12.07.2015 Views

Product Guide 2012 - Lantech Communications Global Inc

Product Guide 2012 - Lantech Communications Global Inc

Product Guide 2012 - Lantech Communications Global Inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Lantech</strong> TM<strong>Lantech</strong> <strong>Communications</strong> <strong>Global</strong> <strong>Inc</strong>.Pioneering Industrial and IP NetworksContentAbout <strong>Lantech</strong>With a long background in IP Ethernet products, <strong>Lantech</strong> brings the bestnetwork solutions for Industrial and IP networks to the marketplace. The<strong>Lantech</strong> group is devoted to providing feature rich, high-quality networkingsolutions with outstanding service and support to our world-wide partners.<strong>Lantech</strong>’s core competency is centered around our network software andhardware, which allows for the seamless delivery of a variety of applicationsand services in diverse network environments.<strong>Lantech</strong> products are integrated with Pro-Ring, our proprietary auto networkrecovery protocol, and <strong>Lantech</strong>-View, Sever-Client utility for monitoring andconfiguring multiple switches at one time. <strong>Lantech</strong> is committed to providingour partners with the products, service and support necessary to help promoteour brand in the marketplace.<strong>Lantech</strong> offers a complete family of commercial and industrial grade networkingproducts in support of the global transition to all Ethernet services. <strong>Lantech</strong>products and solutions provide for the delivery of universal Ethernet servicesacross various markets and applications including:Rail Train SystemBuilding AutomationFactory AutomationPetroleum IndustryBus NetworkTunnel Traffic MonitoringWind Power MonitoringPower-SubstationOffshore PlatformCruise LinerWater Treatment PlantISP InfrastructureSurveillanceOthers<strong>Lantech</strong> products are distributed worldwide. We provide high quality productswith customer-centered services from our sales offices located in Taiwan,United States, Germany, and Korea. By combining our outstanding productsand services with knowledgeable and respected channel partners, <strong>Lantech</strong> isable to provide a significant price-performance value to any Industrial or IPnetwork.<strong>Lantech</strong> products are successfully transporting Ethernet services around theglobe, including networks at The Taiwan Post Office, In-store BroadcastingNetworks, Stanford University, CNN, Universität Würzburg (The University ofWurzburg), Korea U-city FTTX, Korea’s Subway System, Thailand’s SubwaySystem, Japan’s High-speed Railway, Israel’s wireless backhaul network andmany more.IndustrialSolutionsRail Train SystemBuilding AutomationFactory AutomationPetroleum IndustryBus NetworkTunnel Traffic MonitoringWind Power MonitoringPower-SubstationOffshore PlatformCruise LinerWater Treatment PlantISP InfrastructureTechnology<strong>Lantech</strong>-View Pro<strong>Lantech</strong>-ViewPro-Ring SystemPro-Ring II SystemUL C1D2 & DNVNetwork SecurityEN5015512345678910111213141517192123


Industrial EthernetSwitchesIndustrial EN50155 SwitchesIndustrial IEC 61850-3 SwitchesIndustrial DNV Type SwitchesIndustrial UL C1D2 SwitchesIndustrial Managed SwitchesIndustrial PoE SwitchesIndustrial Smart-Ring SwitchesIndustrial Entry SwitchesIndustrial Converters SeriesUniversal Redundant Fiber ControllerIndustrial Wireless Access PointIndustrial / Serial DevicesEthernet SwitchesCentral Managed Switches25272933374145464748495153PoE SeriesPoE seriesFiber ConvertersFiber ConvertersMini-GBICPower and AccessoriesPower and Accessories55575859


Rail Train SystemChallenges: The current conventional traincommunication networks (TCN) are facing severalchallenges to improve the service including thelimitation of bandwidth and integration. The devices inrailway systems often operate in a narrow and harshenvironment with unique requirements. For example,severe air pollution, vibration, shock and EMC arecommonly seen.Entertainment SystemDigital DisplayWireless ServiceTo interact with passengers fluently, theConnected with the control center, the digitalRail train provides Wi-Fi hotspot for passengersIndustrial Solutionsentertainment system requires Ethernetnetwork with high performances. Switcheswhich support IGMP protocol are able to satisfythe requirement with the multicast ability.display is able to show the news and passengerinformation immediately.to connect on the Internet, even during the highspeed moving status.Railway transportation has been becoming major trend for eco-friendlyand highly efficient transportation way, the major challenges aresecurity and control management. Train Communication Networksconsist of four elements- Security, Information, Control and Passengercommunications, in which every part is essential to make train cruisesafe and sound. Vibration, EMI/RFI, pollutants, input voltage ripple andsurge are the issues often found in the rail train network.<strong>Product</strong> SelectionsIPES-2208GF-67 (P.25)The EN50155 standard, which is “Railways Applications ElectronicEquipment Used on Rolling Stock”, is commonly adopted by manycountries and electronics manufacturers. Electronic equipment shall bedesigned and manufactured to meet the full performance specificationrequirement for the selected categories such as ambient temperature,shock and vibration, relative humidity, atmospheric pollutants,electrical service conditions, etc. <strong>Lantech</strong> provides a series of modelswhich is fully compliant with EN50155 standard.IPES-0008-4-M12 (P.25)IWP-2000-68 (P.49)P1


Factory AutomationChallenges: The most dynamic and challenging part forfactory automation floor network is redundancy andreal-time. Factory automation needs to be absolutelyaccurate because any interruption or delay could resultin huge amount of lost, especially when the operationis non-stop, 7/24/365. On the other hand, to satisfy therapid changing industry environment, manufacturingprocess must have high flexibility than before.Industrial SolutionsEthernetRS-485IES-2208CWeb ServerEmail,Trap EventsHuman Interface DeviceComputer WorkstationPro-Ring < 10msIES-2208CIES-2208CConveyor systemThe mechanical handling equipmentmoves materials from one location toanother, especially useful for theIDS-2102IDS-2102<strong>Lantech</strong>PLCRoboticArmRobotic ArmThe programmable robot manipulatoris designed to perform any desiredtask such as welding, gripping,transportation of heavy or bulkymaterials. It’s quick, efficient, andpopular in the material handling andpackaging industries.PLC<strong>Lantech</strong>IndustrialMotors/DrivesI/O DevicesRoboticArmspinning etc., depending on theapplication. The robot arm inautomotive assembly lines performs avariety of tasks with great accuracy.In factory automation applications, the most common structure consists of PLC, DCS, andSCADA. Based on IP protocol, managers are able to control equipments and transmit data toSCADA, where connects with database and then generate statistic data for monitoring theoperating status. <strong>Lantech</strong>’s Pro-Ring system provides the reliable Ethernet network amongthese devices and software with the fastest recovery time if failure. As the equipments are allutilizing IP protocol and connect to the Ethernet, it’s easier to integrate and changeconfiguration through Internet.<strong>Product</strong> SelectionsIES-2208C (P.37)Due to the requirement of absolute accurate data transmission, there is a huge need for realtime protocols in factory automation applications, including ProfiNet by Siemens, EthernetIP byRockwell, and ModBUS by Schneider. The real time protocols were developed by the need ofPLC’s connecting with robotic arms, conveyor belts and other automation devices for factoryautomation. This created the need for switches to be compatible with real time protocols. Bycollocating with Ethernet switches, managers are able to monitor the status, detect the failure,and solve the problem immediately.IDS-2102 (P.51)*All rights of brand names of Siemens, Rockwell, and Schneider mentioned herein belong to their respective holders.P3


