User's Manual for CM6G - Yokogawa

User's Manual for CM6G - Yokogawa

User's Manual for CM6G - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2-52.2.4 OptionName Part no. DescriptionProbe H7800HA Insertion length 650 mmProbe H7800HB Insertion length 1150 mmProbe H7800HC Insertion length 1650 mmFulflo filter G7043XJ Element material: PolypropylenePore size: 50 μmBody: SUS 316Connection: Rc 1/2Pressure reducing valve G7008XF Primary pressure: 15 MPa max.Secondary pressure: 0 to 200 kPaMaterial: Brass2.3 Standard Systems <strong>for</strong> Each Application2.3.1 Standard Systems <strong>for</strong> Each ApplicationApplication Measurement System specification Suffix code*Town Gas WI WithoutdensitymeterCalorific valueMJ/Nm 3WithdensitymeterSteel Mill WI WithoutdensitymeterCalorific valueMJ/Nm 3WithdensitymeterGas pressure 10 to 20 kPa: StandardGas pressure 10 kPa or under: With pumpGas pressure 100 to 600 kPa: With pressurereducing valueGas pressure 10 to 20 kPa: Quake-proofGas pressure 10 to 20 kPa: StandardGas pressure 10 kPa or under: With pumpGas pressure 100 to 600 kPa: With pressurereducing valueGas pressure 8 to 15 kPa: Without preheatingGas pressure 8 to 15 kPa: With preheatingGas pressure 8 kPa or under: Without preheatingGas pressure 8 kPa or under: With preheatingGas pressure 8 to 15 kPa: Without preheatingGas pressure 8 to 15 kPa: With preheatingGas pressure 8 kPa or under: Without preheatingGas pressure 8 kPa or under: With preheating-S6200-S6300-S6400-S6110-S6210-S6310-S6410-S6500-S6600-S6700-S6800-S6510-S6610-S6710-S6810 Corresponding Suffix Code of “-S6”, gas pressure and measurement.Note: A wet sample gas in the town gas application is outside the scope of the standard specifications. Consult with <strong>Yokogawa</strong>.2.3.2 Instructions <strong>for</strong> System Selection(1) The quake-proof type gas calorimeter is always equipped with the density meter.(2) The <strong>CM6G</strong> Gas Calorimeter controls the flow rate under a constant differential pressure. Inthe calorific value measurement, if the density of a sample gas changes, a flow rate errorproportional to the reciprocal of the square root of the density of the sample gas, 1/ √ρg , will begenerated, which directly affects the calorific value. There<strong>for</strong>e, density compensation is requiredusing a density meter.For the WI measurement, a density meter is not required since the WI is a value proportional to1/ √ρg .IM 11R02A01-02E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!