13.07.2015 Views

Appendix E - Technical Specifications for Drilling Operation.pdf

Appendix E - Technical Specifications for Drilling Operation.pdf

Appendix E - Technical Specifications for Drilling Operation.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EnviroLogic Resources, Inc.4.7.1 Above-Ground MonumentThe surface of each well will be finished with a concrete surface seal no less than three (3) feet in depth.Heavy gauge metal casing at least six (6) inches in diameter (four inches in diameter large than thenominal diameter of the well casing) will be used as the security casing. This security casing will beinstalled in a hole at least 10 inches in diameter (four inches in diameter large than the nominal diameterof the security casing). The security casing will be extended a minimum of 24 to a maximum of 36inches above the land surface (no more than six (6) inches above the well casing). A locking cap on thesecurity casing will be installed that fully encloses the casing collar and the security casing will bepermanently marked with well identification in<strong>for</strong>mation and the words “Monitoring Well.” The annulusbetween the security casing and the well casing will be filled with bentonite (not cement to preventdamage from expansion and shrinkage). The well will be completed with a three feet by three feet(3x3-ft) or three (3) foot diameter concrete pad, a minimum of four (4) inches in thickness and wiremeshor steel rod rein<strong>for</strong>ced and sloped to allow water to drain away from the well in all directions.Unless watertight construction is required, a drain-hole will be installed near the base of the exposedsecurity casing. The well shall be protected from damage by three metal posts at least three inches indiameter, set in and filled with concrete. The protective posts shall be installed in a triangular arrayaround the casing and at least two feet from it. Each post shall extend at least three feet above and threefeet below the ground surface.4.7.2 Flush-Mount MonumentFlush mounted well installation will only be installed at high-traffic areas not prone to flooding or pondingconditions. The concrete surface seal shall be no less than three (3) feet in depth. Heavy gauge metalcasing at least six (6) inches in diameter (four inches in diameter large than the nominal diameter of thewell casing) will be used as the security casing. This security casing will be cemented in a hole at least10 inches in diameter (four inches in diameter large than the nominal diameter of the security casing) andwill be of one-piece construction. The security casing will be permanently marked with the monitoring12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!