12.07.2015 Views

Analysis of 320X240 uncooled microbolometer focal plane array ...

Analysis of 320X240 uncooled microbolometer focal plane array ...

Analysis of 320X240 uncooled microbolometer focal plane array ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

23provide protection against detector overheating in case <strong>of</strong> external clock failures and t<strong>of</strong>urnish the sensor with the UFPA status signals [10].The <strong>focal</strong> <strong>plane</strong> <strong>array</strong> consists <strong>of</strong> 320 x 240 <strong>microbolometer</strong> unit cells, which isformatted for 50% full TV resolution. A unit cell consists <strong>of</strong> a micro-bridge and readoutelectronics, which includes detector selection switch transistors, as shown in Figure 2.8.The microbridge structure is fabricated on top <strong>of</strong> the readout electronics. The firstgeneration <strong>of</strong> <strong>microbolometer</strong>s, made by Honeywell, used a bipolar transistor for detectorselection switch in the readout circuits. The second generation <strong>microbolometer</strong> readoutcircuit, the U3000' s made by Rockwell, uses MOSFET for their selection switch.