<strong>Lantech</strong>Challenges: The whole petroleum industrial systemstarts from wellhead and ends with the refine system.Between wellhead and refine factory is the distributedsystem such as pump station and pipeline. Operatingenvironments of this industry are full of explode-ablematerials which may cause tremendous damages, nomatter at which part of production processes.Petroleum IndustryOil wellhead processAutomated oil tank monitoring system is one of themost important elements in oil wellhead process. ThisOil transmissionOil is transmitted via pipelines and pump stations. Inorder to ensure high and uniform flow of oil, pumpOil refining processIt is consist of several complicated and a large varietyof equipments/devices and need to be deployed byIndustrial Solutionssystem combines with data transferring, videostations are needed at regular intervals and pipelinesdistributed control system (DCS). DCS systems allowrecording, and voice, which requires huge bandwidth,must be under control. For example, to keep thethe entire system of controllers to be connected byreal-time reaction, and reliable durability.pressure in the pipeline at 50 bar pressure, managersnetworks for communication and monitoring.must monitor the status continuously.Human Interface DeviceComputer WorkstationIES-2307CULC1D2IES-2307CIPES-0005T-4IP Phone<strong>Product</strong> SelectionsIES-2307C (P.37)Pro-Ring


Bus NetworkChallenges: The primary applications for Bus Networkconsist of Surveillance, Smart Ticketing and Video onDemand. One of the key issues for BUS network is the24VDC or lower power input, which is not enough forstandard 802.3af PoE switches or standard Ethernetswitches. The other challenges like shock, vibrationand limited spaces are also needed to cope with.IWP-1000PoEUTPIndustrial SolutionsNVRIP CameraIPES-0008-4Digital Infomation DisplayIES-0216CTicket SystemLow voltagewhen engine startsIP cameraIt is one of the most importantNVRIt is a storage device collecting video<strong>Product</strong> SelectionsWhen bus starts engine from battery,it will draw a lot of current hence todevices and is able to record video24/7/365. PoE cameras normallyfiles and integrated with powerfulsurveillance software, manager willIES-0216C (P.46)make the voltage low and causeneed 48VDC power supply withget notice when any abnormal eventon-board devices not able to operate.switches that fully comply with thehappens through it.PoE standard to be fed power byEthernet cable.<strong>Lantech</strong> industrial switches are able to run with voltage as low as 9Vdc and offers the series ofPoE switch accepting 24V DC and boost to 48VDC for feeding power to surveillance system ofmoving vehicles. The 24V/48V DC <strong>Lantech</strong> PoE switch series are able to work in harshenvironment and provide up to 15.4w/port@48VDC to PDs. They are the best choice toconstruct a surveillance system for moving vehicles such as bus or railcar. Constructers don’thave to install an external booster, which may need extra cost and space.IPES-0008-4 (P.42)To meet with the critical network environment of a moving bus, the switch is protected by IP30housing and tested under extensive industrial EMI and safety standards. It also passed stabilitytests including free fall, shock and vibration. The wide operating temperature range of -40°C to75°C ensures the durability as well.IWP-1000b/g (P.49)<strong>Lantech</strong> PoE models comply with most of the leading PoE IP camera brands in the market, suchas AXIS, MOBOTIX, Sony, Panasonic, Samsung, NICE etc which ensures the stability whenconstruct an Ethernet network for the bus surveillance system.*All rights of brand names of AXIS, MOBOTIX, Sony, Panasonic, Samsung, NICE mentioned herein belong to their respective holders.P5


Challenges: Undoubtedly, the operating environmentof tunnel is harsh coping with humid with extremetemperature and pollutants in a tunnel generating bycars and other moving vehicles, the vibration caused bymoving vehicles is another challenge for networkdevices. Thus, a reliable Ethernet network is the toppriority for tunnel traffic monitor application.Tunnel Traffic MonitoringIP phoneIP phone is installed betweenselected intervals and is a vitaltool when there’s an emergencyin a tunnel.Ventilation fanDue to the pollutant and heatcaused during driving, the tunnelmust have these fans to maintainthe air circulation.Variable message signIt shows immediate traffic status,speed restriction, or weatherforecast. The message iscontrolled by control centerremotely via Ethernet network.To Upper Layer Switches via Dual HomingIndustrial SolutionsHEEDYOURSPEED! O O XTunnel ATunnel BPro-Ring Group 1O O X!HEEDYOURSPEEDPro-Ring Group 2,3IP PhoneTraffic SignFanControllerVMSIP Cam<strong>Product</strong> Selections<strong>Lantech</strong> industrial switches are able to sustain in tunnel projects by providing our high-qualityindustrial switches with redundancy of network recovery scheme. The Ethernet-based networkconnects IP CCTV, audio PA, telephones, VMS (Variable Message Signs), lighting control andventilation fans (SCADA system) and also some traffic control systems for management remotely.IES-2208F (P.37)<strong>Lantech</strong> managed switch support full management functions, including the IGMP protocol formulticasting, which is important for video transmission. To against the harsh environment,<strong>Lantech</strong> models operate well in the range from -40°C to 75°C and also pass several stability andsafety test including vibration, free fall, shock, EMI and EMC, to meet the difficult tunnelenvironment.IPES-2208C (P.42)<strong>Lantech</strong> products help to construct a highly reliable network connection by Pro-Ring system,which is the most important factor for an efficient traffic monitoring system, under the harshenvironment in tunnel.P6


