Industrial Managed Switches1<strong>IGS</strong>-<strong>22416C</strong>16 Gigabit Combo + 8 100/1000Base-X SFPIndustrial Rack Mount Managed Ethernet Switch• Wide operating temperature range from -40°C to 70°C• Supports Pro-Ring system and MSTP/RSTP/STP• Supports IGMP v2/v3 (IGMP snooping support)• Supports 9K Bytes Jumbo Frame• Supports IPv6*OVERVIEW<strong>Lantech</strong> <strong>IGS</strong>-<strong>22416C</strong> is a managed redundant ring Ethernetswitches with 16xGigabit combo ports and 8x100/1000Base-XSFP ports. With completely support of Ethernet Redundancyprotocol, Pro-Ring system and MSTP/RSTP/STP (IEEE802.1s/w/D) can protect your mission-critical applications fromnetwork interruptions or temporary malfunctions with its fastrecovery technology.<strong>Lantech</strong> <strong>IGS</strong>-<strong>22416C</strong> provides advanced IP-based bandwidthmanagement which can limit the maximum bandwidth for eachIP device. User can configure IP camera and NVR with morebandwidth and limit other device bandwidth. It also supportsapplication-based QoS. Application-based QoS can set highestpriority for data stream according to TCP/UDP port number.<strong>Lantech</strong> special IP police function can only permit allowed IPaddress with MAC address to access the network. Hackercannot access the IP surveillance network without permission.It can avoid hacker from stealing video privacy data andattacking IP camera, NVR and controllers. <strong>Lantech</strong> <strong>IGS</strong>-<strong>22416C</strong>also provided advanced DOS/DDOS auto prevention. If there isany IP flow become big in short time, the switch will lock thesource IP address for certain time to prevent the attack. It ishardware based prevention, so it can prevent DOS/DDOSattack immediately and completely. <strong>IGS</strong>-<strong>22416C</strong> supportsoptional IPv6 feature, which is the next-generation Internetprotocol that provides 128-bit addresses.All functions of <strong>IGS</strong>-<strong>22416C</strong> can be managed centralized andconvenient by the Web-based interface, Telnet and console(CLI) configuration. Therefore, the switch is one of the mostreliable choice for highly-managed and Gigabit Fiber Ethernetapplication.FEATURES & BENEFITS• Supports 24 Gigabit ports with 16xGigabit combo portsand 8xGigabit SFP ports• Supports Pro-Ring system and MSTP/RSTP/STP (IEEE802.1s/w/D) for Ethernet Redundancy• Supports IP-based bandwidth management• Supports application-based QoS management• Supports IP police security function• Supports DOS/DDOS auto prevention• IGMP v2/v3 (IGMP snooping support) for filteringmulticast traffic• Supports SNMP v1/v2c/v3 & RMON & 802.1Q VLANNetwork Management• Supports 9K Bytes Jumbo Frame• Multiple notification for warning of unexpected event• Web-based ,Telnet, Console (CLI), and Windows utilityconfiguration• Support LLDP Protocol• 19 inches rack mountable design• Wide operating temperature range from -40°C to 70°C• Supports IPv6*• Support ACL, 802.1x User Authentication for securityDatasheet Version 1.0www.lantechcom.tw | info@lantechcom.tw


Industrial Managed Switches2DIMENSIONS (unit=mm)SPECIFICATIONHardware SpecificationStandardsIEEE 802.3 for 10Base-TIEEE 802.3u for 100Base-TX and 100Base-FXIEEE 802.3ab for 1000Base-TIEEE 802.z for 1000Base-XIEEE 802.3x for Flow controlIEEE 802.3ad for LACP (Link Aggregation ControlProtocol )IEEE 802.1p for COS (Class of Service)IEEE 802.1Q for VLAN TaggingIEEE 802.1D for STP (Spanning Tree Protocol)IEEE 802.1w for RSTP (Rapid Spanning TreeProtocol)IEEE 802.1s for MSTP (Multiple Spanning TreeProtocol)IEEE 802.1x for AuthenticationIEEE 802.1AB for LLDP (Link Layer DiscoveryProtocol)Physical Ports Gigabit Combo port with 10/100/1000Base-T(X) and100/1000Base-X SFP ports : 16100/1000Base-X SFP port : 8MAC Table 8kPriority Queues 4Processing Store-and-ForwardSwitch Properties Switching latency: 7 usSwitching bandwidth: 48GbpsMax. Number of Available VLANs: 256IGMP multicast groups: 128 for each VLANPort rate limiting: User DefineJumbo frame Up to 9K BytesSecurity Features IP Police security featureEnable/disable ports, MAC based port securityPort based network access control (802.1x)VLAN (802.1Q ) to segregate and secure networktrafficRadius centralized password managementSNMPv3 encrypted authentication and accesssecurityRS-232 Serial RS-232 in DB9 connector with console cable.Console Port 115200bps, 8, N, 1LEDsFault contactPowerPowerconsumption(Typ.)Power Indicator (PWR)Green : Power indicator for AC and DCPower-1 Indicator (PW1)Green : Indicate Power-1 inputPower-2 Indicator (PW2)Green : Indicate Power-2 inputPower-3 Indicator (PW3)Green : Indicate Power-3 inputSystem Ready Indicator (STA)Green : Indicates that the system ready. The LED isblinking when the system is upgrading firmwareRing Master Indicator (R.M.)Green : Indicates that the system is operating inX-Ring Master modeX-Ring Indicator (Ring)Green : Indicates that the system operating in X-RingmodeGreen Blinking : Indicates that the Ring is broken.Fault Indicator (Fault)Amber : Indicate unexpected event occurredSysem Runnig Indicator (RUN)Green : System is operating continuouslySupervisor Login Indicator (RMT)Green : System is accessed remotelyReset To Default Running Indicator (DEF)Green : System resets to default configurationPing Command To The Switch Indicator (Ping)Green : System is processing “PING” request10/100/1000Base-T(X) RJ45 Port IndicatorLeft Green for 1000Mbps Link/Act indicator. Amberfor 10/100Mbps Link/Act indicatorRight Amber for full-duplex indicator100/1000Base-X SFP Port IndicatorGreen for port Link/Act.Relay output to carry capacity of 1A at 24VDC100~240VAC with power cord, dual 36 ~ 72VDCpower inputs at 6-pin terminal block33 WattsDatasheet Version 1.0www.lantechcom.tw | info@lantechcom.tw


