12.07.2015 Views

Trianco Premier Kitchen HE Oil Boilers 50,90100 & 125 ... - BHL.co.uk

Trianco Premier Kitchen HE Oil Boilers 50,90100 & 125 ... - BHL.co.uk

Trianco Premier Kitchen HE Oil Boilers 50,90100 & 125 ... - BHL.co.uk

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Balanced Flue Systems(optional extra)The <strong>Trian<strong>co</strong></strong> balanced flue system offers much greaterflexibility for siting, the boiler <strong>co</strong>mpared with a<strong>co</strong>nventional chimney. The only requirement is for asuitable outside wall to fit the horizontal dischargeterminal or, alternatively, a single storey roof for a verticaldischarge.In addition to the siting benefit, the performance ofbalanced flue boilers is virtually unaffected by high wind<strong>co</strong>nditions since the wind pressures are applied equallyto both air intake and flue gas discharge, thus creating abalanced <strong>co</strong>ndition.Whereas some balanced flue boilers rely on case sealingto achieve a room seal, <strong>Trian<strong>co</strong></strong> boilers have a sealed airduct system which maintains the room sealedperformance even when the casing door is removed forburner <strong>co</strong>mmissioning or adjustments.The use of the balanced flue principle also enhances theoverall thermal efficiency of the boiler since the in<strong>co</strong>mingair extracts waste heat from the flue and returns it aspre-heated air to the burner where it aids <strong>co</strong>mbustion.INSTALLATION NOTES(a) Balanced-flue <strong>co</strong>ndensing boilers are designedto operate at low noise levels. During operation,a plume of <strong>co</strong>ndensation will be produced atcertain times from the terminal. When positioning,these factors should be taken into <strong>co</strong>nsiderationto ensure that they do not cause a nuisance toneighbouring properties. It should also bepositioned to avoid the products of <strong>co</strong>mbustionfrom entering the building.(b) Keep the terminal clear of infrared sensingdevices such as these used to <strong>co</strong>ntrol securitylighting.(c) Positioning of flues under bal<strong>co</strong>nies and carportsshould be avoided.(d) As the system operates under positive pressure,it is essential that all flue joints are sealed <strong>co</strong>rrectly.(e) Only 28 sec. Kerosene Class C2 to BS 2869 ispermitted for use with this appliance.Note <strong>Trian<strong>co</strong></strong> balanced flue kits have been designedexclusively for use with <strong>Trian<strong>co</strong></strong> boilers and as such,<strong>co</strong>mpatibility with other makes of boiler cannot beguaranteed.POMBNH. JC. DB<strong>HE</strong>AGFKFLRECOMMENDED MINIMUM DISTANCESFOR TERMINAL POSITIONAppliance burner type - Pressure JetMinimum distances to terminals in millimetres as measured from top of chimneyor the rim of a low level discharge openingA Directly below an opening, air brick, window etc 600B Horizontally to an opening, air brick, window etc 600C Below a gutter, eaves or bal<strong>co</strong>ny with protection 75D Below a gutter or bal<strong>co</strong>ny without protection 600E From vertical sanitary pipework (*600) 300F From an internal or external <strong>co</strong>rner (*600) 300G Above ground or bal<strong>co</strong>ny level (*600) 300H From a surface or boundary facing the terminal 600J From a terminal facing the terminal 1200K Vertically from a terminal on the same wall 1<strong>50</strong>0L Horizontally from a terminal on the same wall 7<strong>50</strong>M Above the highest point of an intersection with the roof 600N From a vertical structure on the side of the terminal 7<strong>50</strong>O Above a vertical structure less than 7<strong>50</strong>mm from the side of the terminal 600P From a ridge terminal to a vertical structure on the roof 1<strong>50</strong>0Note (1)Note (2)Note (3)*S<strong>co</strong>tland 1990The terminal should be positioned so as to avoidproducts of <strong>co</strong>mbustion entering the building.If the terminal is less than 2 metres above theground level, bal<strong>co</strong>ny or place to which anyperson has access, the terminal must beprotected by a guard.The flue must be positioned so that it does notcause nuisance and permits the dispersal of<strong>co</strong>mbustion products.FIG. 13 TERMINAL POSITION16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!