Wind Power MonitoringChallenges: Long distance transmission between windturbines with stable and no data loss is one of themajor requirements in a wind power park. Doingmaintenance without interrupting network connectionis not easy, on the other hand. Harsh environmentrequires hardened network devices to overcome widetemperature range and strong vibration caused bywind as well as electrical interference.Industrial SolutionsWind turbine towerThe control box, which is at the top ofeach wind turbine tower, comprises aPLC, power inverter, control board, andI/O device. There’re sensors which collectwind speed, wind direction, shaft rotationspeed, and numerous other factors andthen transfer data to the PLC.Email,Trap EventsWeb ServerHuman Interface DeviceComputer WorkstationPro-Ring < 10ms<strong>Lantech</strong> provides a complete Ethernet solution with IES-2307C, the managed industrial switch,and IFR-0202, the universal redundant fiber controllers. The wind turbines are connected witheach other via optical fibers, providing the long distance transmission with stable quality.Several wind turbine towers are connected in a ring topology, where <strong>Lantech</strong> Pro-ring systemprovides the fastest redundant protection to prevent network interruption. Integrated withunique universal redundant fiber controllers, the fiber ring will be more reliable when facingmultiple switches’ power off. As for maintenance, it will be able to maintain one switch andkeep the connection active.All <strong>Lantech</strong> industrial products are passed several tests such as shock, vibration and free fall andmeet industrial EMI and EMC standards. The IP30 case and industrial grade components help toovercome the harsh operating environment in the wind power park.<strong>Product</strong> SelectionsIES-2307C (P.37)IFR-0202 (P.48)P7


Challenges: The Ethernet network is one of the mostsignificant infrastructure components used toconstruct the smart grid and the quality of network isthe key factor that affects the operating performance.The switches must overcome the harsh environmentwith strong EMI and support the real time protocol forseamless data transmission.Power-SubstationIEDVia an Ethernet network, theIntelligent Electronic Devices (IEDs)are able to connect with a RTU andsatisfy all management needs.RTUThe Remote Terminal Unit (RTU)collects and sends data to a centralcontrol room, which may be located along way from the substations whichmake up the Transmission /Distribution system.Industrial SolutionsIP CameraRTUIES-2224-2PHuman Interface DeviceComputer WorkstationIP PhoneIES-2224-2PPro-Ring


Offshore PlatformChallenges: The challenges of offshore platformnetwork application include coping with harshenvironmental conditions that has extreme operatingtemperatures, heavy moisture, erosion, extensiveshock and vibration. Also, extensive EMI can preventsome of the equipment used in the ship, especially thecompass and navigation systems, from operatingimproperly.Industrial SolutionsDNV ( Det Norske Veritas)The DNV Organizationoriginated in Norway. Initially,DNV was to provideconsulting services formanaging the risk and qualitycontrol systems onboard ships.Today, DNV Maritime isrecognized by 80 nationalmaritime authorities inmanaging their risk for the“Tough” maritime environmentalconditions.Bypass hydrauliccontrol systemNormally, an offshoreplatform equips with oneor several cranes to liftcargo around theplatform and betweenboats. This controlsystem helps adjust thecranes.Crane heave motioncompensatorLocated near the bypass hydrauliccontrol system, the compensator isfor keeping the load at a fixedposition relative to the seabed, and toavoid that the vessel motion is beingtransferred to the load. The AHCcontrol is connected to a motionreference unit (MRU) that feeds thesystem with accurate real-timeinformation of the crane tip motion.Helicopter landing padCommonly abbreviated as helipad,which is the landing area forhelicopters. For offshore platform,helipad also referred to as helideck.<strong>Product</strong> SelectionsIES-0204FT-DNV (P.29)IES-0008T-DNV (P.29)Problems caused by erosion, heavy moisture and extreme working temperatures are commonlyseen on offshore platforms. <strong>Lantech</strong>’s DNV (Det Norske Veritas) type industrial switches aredesigned to cope with this kind of harsh environment. Given the diversity of locations thatswitches may be used, Industrial Switches are needed for the various types of approvals underDNV classification.DNV maritime certification specifics the test criteria for all equipment used for offshoreplatforms. Most of the <strong>Lantech</strong> DNV models are UL class I division II certified, which ensures thesafety when installed at the flammable places.LGS-2816C-RPS-DNV (P.30)P9


Cruise LinerChallenges: Marine ships are confronted with severalchallenges for on-board equipment including vibration,high voltage, conducted radio frequency immunity andemission. For the adventure of on-board passengers,entertainment system is featured by cruise liners, so areliable and high efficient Ethernet network is essentialto handle all video, voice and data packets fromeverywhere in the ship.Sonar systemThe sonar system, which helps to locatethe position, requires a high-speednetwork to connect devices in the hullunit room with other devices on thebridge.Entertainment systemTo offer best comfort and luxury joy forpassengers on-board, cruise liner hasamenity of room-entertainment systemswhere can choose movie, music or otherentertainment programs they want atanytime.Control RoomUTPFiberDHCPServerDHCPServerLES-2400-RPSIEC-0101FT-DNVPro-RingPro-RingPro-RingIES-2208F-DNVDeck AIES-2216C-DNVDeck BDeck CDeck surveillancesystemSince the cruise linercarries a lot ofpassengers, it isimportant to monitoreveryone’s safety. Thesurveillance system ateach deck is connected tothe central control room.Industrial SolutionsFor sonar system, the Ethernet network allows the transmission of signalsfrom the sonar to the ship’s bridge in real time. <strong>Lantech</strong> provides a totalsolution, combining our industrial grade and business grade models tomaximize the benefit. Both industrial grade and business grade modelspassed the extreme tests of DNV, providing the qualified protection forthe cruise liner. For example, extensive EMI can prevent some of theequipment used in the ship, especially the compass and navigationsystems, from operating improperly.IEC-0101FT-DNV (P.29)<strong>Product</strong> SelectionsLGS-2816C-RPS-DNV (P.30)Industrial switches can be used in the hull unit room to connect todifferent sonar devices, while the aggregated switches are installed in thebridge. Together, the switches create a redundant ring that connects theend devices to the control center. On the other hand, the fiber opticalconnection ensures the smooth and seamless video transmission forsurveillance system at each deck with its huge bandwidth.IES-2208F-DNV (P.30)IES-2216C-DNV (P.30)P10


