13.07.2015 Views

User's Manual for CM6G - Yokogawa

User's Manual for CM6G - Yokogawa

User's Manual for CM6G - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6-3Standard Flow Sheet1. Town Gas Application (Standard Type)<strong>CM6G</strong>-S6200, S6210, S6300, S6310, S6400, S6410No. Item1-1 Calorie detector1-2 Solenoid valve1-3 Orifice assembly1-4 Differential pressure transmitter (air)1-5 Differential pressure transmitter (gas)1-6 Computing station2-1 Air set2-2 Pressure reducing valve2-3 Pressure gauge2-4 Preheating chamber2-5 One touch couplerNo. Item3-1 Line filter3-2 Pressure gauge3-3 Flowmeter3-4 Pressure reducing valve3-5 Pressure gauge3-6 Pressure reducing valve3-7 Diaphragm pump (when specified)3-8 Pressure reducing valve (when specified)4-1 Pressure reducing valveNo. Item5-1 Density meter detector (when specified)5-2 Density meter converter (when specified)5-3 Flowmeter <strong>for</strong> density meter (when specified)6-1 Standard gas cylinder (supplied by customer)6-2 Standard gas cylinder (supplied by customer)7-1 Pressure reducing valve <strong>for</strong> cylinder (optional)7-2 Pressure reducing valve <strong>for</strong> cylinder (optional)V1...16 Ball valve, needle valveSAMPLE GAS INSAMPLE GAS OUTOR VENTMaximum back pressureis 1.5 kPa and no pressurefluctuation is allowed.ABV-1V-4V-2 V-33-1*15-15-23-8 *33-7 *2 V-11V-5 V-6PDTV-135-33-2 3-5V-73-3V-123-4 3-61-11-2GASDP.T1-51-31-6AIRDP.T1-4V-164-12-3V-15 2-1V-142-2C2-42-5V-9V-8DV-10EFLOW-6410.aiINST.AIR IN0.3~0.7MPa50Nl/minSTD GAS IN (ZERO)7-17-26-16-2STD GAS IN (SPAN)*1: <strong>CM6G</strong>-S610 (with density meter)*2: <strong>CM6G</strong>-S630 (with diaphragm pump)*3: <strong>CM6G</strong>-S640 (with pressure reducing valve)Figure 6.2 Flow Sheet (<strong>for</strong> Town Gas)2. Town Gas Application (Quake-proof Type)<strong>CM6G</strong>-S6110No. Item1-1 Calorie detector1-2 Solenoid valve1-3 Orifice assembly1-4 Differential pressure transmitter (air)1-5 Differential pressure transmitter (gas)1-6 Computing station2-1 Air set2-2 Pressure reducing valve2-3 Pressure gauge2-4 Preheating chamber2-5 One touch couplerNo. ItemNo. Item3-1 Line filter6-1 Standard gas cylinder (supplied by customer)3-2 Pressure gauge6-2 Standard gas cylinder (supplied by customer)3-3 Flowmeter7-1 Pressure reducing valve <strong>for</strong> cylinder (optional)3-4 Pressure reducing valve 7-2 Pressure reducing valve <strong>for</strong> cylinder (optional)3-5 Pressure gauge3-6 Pressure reducing valve V1...16 Ball valve, needle valve4-1 Pressure reducing valve5-1 Density meter detector5-2 Density meter converter5-3 Flowmeter <strong>for</strong> density meter1-11-6V-1SAMPLE GAS IN A(10 to 20kPa)SAMPLE GAS OUTOR VENTDMaximum back pressureis 1.5 kPa and no pressurefluctuation is allowed.V-4V-2 V-33-15-1V-11V-5 V-6V-13P5-3DT3-2 3-5V-73-3V-123-4 3-61-2GASDP.T1-51-3V-16AIRDP.T1-4 4-12-3V-152-22-42-5V-82-1V-14BV-9C1V-10C2INST.AIR IN0.3 to 0.7MPa50Nl/minSTD GAS IN (ZERO)7-17-26-15-2FLOW-6110.ai6-2STD GAS IN (SPAN)Figure 6.3 Flow Sheet (<strong>for</strong> Town Gas)IM 11R02A01-02E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!