<strong>SensoLyt</strong> ® <strong>700</strong> <strong>IQ</strong> (<strong>SW</strong>)Maintenance and changing the electrode5 Maintenance and changing the electrode5.1 General maintenance instructionsThe <strong>SensoLyt</strong> ® <strong>700</strong> <strong>IQ</strong> (<strong>SW</strong>) pH/ORP sensor operates maintenancefree.NotePlease read the maintenance of the combination electrode in therelevant operating manual of the electrode.WarningContact with the sample can lead to danger to the user!Depending on the type of sample, suitable protective measuresmust be taken (protective clothing, protective goggles, etc.).CautionIf the glass of the pH electrode breaks, there is a danger of cutsfrom the splinters of glass!NoteWe do not recommend unscrewing the sensor from the sensorconnection cable when changing the electrode. Otherwise, moistureand/or dirt can get into the plug connection where they can causecontact problems.If you would like to disconnect the sensor from the sensor connectioncable, please note the following points:• Before disconnecting the sensor from the SAC<strong>IQ</strong> (<strong>SW</strong>) sensorconnection cable, remove any larger pieces of contamination fromthe sensor, particularly in the area of the plug connection (brush itoff in a bucket of tapwater, wash it off with a hose or wipe it off witha cloth).• Unscrew the sensor from the SAC<strong>IQ</strong> (<strong>SW</strong>) sensor connection cable.• Always place a protective cap on the plug head of the sensor and onthe SAC<strong>IQ</strong> (<strong>SW</strong>) sensor connection cable so that no moisture or dirtcan get into the contacting surfaces.• In corrosive environments close the dry socket of the sensorconnection cable with the SAC<strong>IQ</strong>-Plug protective screw cap in orderto protect the electrical contacts from corrosion. The protective capis available as an accessory (see section 6.2 GENERALACCESSORIES). It is included in the standard scope of delivery of theSAC<strong>IQ</strong> <strong>SW</strong> sensor connection cable.ba15324e06 12/20055 - 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!