Water Treatment PlantChallenges: Water treatment process is essential formodern life to make water more acceptable andeliminating bad residues existing in many publicsanitation systems then to return water back intonatural environment without ecological impacts for theuse of drinking water, industrial process, medical, hotelprocess and others.Industrial SolutionsUpper Layer SwitchSedimentation tankIt is the final step in the secondary treatment stage, which is the mostrepresentational structure of a water treatment plant. Through aRTURTUsecondary clarifier, the biological floc or filter material is settled out. Afterthis step, sewage water containing low levels of organic material andRagular Ethernet Pathsuspended matter is produced.X-Ring Backup PathDual Homing Backup PathRTUIP CameraRTUIP Phone<strong>Product</strong> SelectionsUsing the industrial Ethernet network is the most convenient and reliable solution for watertreatment system to connect with SCADA, PLC, water sensors, water bumps etc. Since thewater treatment plant might cover huge floor space, the long transmission distance becomesone of the major considerations.IES-1005T (P.33)By utilizing <strong>Lantech</strong>’s Pro-Ring system, the connection quality is protected under this fastredundant ring protocol, which is less than 10ms. Subject to different areas connection such asdrainage well and leveraged wells, the switches could connect with aerator RTU, sludge removalRTU, or primary clarifier RTU, etc and protect all by Pro-Ring scheme. Via <strong>Lantech</strong> products, thewhole network system is able to be monitored from control room remotely.IES-1204FT (P.45)P11


Challenges: Due to extremely connection demand, theISP infrastructure requires absolutely high densitynetwork capacity. To transmit data efficiently, thereshould be a useful and universal network protocol. Tomanage the large amount of users is another issue,which is very important for customer satisfaction.ISP InfrastructureISPPro Ring < 10msEnd UsersTriple PlayIt is a marketing term for theprovisioning of twobandwidth-intensive services,high-speed Internet accessand television, and a lessbandwidth-demandingservice, telephone, over asingle broadband connection.Although voice servicerequires less bandwidth, it ismore latency-sensitive due toreal time communications.Industrial SolutionsFiberRJ45FiberNode<strong>Product</strong> SelectionsWith <strong>Lantech</strong>’s high density fiber gigabit or 100M aggregation switches, it is easy to build up abackbone network for ISP demand. The bandwidth-intensive services such as internet accessand video can be transmitted fluently. Fiber connection allows long distance data transmissionup to 120km, making remote management more easily.IGS-2404-E (P.34)IGMP, which is a universal network protocol, helps to reduce network traffic and provides goodnetwork quality for triple play usage. The power input range is another issue when installing ISPinfrastructure since most of the power supply is restricted to 48VDC in ISP infrastructureenvironment. To solve the problem, <strong>Lantech</strong> industrial switches provide wide range redundantpower inputs, which make <strong>Lantech</strong> products the best choice for ISP applications.IGS-2206C (P.34)P12


<strong>Lantech</strong>-View Pro<strong>Lantech</strong>-View Pro is a server-client architecture network management software and can automaticallydiscover <strong>Lantech</strong> Industrial Switches to be shown in the network topology drawing. <strong>Lantech</strong>-View Proprovides a powerful management platform for <strong>Lantech</strong> Industrial Switches by offering statistic, monitoring,configuration for real-time network management.• Network topology view • Device discovery • Network statistic• Device Fault alarm • Device Web Interface • Batch firmware upgrade• Batch IP assignment • Device management • Telnet via NMS• MIB browser • MIB Complier • Polling Node• Event Count • Editable tool bar • Threshold Event Monitor• Throughput Monitor • Trap View Monitor<strong>Lantech</strong>-View Pro▲Ordering InformationLVPro_50 <strong>Lantech</strong> View Pro 50 nodes ; server version + USB keyLVPro_100 <strong>Lantech</strong> View Pro 100 nodes ; server version + USB keyLVPro_250 <strong>Lantech</strong> View Pro 250 nodes ; server version + USB keyLVPro_500 <strong>Lantech</strong> View Pro 500 nodes ; server version + USB keyLV_Unlimited Unlimited nodes ; sever version + USB keySupport FunctionNetwork topology viewDevice discoveryNetwork statisticDevice Fault alarmDevice Web InterfaceBatch firmware upgradeBatch IP assignmentDevice managementTelnet via NMSMIB browserMIB ComplierPolling NodeEvent CountEditable tool barThreshold Event MonitorThroughput MonitorTrap View MonitorSupport ModelAll Industrial ManagedSwitches except IES-2206F-IIP13


<strong>Lantech</strong>-View<strong>Lantech</strong> View is the Windows-base powerful network management utility. With its friendly and powerfulinterface, you can easily configure multiple <strong>Lantech</strong> Industrial switches at the same time, and monitorswitches’ status.<strong>Lantech</strong> View is a smart tool, which can auto discovery devices connected to a network. With its powerfulfunctions for switch configuration, our customers can configure multiple switches concurrently. It canmonitor multiple switches status easily, providing a more convenient management solution. As a useful toolto maintain switches firmware and configuration, <strong>Lantech</strong> View is able to upgrade batch firmware andbackup configure file for multiple switches at one time.▲Ordering InformationLV_50<strong>Lantech</strong> View Utility 50 nodes ; Window version + USB keyLV_100<strong>Lantech</strong> View Utility 100 nodes ; Window version + USB keyLV_300<strong>Lantech</strong> View Utility 300 nodes ; Window version + USB keyLV_500<strong>Lantech</strong> View Utility 500 nodes ; Window version + USB keyLV_Unlimited Unlimited nodes ; Windows version + USB keySupport List : IES-1005T, IES-1204FT, IES-1005-67, IES-2206F-II( Windows Utility / Free-bundle version is for 10 nodes )▲Auto discovery device<strong>Lantech</strong>-View▲Topology View providesan auto-topology-drawing function*.▲Multiple switches setting function▲The live status monitor function willdetect connection status automatically*.*Please notice that these functions only works for LLDP(Link Layer Discovery Protocol) supported switches.▲Device status monitoring▲Device Information▲Warning: device is abnormal▲TFTP Backup▲Link DialogP14


