13.07.2015 Views

Collaborative Intravenous Nursing Service (CINS) Guidelines

Collaborative Intravenous Nursing Service (CINS) Guidelines

Collaborative Intravenous Nursing Service (CINS) Guidelines

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Decontaminate hands. Put on sterile gloves connect the needle / filter straw to the syringe With a piece of sterile gauze pick up the 0.9% sodium chloride ampule, draw up 10ml.Repeat for Heparinised saline. If a needle is used dispose directly into the sharpscontainer. Place the filled syringes on the sterile field. Prime the non-coring needle device including its tubing with saline and clamp extensiontube, remove syringe. Remove local anaesthetic cream if required and locate septum of TIVAD by palpation,remove gloves. Decontaminate hands and put on new sterile gloves. Place dressing towel as near as possible to TIVAD site. Clean the skin covering the TIVAD with gauze soaked in Chlorhexidine Gluconate 2% in70% Isopropyl alcohol or Chlorhexidine Gluconate 2% in 70% Isopropyl alcoholimpregnated applicator Allow to dry Remove needle cover from non-coring needle device. Insert the non-coring needle at 90-degree angle through the skin into the septum of the TIVAD until the needle comes intocontact with the metal backing. Needle free device must be cleaned prior to reattaching syringe – thoroughly clean thehub of the needle free system with 2% Chlorhexidine impregnated wipe or sterile gauzesoaked in 2% Chlorhexidine, rubbing the top of the needle free connector to the sides.This should be done 3 times over a period of 30 seconds. Allow to dry. Attach empty 10ml syringe unclamp and aspirate 3-5ml of blood. Clamp catheter andremove the syringe and discard the sample. If unable to obtain blood flush the catheter asdirected below. Using a second syringe, take amount of blood required for analysis thenflush the port as directed below. Attach syringe with 0.9% Sodium Chloride (saline) and inject the flush using a push pauseaction camping as the last ml of the solution is instilled into the catheter. Remove thesyringe and discard. If there is swelling around the TIVAD site assess for correct needle placement, remove theneedle and re-access Following successful saline flush, repeat the flushing procedure using the Heparinisedsaline.60The CINs group hereby assert their moral rights tothe works herein in accordance with the Data Protection Act 1988.Policy review date 01/10/10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!