<strong>Topaz</strong> <strong>T100si</strong>Fault FindingIMPORTANT: Switch off the electricity at the mains supply and remove the circuit fuse beforeattempting any fault finding inside the unit.Problem/Symptom Cause action/Cure1 Showerinoperable.1.1 Interrupted powersupply.1.2 Unit malfunction.1.1.1 Blown fuse or circuit breaker. Checksupply. Renew or reset fuse or circuit breaker. Ifit fails again, consult a qualified electrician.1.1.2 Power cut? Check other appliances and ifnecessary, contact local Electric Supply Co.1.2.1 Have unit checked by suitably qualifiedelectrician or contact Customer Service.2 Water flows whenisolating switch isswitched on.2.1 Ribbon cable is notconnected.2.2 Unit malfunction.2.1.1 Switch off the electric supply, remove theshower cover and plug in ribbon cable.2.2.1 Contact Customer Service.3 Water too hot.3.1 Temperature controlincorrect setting.3.2 Unit malfunction.3.1.1 Turn anti-clockwise.3.2.1 Contact Customer Service.4 Unstable showertemperature orflow.4.1 Blockages.4.2 Loose ribbon cableconnection.4.3 Unit malfunction.4.1.1 Clean showerhead. Check inlet filter.4.2.1 Check connections on PCB.4.3.1 Contact Customer Service.5 Water too cool orcold.5.1 Temperature controlincorrect setting.5.2 Unit malfunction.5.3 Safety cut-outoperated.5.1.1 Turn clockwise.5.2.1 Contact Customer Service.5.3.1 The thermal safety cut-out device hasoperated. Have unit checked by suitablyqualified electrician or contact Customer Service.6 ‘LP’ flashing ondisplay.6.1 Water pressure hasdropped below minimumrequired.6.2 Blockage in outlet.6.3 Loose connection onPCB.6.4 Blocked connectingtube to pressure switch.6.1.1 Wait until water pressure has returned tonormal.6.2.1 Check and clean outlet and/orshowerhead.6.3.1 Check connection on PCB from pressureswitch.6.4.1 Make sure the tube from solenoid valve topressure switch is not kinked or blocked.29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!