11corresponding to T 1 . With radiation falling upon the bolometer, the temperature changesby AT to a new value T.Figure 2.2 A simple bolometer circuit.For the analysis, it is assumed that all the radiation incident upon the detector isabsorbed uniformly throughout the volume, the material is uniform throughout thevolume, and non-uniform Joulean heating is ignored. In absence <strong>of</strong> radiation with biasonrrent in the rirrnit the heat transfer Pnimtinn is oiven hvand the surrounding at T 0. The term on the right hand side <strong>of</strong> the equation is the Jouleanheating <strong>of</strong> the bolometer. With the presence <strong>of</strong> radiation P, the bolometer changes itstemperature by AT to T. The heat transfer equation becomes