13.07.2015 Views

Under Jurisdiction of Nagpur Court only - Western Coalfields Limited

Under Jurisdiction of Nagpur Court only - Western Coalfields Limited

Under Jurisdiction of Nagpur Court only - Western Coalfields Limited

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

c) Turn signal lights (left and right) on both front and reard) Fog LampsHeadlights and rear lights shall be fitted in steel protective enclosures.4.17 Guards and ShieldsAdequate guards and shields which comply with ISO 3457 shall be provided.4.18 Fire Extinguisher1 no. fire extinguisher shall be provided suitably mounted in a heavy duty bracket for ease <strong>of</strong>removal. The extinguisher shall be dry powder (cartridge type) with a capacity <strong>of</strong> 5 kg and shallcomply with Indian Standard IS: 2171.4.19 Water Sprinkling SystemThe water sprinkling system should be provided with centrifugal water pump driven by ahydraulic motor through flexible coupling. The suction & discharge pipe should be <strong>of</strong> adequatediameter with suitable valves. The sprinkling should be pressurised and constant sprinklingvelocity is to be maintained by centrifugal pump. In addition to pressurised sprinkling, provision<strong>of</strong> gravity sprinkling should also be provided through perforated manifold connected to tankbottom. Self-filling provision from outside reservoir or pond by connecting the pump suctionthrough armoured hose with foot valve should be provided. The system should be equipped withquick connecting adopter(s) & suitable nozzles for fire fighting unit adoption.4.20 Automatic Fire Detection and Suppression System:Automatic Fire Detection and Suppression System shall be provided and suitably mounted in theEquipment. The materials and chemicals to be used in Fire Detection and Fire Suppression Systemto be supplied with the equipment. The type and make <strong>of</strong> the system must be approved by DGMS.5. Ancillary Equipment And Other RequirementsThe following shall be provided on the dumper:a) Front and rear tow hooks and two lifting loops.b) Pressurised radiator capc) Head light high-beam indicator.d) Water separators in air lines.e) Rock ejector bars between each set <strong>of</strong> dual rear wheelsf) Front pressurised sprinkling6. Safety DevicesThe following Safety devices shall be provided on the dumper:a) Mechanical Steering Locking Device.b) Seat Belt for Operatorc) Blind Spot Mirrord) Audio Visual Reverse Alarm (DGMS Approved)e) Fire/ Heat Resistant Hydraulic Hoses in place <strong>of</strong> ordinary Hoses.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!