<strong>Topaz</strong> <strong>T100si</strong>Electrical requirementsWARNING!This appliance must beearthedThe installation, supply cable and circuitprotection must conform with BS7671 (IEEwiring regulations) and be sufficient for theamperage required.The following notes are for guidance only:1 The shower must only be connected to a230-240V ac supply. If you are installing ashower with a kilowatt rating above 9kW, itis advisable to contact the local electricitysupply company.Shepperton Park,<strong>Triton</strong> Road, Nuneaton,Warwickshire, CV11 4NRPull cordisolating switchFig.3Fig.4 schematic of installation circuit1.1 The electrical rating of the shower is shownon the rating label (fig.3) within the unit.2 Before making any sort of electricalconnection within the installation makesure that no terminal is live. If in anydoubt, switch off the whole installation atthe consumer unit.3 The shower must be connected to its ownindependent electrical circuit. IT MUSTNOT be connected to a ring main, spur,socket outlet, lighting circuit or cookercircuit.3.1 The electrical supply must be adequatefor the loading of the unit and existingcircuits.4 Check your consumer unit (main fuse box)has a main switch rating of 80A or aboveand that it has a spare fuse way which willtake the fuse or miniature circuit breaker(mcb) necessary for the shower (fig.4).4.1 If your consumer unit has a rating below80A or if there is no spare fuse way, thenthe installation will not be straightforwardand may require a new consumer unitserving the house or just the shower.4.2 You will need to contact the localelectricity company. They will check thesupply and carry out what is necessary.They will also check the main bonding.5 The earth continuity conductor of theelectrical installation must be effectivelyconnected electrically to all exposed metalTable ARCD(can be part ofconsumer unit)ShowerunitCircuit protectionunitcartridgerating mcb fuse7.0kW 30/32A 30AFuse orMCB80A or 100Amain switchConsumerunitMetertailsMeterIncomingsupplyfuse7.5kW 32A 35A8.0kW 40A 35A8.5kW 40A 45A9.0kW 40A 45A9.5kW 40/45A 45A10.5kW 45A 45A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!