4.7 SCHEMATIC ELECTRICAL EXTERNAL CONTROLS.External electrical connections are made into the boiler via the 4 connections onthe bottom right hand side of the front panel.1. The cylinder stat connects via a two pin female.2. The room stat connects via a two-pin male.3. The power connects via a two-pin female housed in a three pin plastic cover.4. The time clock links out via a two-pin male housed in a three pin plastic cover.4.8 OIL SUPPLY.Oil supply to the burner can be via 8 or 10 mm pipe the diameter will depend uponthe length of run.Oil feed hoses used in the system must comply with ISO 7840Oil supply pipes must be level to avoid air traps and clipped at 500mm intervals13