External <strong>Corrosion</strong><br />

• Location 1: 0-7 Miles<br />

– Depleted ground bed at the start of the line - CP underprotection<br />

– Ground bed <strong>to</strong> be re-instated<br />

• Location 2: 7.2-9.4 Miles<br />

– Coating disbondment<br />

– Rectifier no power (between 2004-2006)<br />

• Location 3: at ~28 Miles<br />

– Two foreign line crossings, potential stray current issue<br />

– Corrosive soil, resistivity of 1000 Ω-cm, poor coating condition<br />

– Rectifier <strong>to</strong> be installed <strong>to</strong> raise potentials, or re-coating of ~5<br />

miles<br />

• Large number of repairs completed including remedial work on<br />

CP system<br />

• A potential disbonded coating issue remains