- Page 2 and 3: WARNINGS ON REFRIGERANT LEAKAGEChec
- Page 4 and 5: SAFETY CAUTIONThe important content
- Page 6 and 7: WARNINGInsulator checkVentilationBe
- Page 8 and 9: 4. Tools(1) Required Tools for R410
- Page 10 and 11: 1. DESIGN METHODS1-1. System Overvi
- Page 12 and 13: TypeAppearanceModel nameCapacityran
- Page 14 and 15: 1-1-5. Remote ControllerNameModelna
- Page 16 and 17: NameModelnameAppearanceApplicationP
- Page 20 and 21: 20ColorindicationRED : REDWHI : WHI
- Page 22 and 23: 221 31 2 2ReactorREDWHIWHIIndoor un
- Page 24 and 25: 24REDIndoor unitWHIFlow selectoruni
- Page 26 and 27: 26GRN & YELHeat exchangerGRN & YELP
- Page 28 and 29: 28Indoor unitearth screwREDWHIR(L)
- Page 30 and 31: 30FlowSelector unitEarth screwColor
- Page 32 and 33: 2-3. Connection of PMV KitModel: RB
- Page 34 and 35: 2-way Air Discharge Cassette TypeMo
- Page 36 and 37: Under Ceiling TypeModel MMC-AP 0151
- Page 38 and 39: 3-5. Parts Layout in Outdoor UnitRe
- Page 40 and 41: SET DATASETTINGTESTUNIT No.R.C.No.[
- Page 42 and 43: [In Cooling operation]REQUIREMENT
- Page 44 and 45: Right/Left air direction adjustment
- Page 46 and 47: 3-11. InstallationInstallation loca
- Page 48 and 49: 48If you do not plan to use the uni
- Page 50 and 51: Confirmation and checkWhen a error
- Page 52 and 53: 4-2. Explanation of Functional Part
- Page 54 and 55: 5. SWITCH (SW08) SET UP OF THE OUTD
- Page 56 and 57: No.ItemOutline of specificationsRem
- Page 58 and 59: No.ItemOutline of specificationsRem
- Page 60 and 61: No.ItemOperation explanation and ap
- Page 62 and 63: Other cautions1. Cooling operation
- Page 64 and 65: Table: Function selecting item code
- Page 66 and 67: 7-1-2. Applied Control in Indoor Un
- Page 68 and 69:
n Leaving-ON prevention control[Fun
- Page 70 and 71:
7-2-2. Placing positionInstall this
- Page 72 and 73:
[Expansion function]Outdoor unitLoc
- Page 74 and 75:
7-2-6. Night Operation (Sound Reduc
- Page 76 and 77:
7-2-8. Error Output Controln Featur
- Page 78 and 79:
8-3. Effect of Connecting PMV Kit w
- Page 80 and 81:
Check list 1• Using the “Check
- Page 82 and 83:
829-4-3. Address Setup ProcedureIn
- Page 84 and 85:
84Note 1)When setting the line addr
- Page 86 and 87:
86In case of increase the address-u
- Page 88 and 89:
9-5-2. Operation from remote contro
- Page 90 and 91:
9-6. Test Operation Check9-6-1. Fan
- Page 92 and 93:
In case of wireless remote controll
- Page 94 and 95:
(NOTE 1)Criteria for judging differ
- Page 96 and 97:
1. Cooling test operation functionT
- Page 98 and 99:
4. Individual start/stop (ON/OFF) i
- Page 100 and 101:
2. Clearing from the interface P.C.
- Page 102 and 103:
9-7-4. Pulse Motor Valve (PMV) Forc
- Page 104 and 105:
9-7-7. Fan Operation Check in Outdo
- Page 106 and 107:
9-7-9. Indoor Fan Operation Check F
- Page 108 and 109:
10. TROUBLESHOOTING10-1. Troublesho
- Page 110 and 111:
WiredremotecontrollerdisplayCheck c
- Page 112 and 113:
New check code1. Difference between
- Page 114 and 115:
In case of central remote controlle
- Page 116 and 117:
10-4. Check Code and Check Position
- Page 118 and 119:
Check codeWiredOutdoor 7-segment di
- Page 120 and 121:
Check codeWired Outdoor 7-segment d
- Page 122 and 123:
Check codeWired Outdoor 7-segment d
- Page 124 and 125:
Error detected by TCC-LINK central
- Page 126 and 127:
Check codeCheck code nameCause of o
- Page 128 and 129:
Check codeCheck code nameCause of o
- Page 130 and 131:
Check codeCheck code nameCause of o
- Page 132 and 133:
Check codeCheck code nameCause of o
- Page 134 and 135:
Check codeCheck code nameCause of o
- Page 136 and 137:
Check codeCheck code nameCause of o
- Page 138 and 139:
Check codeCheck code nameCause of o
- Page 140 and 141:
Check code[P15] / [AE](TCC-L / AI-N
- Page 142 and 143:
Check codeCheck code nameCause of o
- Page 144 and 145:
Display ACN30SW06D600CN31SW01SW07CN
- Page 146 and 147:
2. Data display of outdoor unit inf
- Page 148 and 149:
5. Outdoor EEPROM check code displa
- Page 150 and 151:
15010-8. Pressure Sensor Output Che
- Page 152 and 153:
152Central control Xremote controll
- Page 154 and 155:
154Central control Xremote controll
- Page 156 and 157:
156Central control Xremote controll
- Page 158 and 159:
158DC fan outputPMV outputDC fan re
- Page 160 and 161:
MCC-15202-way Air Discharge Cassett
- Page 162 and 163:
11-2. Outdoor UnitPositions to be c
- Page 164 and 165:
Fan P.C. board (MCC-1531) (Fan IPDU
- Page 166 and 167:
12. BACKUP OPERATIONS (EMERGENCY OP
- Page 168 and 169:
14. REPLACING PROCEDURE OF PARTSNo.
- Page 170 and 171:
No.Part nameProcedureRemarks2Invert
- Page 172 and 173:
No.Part nameProcedureRemarks3How to
- Page 174 and 175:
No.Part nameProcedureRemarks3How to
- Page 176 and 177:
No.Part nameProcedureRemarks5Compre
- Page 178 and 179:
No.Part nameProcedureRemarks6Liquid
- Page 180 and 181:
No.Part nameProcedureRemarks8Attach
- Page 182 and 183:
15. P.C. BOARD15-1. Indoor Unit15-1
- Page 184 and 185:
Procedure 2 : Exchange of P.C. boar
- Page 186 and 187:
Record the contents of the followin
- Page 188 and 189:
16. EXPLODED VIEWS AND PARTS LIST16
- Page 190 and 191:
16-1-3. Controller for Air Conditio
- Page 192 and 193:
16-2.PMV KitRBM-PMV-0361E, RBM-PMV-