Effect of Automatic Sprinkler Protection on Smoke Control Systems

Effect of Automatic Sprinkler Protection on Smoke Control Systems

Effect of Automatic Sprinkler Protection on Smoke Control Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ti<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> 10,000 ppm were recorded, representing lifethreateninglevels <strong>on</strong> the fire floor. A rule <str<strong>on</strong>g>of</str<strong>on</strong>g> thumbsuggested by Kaplan and Hartzell (1984) indicates that at anexposure to 10,000 ppm <str<strong>on</strong>g>of</str<strong>on</strong>g> CO for more than 3.5 minutes,most people will be at least incapacitated. Peacock et al.(1989) indicated that a c<strong>on</strong>centrati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> 15,000 ppm COwould present a severe life-safety hazard to any<strong>on</strong>e trapped<strong>on</strong> the fire floor.Figures 12b and 13b show the c<strong>on</strong>centrati<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> C0 2and CO <strong>on</strong> the ninth floor <str<strong>on</strong>g>of</str<strong>on</strong>g> the Tower. In Figure 12b, noz<strong>on</strong>ed smoke c<strong>on</strong>trol was in effect, whereas in Figure 13b,the z<strong>on</strong>ed smoke c<strong>on</strong>trol system was set up for a t:J' design<str<strong>on</strong>g>of</str<strong>on</strong>g> 0.05 in. H 2 0 (12.5 Pa). In the former case, with noz<strong>on</strong>ed smoke c<strong>on</strong>trol in effect, for most <str<strong>on</strong>g>of</str<strong>on</strong>g> the fire durati<strong>on</strong>smoke was c<strong>on</strong>fmed to the fire floor. When the seventhfloordoor to the stairshaft was opened, however, smoke..,;c0::: 2.0• ~~03.05 10 15 20 25 30 35t.la:nill<strong>on</strong> Open 72.5c 9th Aoor: No Z<strong>on</strong>e <strong>Smoke</strong> C<strong>on</strong>trol• uFast Rcspcmsc <str<strong>on</strong>g>Sprinkler</str<strong>on</strong>g>s· Shielded F"trec0 • ea:ivatc94• a&rignitiOI'l(t.,• 16 min)u 1.50u.,•• 1.0N0u40 45 50 55 60 65 70 75 80Opea edt.Test 1150.5t.coo.o0 5 10 15 20 25 30. 35 40 45 50 55 60 65 70 75 80nme, minFigure 13a C0 2 and CO c<strong>on</strong>centrati<strong>on</strong>s <strong>on</strong> the ninth floor <str<strong>on</strong>g>of</str<strong>on</strong>g> the 10-story tower for a shielded fire with no z<strong>on</strong>ed smokec<strong>on</strong>trol in effect.0.22Test 120.20 co,0.1891hfloor. Z<strong>on</strong>e Smol:o Coaaol AP-O.ll5lo.1120..0.16 Slmdani Spriddcrs -Shlddod F ..,; • - 1221 aflerlgoilioa (It" 7 IIIia)c0::: 0.14!I•li 0.12u• 0u00.10u.,•o.oe•N 0.0680.040.02 it.£DlU<strong>on</strong>OpeaZSC DD 7'ftme. miDFigure 13b C0 2 and CO c<strong>on</strong>centrati<strong>on</strong>s <strong>on</strong> the ninth floor <str<strong>on</strong>g>of</str<strong>on</strong>g> the 10-story tower for a shielded fire with smoke c<strong>on</strong>trol ineffect.ASHRAE Transacti<strong>on</strong>s: Research507

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!