Pro-Ring SystemFor Ethernet, network redundancy means a network hardware link down or disconnection cable will notinterrupt communications. Also, to achieve network redundancy, one must use a managed switch, sinceadvanced traffic management is required to prevent "looping" of data packets.Where an interruption of a few seconds is acceptable in the office, it’s an eternity for most manufacturingenvironments or other mission-critical networks. A communication gap of a few seconds or more couldcause loss of critical data or worse yet -- system shutdown.Common enterprise technologies like Rapid Spanning Tree Protocol (RSTP) generally take between 2 to 10seconds to recover after a fault, and older technologies like Spanning Tree Protocol (STP) could take evenlonger -- 30 to 60 seconds.Pro-Ring SystemPro-Ring system is a proprietary protocol, for applications where a ring architecture is desired (mostmanufacturing or other mission-critical projects) that uses a pulling scheme to detect whenever a cablebreak or link fault occurs, it will automatically find a backup path in under 10 milliseconds for networks of upto 250 <strong>Lantech</strong> switches.As a result, Pro-Ring system is very important in applications where downtime is expensive.<strong>Lantech</strong> new Pro-Ring II system eliminates the need to manually set ring master and evolves comprehensiveredundant ring architectures.X-Ring ApplicationBasic Pro-Ring system is X-Ring.Data collect serverEnterprise SwitchHuman Management InterfacePro-RingBackup pathPro-RingR.T. < 10msField ManagementIndustrial SwitchIndustrial SwitchDistribute I/O control systemProgrammable logic controllerField Automatic deviceSerial Device ServerField Automatic deviceP15


Coupling Ring ApplicationCouple Ring is designed for the Network redundancy between two Rings.Coupling PortCoupling RingBackup PathCoupling PortBackup pathSwitch 1Control PortCoupling RingGroupControl PortSwitch 3Pro-Ring Group AR.T. < 10msSwitch 2Coupling PortSwitch 4Pro-Ring Group BR.T. < 10msBackup PathBlockingPortDual RingBackup pathCentral / Dual Ring ApplicationCentral Ring can ring together 4 ring in which one managed switch could be the ring master, while Dual Ring isstructed within two rings by one ring master.Pro-Ring SystemRing 3R.T. < 10msRing 1R.T. < 10msRing 2R.T. < 10msRingMasterRing 4R.T. < 10msForwardingPortDual Homing ApplicationDual Homing is to have back up path when the ring is connected to upper switch that is from third-party by RSTPalgorithem to be recoverd in 5 seconds.Enterprise SwitchRapid Spanning Tree ProtocolEnterprise SwitchHot Standby LinkPro-RingBackup pathIndustrailSwitchPrimary Dual-HommingPro-Ring Group AR.T. < 10msDual HommingBackup portPrimary Dual-HommingPro-Ring Group BR.T. < 10msIndustrailSwitchSecondary Dual-HommingPro-RingBackup pathRing MastersRing MastersP16


Pro-Ring II SystemPro-Ring II is a new Ring mechanism for <strong>Lantech</strong> Industrial Switches in which it eliminates the need to pre-setthe Master switch in old Pro-Ring and yet to protect the network by much secure topologies than ever.Pro-Ring II works as a Ring Chain to reduce the risk of master switch linking down whereas the setupbecomes much easier. Pro-Ring II can be backward compatible with old Pro-Ring by down-grading the Ringscheme to old one.Daisy-Couple RingFor larger and single LAN group, Daisy-Couple Ring could achieve self-recovery time in less than 10ms inwhich the ring group will choose automatically for Master switch, detect loop and form path recoveryarchitecture.Backup Path Backup Path Backup PathPro-Ring II SystemBackup Path Backup Path Backup Path Backup PathPro-Ring II Pro-Ring II Pro-Ring II Pro-Ring IIMulti-Couple RingFor multiple ring groups, it helps to structure ring activities among different LANs. Each ring group has morethan 3 redundant paths for backup.Backup PathPro-Ring IIBackup PathBackup PathBackup PathBackup PathBackup Path Backup Path Backup Path Backup PathPro-Ring II Pro-Ring II Pro-Ring II Pro-Ring IIBackup Path Backup Path Backup PathAdvanced Dual HomingWhen the ring group is connected to upper switch by RSTP algorithm, it strengths the uplink connectionwith its own redundant path which double secures the link than of traditional Dual Homing.RSTPBackup PathBackup PathBackup PathBackup PathBackup PathBackup PathBackup PathPro-Ring IIPro-Ring IIP17


Key Ringfuture releaseWhen the middle or aggregation points are critical, Key Ring can protect the middle connectionto the core or upper switch by separating different layers of links or ring groups.Backup PathPro-Ring IIKey-RingBackup PathPro-Ring IIBackup PathPro-Ring IIMulti-Key RingMulti-Key Ring forms triangle connection among different ring groups to create the de-militarizedzone in the network topology and maintain the redundancy.Backup Pathfuture releasePro-Ring IIBackup PathPro-Ring IIBackup PathPro-Ring II SystemBackup PathBackup PathBackup PathPro-Ring IIBackup PathPro-Ring IIBackup PathBackup PathBackup PathPro-Ring IIBackup PathBackup PathFeatures Pro-Ring II Pro-RingRedundancy Solution ★15 3Auto Master Selection ★Yes NoMax. unit 250 250Single algorithm ★Yes NoRecovery time for Dual-Homing ★


