Columbia Installation and Operation Manual8.2.3 Masonry ChimneysThe stove may also be connected to amasonry chimney, provided <strong>the</strong>chimney complies with <strong>the</strong> constructionrules found in <strong>the</strong> building codeenforced locally. The chimney musthave ei<strong>the</strong>r a clay liner or a suitablylisted stainless steel liner. If <strong>the</strong>masonry chimney has a square orrectangular liner that is larger in crosssectional area than a round 6” flue, itshould be relined with a suitably listed6” stainless steel liner. Do notdownsize <strong>the</strong> flue to less than 6” unless<strong>the</strong> venting system is straight andexceeds 25 feet in height. Whenpassing through a combustible wall, <strong>the</strong>use of an insulated listed thimble isrequired.8.3 Minimum Chimney HeightThe top of <strong>the</strong> chimney should betall enough to be above <strong>the</strong> airturbulence caused when windblows against <strong>the</strong> house and itsroof. The chimney must extend atleast 1 m (3 ft.) above <strong>the</strong> highestpoint of contact with <strong>the</strong> roof, andat least 60 cm (2 ft.) higher thanany roof line or obstacle within ahorizontal distance of 3 m (10 ft.).37