Recommendations – Post Re-Inspection<br />
• <strong>An</strong> integrity assessment should be carried out <strong>to</strong>:<br />
– Determine the significance of the reported features<br />
– This should be based on actual depths at the time of<br />
new inspection rather than those predicted from this<br />
inspection<br />
– Provide confirmation that the mitigation measures put<br />
in place have controlled the threat of external<br />
corrosion <strong>to</strong> this pipeline<br />
– Identify areas of probable CP shielding, where<br />
adequate “off”-potentials have been recorded, but ILI<br />
data show continued growth<br />
• This should assist with ensuring the future integrity of the<br />
pipeline