when it counts 2.1.6.A. Position #1(Normal) is for normal operation.FIG 9 Gas Valve ON P12.1.6.B. Position #2(Adverse) is for adverse conditions such as fouling or short stroking.FIG 10 Gas Valve ON P2 AdverseCAUTION: The rifle should NOT be operated in Position #2 (Adverse) for an extended period of time. As soon as normalfunction returns, the gas valve should be rotated to Position #1 (Normal). Continued operation with the gas valve inPosition #2 (Adverse) will increase recoil and place unnecessary stress on the rifle. Having to operate the rifle in Position#2 (Adverse) is an indicator that the rifle needs maintenance.www.sigsauer.com 27