UL C1D2 & DNVTypical Oil, Gas & Mining applications that require UL Class I Division II certification:UL C1D2 & DNVNowadays Industrial Ethernet switches and Industrial Ethernet based devices aremore suitable for their environments and applications; they are designed to meetthe riggers of the task at hand which in some cases includes a harsh environmentlike Oil, Gas and Mining industry.Some of the facilities that would utilize equipment that would fall into thisapplication environment would be Oil Refineries, Oil Platforms andPetro-Chemical Plants these types of facilities would have a need to installIndustrial Ethernet based switches and devices for process control andmonitoring. These types of facilities require devices that are certified to meet theharsh environments they produce.For example, in the Petro-Chemical industry, controlling and monitoring siteconditions and dynamic changes in those conditions are mission critical. Thedevices and more importantly the network which is made up of Ethernetswitches, Media Convertors, Routers, Gateways and Fiber Optic cables arecombined to allow these devices to communicate these changes; the combined devices and componentsmust be of a mission critical nature as well and it must be able to withstand the rigorous challenges of itssurroundings. Thus the need and the absolute promise of the “UL Class I Division II” certification of thenetwork equipment or the Industrial Ethernet based switches and devices. At this level of severity, the riskfor loss of life and property is at its highest and this certified equipment provides reliable, secure and rapiddata transmission, so that the administrators controlling and monitoring the plant’s activities can detect anyabnormal situations quickly enough for them to take the necessary actions to prevent an accident or adisaster.In order to overcome these hazardous environments, the relative device should pass a variety of testing andcertification. These devices face some pretty tough conditions. While striving to maintain high safetystandards and efficient operating costs, companies demand rugged protection for the critical equipmentthat controls power generation and distribution. These test and certifications including the extremetemperature, IP rating and three kinds of stability test (free-fall, vibration, shock), with a certain degree ofresistance to shock, vibration-resistant properties that ensure the normal functionality under harshenvironments. With “UL Class I Division II” approval, Ethernet switch and devices can be deployed inhazardous or explosive condition without increasing the risk of explosion or acceleratingthe damage if an accident occurs.UL Class I Division II & DNVSeveral harsh environment certifications have been established by third party testingagencies, one such certification is “UL Class I Division II” this is one of the most widely usedby the most trusted names of the testing agencies. Underwriters Laboratories (UL) is oneof the testing agencies that certifies these types of systems as safe for use in the highestlevel of hazardous locations; these types of locations would include but not be limited topotentially explosive location or location where all electronic circuits and / or devices mustbe intrinsically safe. An Intrinsically Safe Circuit is "A circuit in which any spark or thermal effect is incapableof causing ignition of a mixture of flammable or combustible material in air under prescribed testconditions." (See UL 913)P19DNV Certification for Maritime Oil & GasAnother such testing agency similar to UL is DNV (Det Norske Veritas), DNV is a classification societyorganized as a foundation, with the objective of "Safeguarding life, property, and the maritimeenvironment". DNV’s approval process entails verification of a set of requirements and processes; theserequirements and processes encompass the design, construction, and operation of devices used on-boardships and offshore units. DNV has four levels-A, B, C, and D of classification of their tests. These would rangefrom the most basic to the most critical and separate tests are conducted for other types of conditions(temperature, humidity, vibration, etc.). The use of Ethernet based devices combined with a fiber optic backbone make it much easier for the control center to coordinate and control data from many different systemsover a common communication platform. Any such network in use aboard a offshore platform or maritimevessel, would be subject to have passed the DNV’s strict testing procedures and processes; this wouldinclude all the Ethernet based devices proving the worthiness in the Maritime Oil & Gas Industry. Being oneof the world's leading classification societies, DNV’s certification are recognized globally as an indication thata product is fit for use in the well-defined classes of marine environments and applications.


Typical DNV Applications:Ethernet devices can be used to solve communications problems for a number of marine applications. Theutilization of Ethernet network aboard maritime vessels will benefit all types of vessels from battleships andocean liners; which when fully manned could be home to several thousand soldiers or passengers. Energyrelated applications, such as offshore drilling platforms, tide-power generation systems, and offshorewindmill farms, could also benefit from using Ethernet.For example, offshore platforms are common DNV application. Generally, it is necessary to set up asophisticated automated monitoring system to ensure that all systems work properly. The deployment ofan IP network for the monitoring and control system makes it easier to establish a platform-wide systemthat connects all the monitoring and controls systems onto one common network platform. All thecommunication and monitoring devices used on an offshore platform including the Industrial Ethernetbased switches and devices must be capable of withstanding critical ocean environments, including theeffects of moisture, vibration, shock, and temperature extremes.<strong>Product</strong> Design for UL Class I Division II &DNVEthernet switches and devices that pass “UL Class I Division II” testing or the requirements’ of the DNVneed to be able to withstand inclement weather, environmental and equipment generated temperatures,shock and vibrations, dust and dust particulates. Here are some of the details with regards to theabove mentioned requirements for certification; all these devices must be designed to demonstrate to thetesting agencies that they meet or exceed these requirements while maintaining an optimal operatingstandard: These requirements include but are not limited to intrinsically safe operations, extreme storagetemperatures, Wide operating temperature ranging from -40°C to 75°C, Vibration and shock tests (free fall,mounting surface vibrations, etc.), IP-54 or IP-67 grade for absolute-protection for dust-proof and water-resistant enclosures.SummaryAs mentioned in the previous section, UL “Class I Division II” safety certification makes that switch or devicewith this certification your best choice for intrinsically safe operating areas or environments.DNV certification will ensure that the switches and devices have met the requirements’ of design,constructions and rigorous testing to be certified for maritime use in all maritime vessels or offshoreplatforms.UL C1D2 & DNVUL C1D2 <strong>Product</strong> List:IES-0005T IES-0008T IEC-0101FTIGS-2206C IGS-2404-E IES-2208FIGS-0008T IGC-0101GB IPES-0008-4 IES-2307CIES-2216CDNV <strong>Product</strong> List:IES-0005T-DNVIES-0008T-DNVIES-0104FT-DNV*IES-2208F-DNV*IES-2008A-DNV*IES-2216C-DNVIES-0204FT-DNV*IEC-0101FT-DNVIES-1204FT-DNV*IGS-2404-E-DNV*LGS-2816C-RPS-DNV*LGS-2624C-DNV**DNV Type Approval is pendingP20


Network Security: SSH / SSLHow IP security function benefit Ethernet network security?Network security for switches and network infrastructure is gaining more attention than it once did asmore people and businesses rely on their networks as a normal course of their daily lives and businesses.Most people who have direct oversight of their network security are concerned about the safety andsecurity of their network, especially as it relates to data exchanges between offices, cites, states andcountries. With the critical nature of networks to keep businesses moving forward and the amount ofmission critical data that is pushed and pulled across these networks, the more vulnerable these systemsappear to be. The looming doom of a security threat or infrastructure failure can have cascading affects onany business that relies heavily on their network to conduct their daily operations and the threat is not assimple as trying to achieve the task of keeping the bad guys out, this threat is a multi-headed monster orHydra.Network SecurityThe Hydra’s perceived strength came from a multiple head attack and it defense was the re-growth of twoheads for every one head that was lost; the Hydra’s attack and defense is very similar to today’s securitythreats meaning you find a way to stop one and then two more pop up in its place. One of the heads /threats being man made (Viruses and Hackers) , another head / threat is self inflected issues (receiving aninfected email or using an unauthorized device such as a USB Drive) and yet another head / threat comesfrom several single points of hardware failure that can cause cascading down line failures.Man-made security threats are the most difficult ones to try and control and the difficulty comes from thefact that most of these threats are unleashed by innocent users of the system; an email, a random CD or aUSB memory stick. These users are not master mind computer hackers, most of the time they are unawareof their simple acts of just receiving an email that contains a network crippling virus. This is the challengethat IT directors across the world have to try and be prepared for, part of this preparation is to bepro-active in their attempts to try and limit their networks exposure to these threats and they do this withhardware, software and strict policies but as we all know the best laid plans of mice and men are notalways enough. This article will address how hardware and technology developers are making great stridestowards providing a solution to protect networks from all the threats that exist today.IP security (SSH、SSL)IP security is an end-to-end security scheme operating in the Internet Layer of the Internet Protocol Suite. Itcan be used in protecting data flows between a pair of hosts ( host-to-host ), between a pair of securitygateways (network-to-network), or between a security gateway and a host (network-to-host).Some other internet security system, such as SSH and SSL are common widespread use in network.User can use SSH to prevent unauthorized access to critical devices. SSH is a network protocol that allowsdata to be exchanged using a secure encryption between two networked devices. SSH uses public/privatekey RSA authentication to check the identity of communicating peer machines, and provides dataencryption using algorithms. SSL is a protocol that uses a cryptographic system that uses two keys toencrypt data − a public key known to everyone and a private or secret key known only to the recipientof the message.802.1x/RADIUSSecurity ToolNAC Address TableP21


