Optional PCOR Housing<br />

(continued)<br />

<strong>Series</strong> <strong>51</strong> <strong>Hydraulic</strong> <strong>Proportional</strong> <strong>Controls</strong><br />

Service Manual<br />

PCOR<br />

Assembly<br />

1. If previously removed, use a 3mm internal hex wrench to install orifices (U6, U7).<br />

Torque to 6 N•m [4 lbf•ft].<br />

2. Using petroleum jelly to retain them, install new interface O-rings (N24P, N82).<br />

3. Position PCOR on multiblock. Install screws (N29). Torque using a 5 mm internal hex<br />

wrench to 16 N•m [12 lbf•ft].<br />

4. Lubricate and install spool and spring guide assembly (N20).<br />

5. Install spring (N18) to cavity.<br />

6. Lubricate and install new O-ring (N16J). Install adjustment plug (Z00).<br />

7. Using a 1-1/16 inch hex wrench, install locknut (N14). Do not torque until after PCOR<br />

adjustment. Refer to page 13 for instructions.<br />

8. Lubricate and install a new O-ring (N23A). Using a 1 inch hex wrench, install plug<br />

(N23). Torque to 40 N•m [30 lbf•ft].<br />

9. Lubricate and install new O-rings (N27A). Using a 1/8 inch internal hex wrench, install<br />

and torque plugs (N27) to 7 N•m [4 lbf•ft].<br />

11009446 • Rev AC • November 2010<br />