Pipeline Summary<br />
• 12” x 30 mile refined product pipeline.<br />
• Constructed in 1975 from seamless pipe.<br />
• API 5L Grade X42.<br />
• The nominal wall thickness varies from 0.188” <strong>to</strong> 0.322”.<br />
• Reported Maximum Operating Pressure (MOP) is 850 psi.<br />
• Tar Tape Wrap Coating.<br />
• Impressed current CP system.<br />
• Inspected in 2009 by ROSEN (CDX) <strong>and</strong> in 2006 by ROSEN<br />
(CDP & EGP).