Work the burner out from the boiler by simultaneously rotating and lifting it upand out from the top of the boiler.Once the burner is removed from the boiler it can be stripped down and cleaned asfollows.7.3 TO REMOVE AND CLEAN THE FLAME TUBE.RemoveNozzle7.5 TO REMOVE EXAMINE AND ADJUST THE ELECTRODE.7.6 TO REMOVE AND CLEAN THE PHOTOCELL.The Photocell plugs into the side of the burner and can be unplugged and wipedclean.25