12.07.2015 Views

Download the manual - Drolet

Download the manual - Drolet

Download the manual - Drolet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Columbia Installation and Operation Manual7.3 Floor protectorIf <strong>the</strong> stove is to be installed on top of a combustible floor, it must be guarded by a noncombustible material as shown on figure above (see <strong>the</strong> dotted line area).CANADAFLOOR PROTECTOR*USAG 8’’ (203 mm) – Note 1 N/A (Canada only)H 8’’ (203 mm) N/A (Canada only)I 18’’ (457 mm)From door opening16’’ (406 mm)From door openingJ N/A (USA only) 8’’ (203 mm)M 8’’ (203 mm) N/A (Canada only)N N/A (USA only) Note 2*Steel with a minimum thickness of 0.015’’ (0.38 mm) or ceramic tiles sealed toge<strong>the</strong>rwith grout. No protection is required if <strong>the</strong> unit is installed on a non-combustible floor(ex: concrete).Note 1: The floor protection at <strong>the</strong> back of <strong>the</strong> stove is limited to <strong>the</strong> stove’s requiredclearance if such clearance is smaller than 8 inches (203 mm).Note 2: Only required under <strong>the</strong> horizontal section of <strong>the</strong> connector. Must exceed eachside of <strong>the</strong> connector by at least 2 inches (51 mm).32