function isswitched off.[S]Own program: Two fixed temperatures in two periodsare adjustable in menu 9.2.3 to 9.2.6.Fixed program: The flow temperature starts day 0 at20 degrees and increases each day by 5 degrees. Thetemperature has reached 45 degrees on day 5, this ismaintained on days 6 and 7. The program is terminatedby lowering the temperature on days 8 to 12 by 5 degreeson each day.The factory setting is Off.Menu 9.2.2 Floor drying day[U]Here you can see which day the floor drying functionis on. It is also possible here to enter the floor dryingprogram by changing this value. The value is adjustablefrom 0 to 20 days. The factory setting is 0.Menu 9.2.3 Nos. of days per. 1[U]Here you set the number of days that the flow temperatureshall maintain the temperature in menu 9.2.4 whenOwn program in menu 9.2.1 is selected. The value isadjustable between 1 and 10 days. The factory settingis 5 days.Menu 9.2.4 Temperature per. 1[U]Here you set the temperature to be maintained on theflow line sensor (FG) during period 1 when Own programis selected in menu 9.2.1. The value is adjustablebetween 15 and 50 °C. The factory setting is 25 °C.Menu 9.2.5 Nos. of days per. 2[U]Here you set the number of days that the flow temperatureshall maintain the temperature in menu 9.2.6 whenOwn program in menu 9.2.1 is selected. The value isadjustable between 1 and 10 days. The factory settingis 5 days.The outline diagram with docking instructions isavailable at www.nibe.comMenu 9.2.6 Temperature per. 2[U]Here you set the temperature to be maintained on theflow line sensor (FG) during period 2 when Own programis selected in menu 9.2.1. The value is adjustablebetween 15 and 50 °C. The factory setting is 35 °C.32 <strong>NIBE</strong> <strong>F1330</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!