Mac filteringMac filtering is another security access control method in computer networking. MAC addresses areuniquely assigned to each card, so using MAC filtering on a network permits and denies networkaccess to specific devices through the use of blacklists and white lists. While the restriction of networkaccess through the use of lists is straightforward, an individual person is not identified by a MAC address,rather a device only, so an authorized person will need to have a white list entry for each device that he orshe would use to access the network.802.1x RADIUS802.1x makes use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide ameans of authenticating and authorizing devices attached to a LAN port that has point-to-point connectioncharacteristics, and of preventing access to that port in cases in which the authentication and authorizationprocess fails. Besides firmware system, hardware security protecting also has some functions to protectnetworks for users. Some infrastructures in harsh environment need solid equipments to against theexternal environment destruction, such as railway network.The Switches apply to railway network should design more firmly. Because all the devices are connectedwith Ethernet, it is easier to integrate new systems and new applications. The ability of high-bandwidth isanother theme for discussion. Ethernet backbones are able to provide a reliable network environment forimplement of applications such as passenger entertainment systems and high-quality video s urveillanceapplications. Connected with Ethernet cables, the installation and maintenance is much easier with lesscost. In order to create the full fine performance, the railway network security would count on well-designswitches to meet with critical network environment.EN50155 series switches may trusty for Ethernet infrastructures. The consideration point of security to useEN50155 series switch might come from the following sources.Network SecuritySSH / SSL <strong>Product</strong> List:LGS-2816C-RPSLGS-2624CLPGS-2624C IES-2008-67 IPES-2008-67IPES-2208GF-67IES-2307C IPES-2208C IGS-2404-E IDS-2101F IDS-2102 IDS-2204P22


EN50155EN50155 series switchDifferent to the comfortable environment for passengers, the Ethernet devices in railway applicationsoften operate in a narrow and harsh environment with unique requirements. Devices in rail train must beable to suffer under wide range temperature and humidity. Furthermore, severe air pollution, vibration,shock and EMC are commonly seen. That’s why Industrial Switches are needed to be certified byEN50155 standard.The EN50155 standard is “ Railways Applications Electronic Equipment Used on Rolling Stock ”, which iscommonly adopted by many countries and electronics manufacturers. Electronic equipment shall bedesigned and manufactured to meet the full performance specification requirement for the selectedcategories such as:EN50155> Ambient temperatureAccording to diverse severe environments, there are four grades of operating temperaturerequirements defined by the EN50155 standard and are stated in the following table:ClassAmbienttemperatureoutside vehicleInternalcabinettemperatureInternal cubicleover -temperatureduring 10 minAir temperaturesurrounding the printedboard assemblyT1 -25°C to 40°C -25°C to 55°C 70°C -25°C to 70°CT2 -40°C to 35°C -40°C to 55°C 70°C -40°C to 70°CT3 -25°C to 45°C -25°C to 70°C 85°C -25°C to 85°CTX -40°C to 50°C -40°C to 70°C 85°C -40°C to 85°C> Shock and vibrationEN50155 adopts testing methods and limitation according to EN 61373 - Railway applications - Rollingstock equipment - Shock and vibration tests. The standard ensures the equipment to be able towithstand vibrations and shocks and provides the specified useful life under service conditions. Tosatisfy the requirements, the equipment should be specifically designed with anti-vibration mounts andinstalled the electronic units completely.> Relative humidityEN50155 defines the relative humidity standard that equipment should follow: The equipment shouldbe able to withstand 75 % of the average yearly relative humidity and 30 consecutive days with 95 %relative humidity in the year. IP67 enclosure is one of the best solutions, which provides rugged andwaterproof protection to against moisture environments that may cause any malfunction or failure.> Atmospheric pollutantsThe equipment may be exposed in different locations where various pollutants are available,including oil mist, salt spray, conductive dust, Sulphur dioxide. To ensure the durability, theequipment should have IP-rated enclosure to against the negative effects from these pollutants.P23


Electrical service conditionsTo overcome the severity and provide the stable services in railway applications, EN50155 also definesseveral standards for electrical service conditions such as input voltage range, input voltage ripple, andinput surges. Each category follows clear requirement. For example, the requirements of input voltage arelisted below:Input Voltage RequirementsNominal Input Permanent inputvoltage rangeBrownout 100ms(0.6xVnom)Transient 1s(1.4xVnom)24VDC 16.8 -30.0V 14.4V 33.6V37.5VDC 26.2 -47.0V 22.5V 52.5V48VDC 33.6 -60.0V 28.8V 67.2V72VDC 50.4 -90.0V 43.2V 100.8V96VDC 67.2 -120.0V 57.6V 134.4V110VDC 77.0 -137.5V 66.0V 154.0VElectromagnetic compatibility (EMC) is another main category of EN50155 standard. The equipment shouldbe protected in order not to be negatively affected by conducted or radiated interference, which is referredto EN 50121-3-2 and should not emit radio frequency interference (RFI) that excess the level defined inEN 50121-3-2.EN50155EN50155 series models provide IP-67 protection and M12 connectors with wide operating temperaturefrom -40°C to 75°C for harsh operating environment in railway applications. The rugged and durableswitches have long MTBF that ensure the network quality of video entertainment service and high qualityvideo surveillance at the same time with Giga fiber ports. Besides hardware specifications, the powerfulsoftware features also ensure the management convenience. A well-design switches security functions areessential to securing modern Ethernet network.EN50155 <strong>Product</strong> List:IES-0005-M12 IES-0008-M12 IPES-0008-4-M12 IES-2008-67 IPES-2208GF-67 IPES-2208-M12P24


