Immediate Integrity Assessment<br />

• Assessment Pressure: MAOP 850 psi<br />

• The corrosion anomalies were assessed:<br />

– <strong>to</strong> Modified B31G in terms of their axial dimensions<br />

– <strong>An</strong>omalies that require repair within 5 years have also<br />

been assessed <strong>to</strong> Detailed RSTRENG<br />

– Kastner in terms of circumferential dimensions<br />

• The manufacturing <strong>and</strong> girth weld features were assessed <strong>to</strong><br />

Shannon <strong>and</strong> Kastner<br />

• <strong>An</strong>omalies require repair if:<br />

– Their reported dimensions exceed the size <strong>to</strong>lerable at the<br />

MAOP x safety fac<strong>to</strong>r (1.39); or<br />

– Their maximum reported depths exceed 80% wt.<br />

• The assessment has been conducted allowing for <strong>to</strong>ol depth<br />

sizing <strong>to</strong>lerances