13.07.2015 Views

Design Requirements for Sewage Pumping Stations - The City of ...

Design Requirements for Sewage Pumping Stations - The City of ...

Design Requirements for Sewage Pumping Stations - The City of ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>City</strong> <strong>of</strong> Wentzville, MissouriEngineering <strong>Design</strong> Criteria<strong>The</strong> junction chamber, containing the terminal board, shall be sealedfrom the motor by elastomer compression seal (O-rings). Where asealed junction chamber is not used, the motor chamber shall be fittedwith a moisture detection probe. <strong>The</strong> probe shall be connected to andactivate a warning light in the control panel.Connection between the cable conductors and stator leads shall bemade with threaded compressed type binding posts permanentlyaffixed to a terminal board and thus perfectly leak pro<strong>of</strong>.Each unit shall be provided with an adequately designed coolingsystem. When thermal radiators (cooling fins) are used, they shall beintegral to the stator housing and shall be adequate to provide thecooling required by the motor. When water jackets are used, thewater jacket shall encircle the stator housing. <strong>The</strong> water jacket shallbe provided with a separate circulation <strong>of</strong> the pumped liquid. Coolingmedia channels and parts shall be non-clogging by virtue <strong>of</strong> theirdimensions. Provision <strong>for</strong> external cooling and flushing shall beprovided. Regardless <strong>of</strong> the cooling system used, the motor must becapable <strong>of</strong> pumping under full load continuously with the water levelonly to the top <strong>of</strong> the volute. Motors with intermittent full load ratingsor motors requiring oil <strong>for</strong> cooling will not be allowed.When double shrouded impellers are used, a wear ring system shallbe installed to provide efficient sealing between the volute andimpeller. <strong>The</strong> wear ring shall consist <strong>of</strong> a stationary ring made <strong>of</strong>nitrile rubber molded with a steel ring insert which is drive fitted to thevolute inlet and rotating stainless steel ANSI 304 ring which is drivefittedto the impeller eye.When single shrouded impellers are used, the volute shall be fittedwith an adjustable replaceable front plate. <strong>The</strong> front plate shall bedesigned with a wave shaped inlet and an outward spiraling V-shapedgroove on the side <strong>for</strong>cing the impeller to shred and <strong>for</strong>ce stringysolids outward from the impeller and through the pump discharge.<strong>The</strong> volute shall be <strong>of</strong> single piece design and shall have smooth fluidpassages large enough at all points to pass any size solid which canpass through the impeller.<strong>The</strong> pump motor cable, installed, shall be suitable <strong>for</strong> submersiblepump application. Cable sizing shall con<strong>for</strong>m to NEC specifications<strong>for</strong> pump motors.<strong>The</strong>rmal sensors shall be used to monitor stator temperatures. <strong>The</strong>stator shall be equipped with three (3) thermal switches, embedded inthe end coils <strong>of</strong> the stator winding (one switch in each stator phase).<strong>The</strong>se shall be used in conjunction with and supplemental to externalmotor overload protection and wired to the control panel.4 - 21 Approved 6/10/09

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!