- Page 2 and 3: WARNINGS ON REFRIGERANT LEAKAGEChec
- Page 4 and 5: SAFETY CAUTIONThe important content
- Page 6 and 7: WARNINGInsulator checkVentilationBe
- Page 8 and 9: 4. Tools(1) Required Tools for R410
- Page 10 and 11: 1. DESIGN METHODS1-1. System Overvi
- Page 12 and 13: TypeAppearanceModel nameCapacityran
- Page 14 and 15: 1-1-5. Remote ControllerNameModelna
- Page 16 and 17: NameModelnameAppearanceApplicationP
- Page 18: 18Indoor unitR(L) S(N)Earth screwSy
- Page 21 and 22: 21Indoor unitearth screwR(L) S(N)RE
- Page 23: 23ColorindicationRED : REDWHI : WHI
- Page 27 and 28: 27Indoor unitearth screwAC INR(L) S
- Page 29 and 30: 29REDIndoor unitearth screwWHIR(L)
- Page 31 and 32: 2-2. Outdoor UnitModel: MCY-MAP0401
- Page 33 and 34: 3. PARTS RATING3-1. Indoor Unit4-wa
- Page 35 and 36: Concealed Duct Standard TypeModel M
- Page 37 and 38: 3-2. Outdoor UnitModel MCY-MAP0401H
- Page 39 and 40: SET DATASETTINGTESTUNIT No.R.C.No.W
- Page 41 and 42: 41Operation sectionPush each button
- Page 43 and 44: Based on the shape or arrangement o
- Page 45 and 46: Floor Standing TypeAdjustment of ai
- Page 47 and 48: High Wall Type(Model : 1H series)
- Page 49 and 50: The slot provided at side surface o
- Page 51 and 52: 4. REFRIGERANT PIPING SYSTEMATIC DR
- Page 53 and 54: 4-3. Indoor UnitLiquid sideGas side
- Page 55 and 56: 6. CONTROL OUTLINE6-1. Indoor Unit6
- Page 57 and 58: No.ItemOutline of specificationsRem
- Page 59 and 60: 6-2. Outdoor Unit6-2-1. Operation S
- Page 61 and 62: No.ItemOperation explanation and ap
- Page 63 and 64: 7. APPLIED CONTROL7-1. Indoor Unit7
- Page 65 and 66: TYPEItem code [10]Setup data0000000
- Page 67 and 68: n Ventilating fan control from remo
- Page 69 and 70: 7-2. Outdoor Unit7-2-1. Applied Con
- Page 71 and 72: 7-2-4. Power Peak-cut Controln Feat
- Page 73 and 74: 7-2-5. External master ON/OFF contr
- Page 75 and 76:
7-2-7. Operation Mode Selection Con
- Page 77 and 78:
8. PMV KIT OUT LINE8-1. Purpose of
- Page 79 and 80:
9. TEST OPERATION9-1. Procedure and
- Page 81 and 82:
9-3. Check at Main Power-ONAfter tu
- Page 83 and 84:
838. When address setup has finishe
- Page 85 and 86:
85• To change all the indoor addr
- Page 87 and 88:
9-5. Troubleshooting in Test Operat
- Page 89 and 90:
Incorrect wiring example(Fig. 1)Rem
- Page 91 and 92:
Wireless remote controller(Except 4
- Page 93 and 94:
2. Test operationSTARTTest operatio
- Page 95 and 96:
9-7. Service Support Function9-7-1.
- Page 97 and 98:
3. Batch start/stop (ON/OFF) functi
- Page 99 and 100:
9-7-2. Error Clearing Function1. Cl
- Page 101 and 102:
9-7-3. Remote Controller Distinctio
- Page 103 and 104:
9-7-6. Solenoid Valve Forced Open/C
- Page 105 and 106:
8-7-8. Manual Adjustment Function o
- Page 107 and 108:
9-7-11. Monitor Function of Remote
- Page 109 and 110:
10-2. Check MethodIf an trouble occ
- Page 111 and 112:
Check codeWireless remote controlle
- Page 113 and 114:
10-3. Troubleshooting by Check Disp
- Page 115 and 116:
In case of AI-NET central remote co
- Page 117 and 118:
117Check codeWired Outdoor 7-segmen
- Page 119 and 120:
Check codeWired Outdoor 7-segment d
- Page 121 and 122:
Check codeWiredOutdoor 7-segment di
- Page 123 and 124:
Check codeWired Outdoor 7-segment d
- Page 125 and 126:
10-5. Diagnosis Procedure for Each
- Page 127 and 128:
Check codeCheck code nameCause of o
- Page 129 and 130:
Check codeCheck code nameCause of o
- Page 131 and 132:
Check codeCheck code nameCause of o
- Page 133 and 134:
Check codeCheck code nameCause of o
- Page 135 and 136:
Check codeCheck code nameCause of o
- Page 137 and 138:
137Check code[P04] / [21](TCC-L / A
- Page 139 and 140:
Check codeCheck code nameCause of o
- Page 141 and 142:
Check codeCheck code nameCause of o
- Page 143 and 144:
Check codeCheck code nameCause of o
- Page 145 and 146:
1. Data display of system informati
- Page 147 and 148:
3. Data display of outdoor cycleSW0
- Page 149 and 150:
n Pressure sensor characteristics
- Page 151 and 152:
151n Ps sensor characteristics0 to
- Page 153 and 154:
153Central control Xremote controll
- Page 155 and 156:
155Central control Xremote controll
- Page 157 and 158:
157Central control Xremote controll
- Page 159 and 160:
159Power transformer(Primary side)(
- Page 161 and 162:
11-1-3. Optional Connector Specific
- Page 163 and 164:
Inverter P.C. board (MCC-1535) [IPD
- Page 165 and 166:
11-2-1. Outdoor Interface P.C. Boar
- Page 167 and 168:
13. REPLACING COMPRESSOR13-1. Compr
- Page 169 and 170:
No.Part nameProcedureRemarks2Invert
- Page 171 and 172:
No.Part nameProcedureRemarks3How to
- Page 173 and 174:
No.Part nameProcedureRemarks3How to
- Page 175 and 176:
No.Part nameProcedureRemarks4Fan mo
- Page 177 and 178:
No.Part nameProcedureRemarks5Compre
- Page 179 and 180:
No.Part nameRemarks7Parts positions
- Page 181 and 182:
Refrigerant Recovery in Outdoor Uni
- Page 183 and 184:
Method 2Before exchange, it is impo
- Page 185 and 186:
Procedure 3 : Writing-in of setup c
- Page 187 and 188:
15-2. Outdoor Unit15-2-1. Printed C
- Page 189 and 190:
16-1-2. Refrigeration Circuit16, 20
- Page 191 and 192:
16-1-4. Refrigeration Circuit Diagr
- Page 193: