MAXIMUM FLOWRATE: 0000 gpmExample:Maximum Flow Rate of 0 gpmMASTER PROGRAMMING MODE FLOWRange: 20 - 2,000 gpm (U.S. Format)CHART continued20 - 200.0 L (Metric Format)NOTE: Only displayed if “Generic” is chosen for the flow meter.ADD 01 GALLONSEVERY 001 PULSESOptions: Gallons (U.S. Format)Liters (Metric Format)Range: 1 - 255Gallons (U.S. Format)0.1 - 09.9 L (Metric Format)Pulses: 1 - 255NOTE: Only displayed if “Generic” is chosen for the flow meter.PROGRAMMING UNITPLEASE WAIT...Example:Add 1 Gallon for Each Pulse in U.S. FormatExample:Master Programming Mode is ExitingUSER PROGRAMMING MODE FLOWCHARTEntering User Programming ModeHold the Set Up and Set Down buttons for 5 seconds.NOTE: User Mode is only displayed when a metered optionis chosen under System Type. Depending oncurrent option settings, some displays cannot beviewed or set.NOTE: User Mode cannot be entered on the Lag unit forSystem 6.DIAGNOSTIC PROGRAMMING MODEFLOW CHARTEntering Diagnostic Programming Mode1. Push and release the "D" button.2. Press the Extra Cycle button once per display until alldisplays are viewed and Normal Display is resumed.3. Push and release the"D" button at anytime duringdiagnostic mode and the timer will exit the mode.4. Depending on the current controller programming, certaindisplays may not be able to be viewed or set.Overview Diagnostic ModeThe current diagnostic will be displayed until Extra Cycle key ispressed. There is no time limit on each display. The timer willdisplay local information, not system information. In the eventof a regeneration occurring while displaying diagnostics, theregeneration step and time remaining will be displayed. Whenregeneration has been completed, the display will return to themain screen.CURRENT FLOWRATE:0 gpmPEAK FLOW RATE:0 gpmExample:Flow rate at this time.Example:Peak flow since last regeneration.TOTALIZER:130 gExample:Gallons at the outlet since installation.FEED WATERHARDNESS:gpgLAST TWO REGENS:0 HOURSExample:Hours between the last regeneration and theone before it.LAST REGEN0 HOURSExample:Hours since last regeneration.REGENERATION DAYOVERRIDE: OFFVOLUME REMAIN:1000 gExample:Volume remaining (can be adjusted).NOTE: If a System 6, Unit #1 of “Tank Remaining” will display “SystemRemaining”.REGENERATION DAYOVERRIDE:99 DAYSVALVE ADDRESS#2Example:Controller unit number.REGENERATIONTIME: 02:00AMVERSION:X.XXExample:Installed software level of the controller in use.10 • 3200 NXT FE12
NXT Multi LanguageProgramming Parameters and RangesSystem Type4TimeClockValve Address 1 2 3 4 1 2 3 4 1 2 1 2 3 4 1 2 3 4Select Language x x x x x x x x x x x x x x x x x x x x xSystem Size x x x x xRegen Type x x x x x x x x x x x x x x x x x x x x xValve Type x x x x x x x x x x x x x x x x x x x x xRegenerant Flow x x x x x x x x x x x x x x x x x x x x xRemote Signal Start x x x x x x x x x x x x xGallons LitersDisplay Format x x x x x x x x x x x x x x x x x x x x x US - Gallons EU - Metric-LitersUnit Capacity x x x x x x x x x x x x x x x x x 1 - 9900000 Grains 1 - 198000 gCaCO3Capacity Safety Factor x x x x x x x x x x x x x x x x x0- 50%Feed Water Hardness x x x x x x x x x x x x x x x x x 1 - 199 Grains/Gallons 1 - 1999 mgLTrip Point 1 x 0 - 997gpm 0 - 3997 LpmTrip Delay 1 x 30 - 99 Seconds 30 - 99 SecondsTrip Point 2 x Trip Point 1 + 1 - 998 gpm Trip Point 1 + 1 - 3998 LpmTrip Delay 2 x 30 - 99 Seconds 30 - 99 SecondsTrip Point 3 x Trip Point 2 + 1 - 999 gpm Trip Point 2 + 1 - 3999 LpmTrip Delay 3 x 30 - 99 Seconds 30 - 99 SecondsRegeneration Day Override x x x x x x x x x x x x x x x x xOff, 1 - 99Regeneration Time x o o o o o o o o o o o o o o o o o 12:00 a.m. - 11:59 p.m. 00:00 - 23:59 HourCycle 1 x x x x x x x x x x x x x x x x x x x x xCycle 2 x x x x x x x x x x x x x x x x x x x x xCycle 3 x x x x x x x x x x x x x x x x x x x x xCycle 4 x x x x x x x x x x x x x x x x x x x x xCycle 5 x x x x x x x x x x x x x x x x x x x x xAuxiliary Relay x x x x x x x u x x x u x x x x x x x x xAux Relay Output Start c c c c c c c c c c c c c c c c c c c c cAux Relay Output End c c c c c c c c c c c c c c c c c c c c cChemical Pump x x x x x x u u x x x x x x x xCPO Aux Relay Volume c c c c c c c c c c c c c c c c 1 - 999 gallons 0001 - 9999 LitersCPO Aux Relay Time c c c c c c c c c c c c c c c c 00:00:01 - 02:00:00 00:00:01 - 02:00:00Flow Meter x x x x x x x x x x x x x x x x 1" 1.5" Paddle or Turbine, 2" Paddle, 3" Paddle, GenericGeneric x x x x x x x x x x x x x x x xMaximum Flow Rate a a a a a a a a a a a a a a a a 20 - 2000 GPM 20 - 2000 LPMAdd _ _ _ Gallons or Liters a a a a a a a a a a a a a a a a 1 - 255 Gallons 001 - 255 LitersEvery _ _ _ Pulses a a a a a a a a a a a a a a a a 1 - 255 1 - 255Notes o -4MeteredImmediate4MeteredDelayed5Interlock6Series7AlternatingRegeneration Time will only be viewed if Regeneration Day Override is used.9Alternating14DemandRecallProgramming Parameter Ranges1 thru 4English, Espanol, Portugues, Deutsch, Francais1 thru 4Time Clock, Metered Delayed, Metered Immediate2750, 2850, 2900, 3150, 3900, StagerDownflow, Upflow, Upflow Fill FirstOff, 00:00:01 - 01:39:0000:00:00 - 04:00:00Off, 00:00:00 - 04:00:00Off, 00:00:00 - 04:00:00Off, 00:00:00 - 04:00:00Off, 00:00:00 - 04:00:00Enabled, Disabled00:00:01 to Total Regeneration Time - 1Start Time + 1 to Total Regeneration TimeEnabled, Disabledu -If Auxiliary Relay is Enabled then Chemical Pump Relay will not be viewed or if Chemical Pump Relay is Enabled then Auxiliary Relay will not be viewed.c -a -All Relay Output parameters programming will be viewed if Enabled.If Generic Flow Meter is chosen, then programming parameters will be viewed.3200 NXT FE12 • 11