Connection 02.96WARNINGIncorrect connection to the mains will destroy the unit!The excitation coils of contactors and relays connected to the same mains network as theunit, or which are located in its proximity, must be wired with surge arresters, e.g. RCnetworks.The unit must not be operated via a current-operated earth-leakage circuit-breaker (DINVDE 0160).A voltage may only be applied to the unit after connecting <strong>SIMOVERT</strong> <strong>Master</strong> <strong>Drives</strong>.Swapping or shorting the dc link terminals will destroy the <strong>SIMOVERT</strong> <strong>Master</strong> <strong>Drives</strong>inverter!The units are intended for permanent connection to the mains in conformity with DIN VDE 0160 Section 6.5.2.1.PE conductor connection: minimum cross-section 10mm 2 .The units must be fused on the mains side with semiconductor fuses as detailed in Table 3.2. To avoidretroactive effects on the mains and to limit harmonics, the mains should be connected via a 2 % commutationchoke as detailed in Table 3.3. Mains plus commutation activity must be 3% u k (ac load carrying capacity ofthe dc link capacitors in the inverter). See Table 3.2 for details of order numbers for fuses.The conductor cross-sectional areas listed in Table 3.1 are maximum connectable cross-sections. The data isgiven for multicore cable.Unit order No.Ratedinput-ConductorU1/L1, V1/L2, W1/L3ConductorC/L+, D/L-Spannung Strom max. max. max. max.ConductorPE6SE70 (V) (A) mm2 AWG 1) mm2 AWG 1) mm2 AWG 1)31-7EE85-0AA0 380 to 460 149 2x120 2x4/0 2x150 2x300 70 2/032-7EE85-0AA0 380 to 460 233 2x120 2x4/0 2x150 2x300 120 4/033-8EE85-0AA0 380 to 460 326 2x240 2x500 2x300 2x600 185 35034-6EE85-0AA0 380 to 460 403 2x240 2x500 2x300 2x600 240 50036-1EE85-0AA0 380 to 460 526 2x240 2x500 2x300 2x600 300 60031-4FE85-0AA0 500 to 575 123 2x120 2x4/0 2x150 2x300 70 2/032-4FE85-0AA0 500 to 575 203 2x120 2x4/0 2x150 2x300 120 4/033-5FE85-0AA0 500 to 690 307 2x240 2x500 2x300 2x600 185 35034-2FE85-0AA0 500 to 690 366 2x240 2x500 2x300 2x600 185 35035-4FE85-0AA0 500 to 690 465 2x240 2x500 2x300 2x600 300 60032-2HE85-0AA0 660 to 690 193 2x120 2x4/0 2x150 2x300 95 3/033-5HE85-0AA0 660 to 690 307 2x240 2x500 2x300 2x600 185 35034-2HE85-0AA0 660 to 690 366 2x240 2x500 2x300 2x600 185 35035-4HE85-0AA0 660 to 690 465 2x240 2x500 2x300 2x600 300 600Table 3.1Mains connection1) American Wire Gauge3-2 ENGLISH Siemens AG 6SE7087-6AE85-0AA0<strong>Common</strong> Rectifier Operating instructions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!