installation instructions cuh heavy duty unit heater - LUCKINSlive

installation instructions cuh heavy duty unit heater - LUCKINSlive

installation instructions cuh heavy duty unit heater - LUCKINSlive

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PRINCIPLES OF OPERATIONUpon a call for heat from the remote low level oroptional <strong>unit</strong> mounted thermostat, the <strong>unit</strong> fan motorand heating elements will be energized and remainON until temperature reaches setting of thermostat; atwhich time the heating elements will be de-energized.The fan motor will continue to run and purge the<strong>heater</strong> casing of residual heat until the setting of fanoverride is reached, then the fan motor will be deenergized.For those <strong>unit</strong>s with a factory installed two speed fanswitch, the <strong>unit</strong> as shipped from the factory is set tolow speed. Customer option to set to high speed. Forthose <strong>unit</strong>s available with subdivided circuits, theoptional two stage thermostat will, upon a call forheat, energize fan motor and the first stage heatingelement. Should temperature continue to fall, thethermostat will energize the second stage heatingelement.Upon a rise in temperature towards the setting of thethermostat, the two stages of heating elements shallbe de-energized in reverse sequence.The fan motor shall continue to run and purge the<strong>heater</strong> casing of residual heat until setting of fanoverride is reached, then the fan motor will be deenergized.The optional <strong>unit</strong> mounted de-stratification thermostatwill energize the <strong>unit</strong> <strong>heater</strong> fan motor upon a rise intemperature above its setting.When the <strong>unit</strong> mounted stratification thermostat closeson a temperature rise and at the same time the floorthermostat calls for heat, the motor will be energizedimmediately and the heating element will be energized,as previously described.The automatic reset safety high limit shall de-energizethe heating elements and control circuits should thetemperature exceed the setting of this device. The fansafety override will energize the fan motor any time thesetting of this device is exceeded so as to purge <strong>heater</strong>casing of excess residual heat.When the fan switch is placed in the ON position (forsummer air circulation), the <strong>unit</strong> <strong>heater</strong> fan motor will beenergized.NOTE:The wall thermostat should be set to the OFFposition during this mode of operation (<strong>unit</strong>s withcontactors).For thermostats equipped with an integral fan switch,place the switch in the HEAT or AUTO position , foroperation of the fan and elements which will then beunder control of the thermostat as described above.When switch is placed in the OFF position, the <strong>unit</strong> willbe de-energized. When switch is placed in the FANposition, elements shall be de-energized and fan shallbe immediately energized.SPECIFICATIONHeaterFan motorAir VolMax Mtg Ht (m)ThrowWtCat No kW Volts Phase Amp/phWattrpmm3/hrHorizVertmkgsCUH-03-1CUH-03-3CCUH-05-1CUH-05-3CCUH-07-3CCUH-10-3CCUH-15-3CCUH-20-3CCUH-25-3CCUH-30-3CCUH-40-3C3.33.35.05.07.510.015.020.025.030.040.02304002304004004004004004004004001P3P&N1P3P&N3P&N3P&N3P&N3P&N3P&N3P&N3P&N13.44.520.56.810.213.620.427.234.040.854.46.06.06.06.015.015.038.062.062.062.0186.01550155015501550155015501550155015501550155068068068068011901190187034003400340052002.82.82.82.83.03.03.43.73.73.73.72.82.82.82.83.74.36.16.76.76.17.33.73.73.73.76.76.79.89.813.712.216.71212121223233055555555Page 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!