13 Adjustment and CalibrationMeasuringBy pressing the key the user can select between all available channels of the HDM97Pocket .These channels are• Conductivity and temperature Display "CD/TEMP"• Temperature Display "TEMP" (if enabled)• Pressure Display "PRES" (only HDM97BP and HDM97BO• pH Display "PH" (only HDM97BP, if enabled)Conductivity and temperature measurementIn this mode the display shows "CD/TEMP" in the upper line, the temperature value in the middle line andthe conductivity value in the bottom line.By pressing the keythe user can choose the temperature coefficient.Temperature CoefficientsThis is a topic that is frequently misunderstood and often neglected in hemodialysis.A solution’s conductivity will change according to temperature. With increasing temperatures, the measuredsolution’s conductivity will increase, too. To achieve meaningful measurement results, the conductivityvalue displayed is compensated to 25°C. In other words, the display is always converted to a solutiontemperature of 25°C. The temperature coefficient which the displayed value is compensated with isexpressed as %/°C. Unfortunately however, different solutions also have different temperature coefficients.To achieve an exact display, the instrument will have to be adjusted to the temperature coefficient of thecurrent solution. The average temperature coefficient for dialysates is 2.07 %/°C.Listed below are the temperature coefficients used by most major hemodialysis machine manufacturers. Werecommend that you double check this data with documentation from your machine’s manufacturerDisplay Machine Manufacturer Temperature CoefficientBAXTER Baxter (Europe Machines) 2,20 %/KBELLCO Bellco 2,10 %/KB.BRAUN B.Braun 2,10 %/KFRESENI Fresenius 2,10 %/KGAMBRO Gambro (AK-Type Machines) 2,07 %/KGAMBRO Gambro Phoenix 2,07 %/KHOSPAL Hospal 2,07 %/KNikkisoNIK BIC Bicarbonate Conductivity 2,20 %/KNIK ALL Gesamt- Conductivity 2,05 %/KSTANDARD2,07 %/KUSER TC(Your choice)For naturally occurring solutions, a value of 1.97 %/°C is frequently used. Many measuring devices notspecially tailored to dialysis will use this value.The calculation below shows the drastic effects of an incorrect temperature coefficient.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!