Industrial Managed Switches3Overload current PresentprotectionOperating5% ~ 95% (Non-condensing)HumidityOperating-40°C~70°C / -40°F~158°FTemperatureStorage-40°C~85°C / -40°F~185°FTemperatureInstallation 19 inches rack mountableCase Dimension 431 (W) x 342 (D) x 44 (H) mmWeight4500 gEMI & EMS FCC Part 15, CISPR (EN55022) class AEN61000-4-2 (ESD)EN61000-4-3 (RS),EN61000-4-4 (EFT),EN61000-4-5 (Surge),EN61000-4-6 (CS),EN61000-4-8,EN61000-4-11Stability Testing IEC60068-2-32 (Free fall),IEC60068-2-27 (Shock),IEC60068-2-6 (Vibration)Warranty5 yearsMTBF415,000 hoursSoftware SpecificationIPv6Supported*NetworkRedundancyVLANIGMPQoSDHCPDOS/DDOS autopreventionIP-basedbandwidthmanagementPortconfiguration,status, statistics,monitoring,securityTOS/DiffservPro-Ring SystemSTPRSTPMSTPVLAN (802.1Q) with VLAN tagging and GVRPsupportedIGMP SnoopingQuality of Service (802.1p) for real-time trafficApplication-based QoS managementDHCP Client/ServerYesYesYesSupported*Optional FeatureORDERING INFOMATION• <strong>IGS</strong>-<strong>22416C</strong>……………………..P/N: 8370-65016 Gigabit Combo + 8 100/1000Base-X SFP Industrial Rack Mount Managed Ethernet SwitchWide Operating Temperature (-40°C to 70°C)OPTIONAL ACCESSORIESDIN Rail Power• AD1048-24FS• AD1024-24F• AD1240-48S• AD1120-48F24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°CMini GBIC (SFP)• 8330-162• 8330-163• 8330-165• 8340-0591• 8330-166• 8330-169• 8330-167• 8330-170• 8330-168• 8330-060• 8330-065MINI GBIC 1000SX (LC/0.5km) TransceiverMINI GBIC 1000SX2 (LC/2km) TransceiverMINI GBIC 1000LX (LC/10km) TransceiverMINI GBIC 1000LHX (LC/40km) TransceiverMINI GBIC 1000XD (LC/50km) TransceiverMINI GBIC 1000XD (LC/60km) TransceiverMINI GBIC 1000ZX (LC/80km) TransceiverMINI GBIC 1000EZX (120km) TransceiverMINI GBIC 10/100/1000T (100m) Transceiver100Base FX 2KM, Multi-mode, LC Transceiver100Base FX 5KM, Multi-mode, LC Transceiver• 8330-061 100Base LX 30KM, Single-mode, LC Transceiver• 8330-188 LTSFP-1000BX-10KM Transceiver (WDM 1310)• 8330-189 LTSFP-1000BX-10KM Transceiver (WDM 1550)• 8330-186 LTSFP-1000BX-20KM Transceiver (WDM 1310)• 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)• 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)• 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)• 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)• 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)• 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)• 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)<strong>Lantech</strong> <strong>Communications</strong> <strong>Global</strong> <strong>Inc</strong>.www.lantechcom.twinfo@lantechcom.tw© 2011 Copyright <strong>Lantech</strong> <strong>Communications</strong> <strong>Global</strong> <strong>Inc</strong>. all rights reserved.The revise authority rights of product specifications belong to <strong>Lantech</strong> <strong>Communications</strong> <strong>Global</strong> <strong>Inc</strong>.<strong>Lantech</strong> may make changes to specification and product descriptions at anytime, without notice.Datasheet Version 1.0www.lantechcom.tw | info@lantechcom.tw

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!