Industrial EN50155 SwitchesDesigned for railway and other rugged applications,<strong>Lantech</strong> EN50155 compliant series provides from IP41to IP67 rated protection against dust and water jet orimmersion. The M12 connectors ensure reliableoperation with on-board devices. The series alsosupports fully managemant functions with high levelsecurity and <strong>Lantech</strong> Pro-Ring redundant system.Industrial EN50155 SwitchesIES-0005-M125 10/100TX M12 /IP41 Industrial SwitchIES-2008-678 10/100TX M12 /IP67 Managed Industrial Switch-UL508IES-0008-M128 10/100TX M12 /IP41 Industrial SwitchIPES-2208GF-678 10/100TX + 2 1000FX M12 /IP67 Managed Industrial Switchw/8 PoE 802.3af Injectors-UL508 / UL C1D2IPES-0008-4-M128 10/100TX M12 /IP41 Industrial Switchw/4 PoE 802.3af Injectors-24~48VDC Power InputIPES-2208-M128 10/100TX + 2 10/100/ 1000TIP41/IP65 w/8 PoE 802.3af InjectorsIndustrial Managed SwitchIES-1005-675 10/100TX IP-67 Smart Industrial Ethernet Switch-Non EN50155128-bitEncryptionPro-Ring 50 mm 1 Dripping water2 > 12.5 mm 2 Dripping water when tilted up to 15°3 > 2.5 mm 3 Spraying water4 > 1 mm 4 Splashing water5 Dust protected 5 Water jets6 Dust tight 6 Powerful water jets7 Immersion up to 1m8 Immersion beyond 1mP25


HARDWARE FEATURESPortIES-0005-M12 IES-0008-M12 IPES-0008-4-M12 IES-1005-67 IES-2008-67 IES-2208F-6710/100TX 5 (M12) 8 (M12) 8 (M12) 5 8 (M12) 8 (M12)100FX - - - - - 2 (LC)1000FX - - - - - -1000M SFP - - - - - -10/100/1000T/Dual Speed SFP Combo - - - - - -RS232 connector M12 M12 M12 RJ45 M12 M12PoE Injector - - 4(802.3af) - - -Switching Fabric 1.0Gbps 1.6Gbps 1.6Gbps 1.0Gbps 5.6Gbps 5.6GbpsPacket Buffer 448Kbits 448Kbits 448Kbits - 1Mbits 1MbitsMac Address 2K 2K 2K 2K 8K 8KFlash ROM - - - - 4Mbytes 4MbytesDRAM - - - - 32Mbytes 32MbytesPower Supply*Optional9~56VDC(M12 connector)9~56VDC(M12 connector)24~48VDC(M12 connector)9~30VDC(M12 connector)9~56VDC(M12 connector)9~56VDC(M12 connector)Redundant Power ● ● ● ● ● ●Power Consumption 2.5 Watts 2.5 Watts 4.5 Watts 3 Watts 14 Watts 14 WattsOverload Current Protection ● ● ● ● ● ●Polarity Reverse Protection ● ● ● ● ● ●Relay Contact with Alarm System - - - - ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● ●Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ●Case DimensionW x D x H (unit=mm)92 x 180 x 42 92 x 180 x 42 92 x 180 x 42 90 x 40.5 x 155 193 x 62.5 x 176 193 x 62.5 x 176Case Protection IP41 IP41 IP41 IP67 IP67 IP67Weight 750g 800g 900g 470g 1630g 1630gDIN Rail Installation ● ● ● ● - -Wall Mount Installation ● ● ● ● ● ●CE/ FCC/ UL ● ● ● CE/FCC CE/ FCC/ UL508 ●RoHS/ WEEE ● ● ● ● ● ●EN50155/ e-Mark Pending Pending Pending - Pending PendingStability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● ●MTBF 391,306 hours 391,306 hours 348,384 hours 662,177 hours 388,201 hours 320,420 hoursWarranty 5 years 5 years 5 years 5 years 5 years 5 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 - - - ● ● ●Web Browser - - - ● ● ●Telnet - - - - ● ●CLI - - - - ● ●<strong>Lantech</strong> View /<strong>Lantech</strong>-View Pro - - - <strong>Lantech</strong> View <strong>Lantech</strong>-View Pro <strong>Lantech</strong>-View ProIGMP snooping v1 v2/ IGMP query - - - - ● ●VLAN - - - Port Based VLAN ● ●Port Trunk with LACP - - - - ● ●LLDP - - - - ● ●SSL/ SSH - - - - ● ●Port Security - - - ● ● ●IP Security - - - - ● ●Login Security (RADIUS) - - - - ● ●SNTP - - - ● ● ●SMTP - - - 6 e-mail accounts 6 e-mail accounts 6 e-mail accountsBandwidth Control - - - - ● ●Flow Control - - - - ● ●Pro-Ring SystemX-Ring - - - ● ● ●Dual Homing - - - - ● ●Couple Ring - - - - ● ●Central Ring - - - - - -Dual Ring - - - - - -Spanning Tree/ RSTP - - - ● ● ●Port Mirror - - - - ● ●Quality of Service - - - - ● ●Class of Service - - - - ● ●System Log - - - - ● ●Relay Alarm - - - - ● ●SNMP Trap - - - - ● ●DHCP - - - - Client/ Server Client/ ServerDNS Client/ Server - - - - ● ●TFTP Firmware Update/ Backup /Resotre - - - ● ● ●Configuration upload and download - - - - ● ●ORDERING INFORMATION (part number)Wide Operating Temp. (-40°C~75°C)IES-0005-M12 IES-0008-M12 IPES-0008-4-M12 IES-1005-67 IES-2008-67 IES-2208F-678360-480 (MM, 2KM)8360-556 8360-550 8360-540 8350-1918 8360-4908360-481 (SM, 30KM)P26


Industrial IEC 61850-3 Switches<strong>Lantech</strong> IEC 61850-3 series features high reliability androbustness. Each model is compliant with IEC 61850-3& IEEE 1613 standards sustaining the high interferenceEMI / RFI environment in substations. Widelyoperational temperature capacity and GOOSEcompliance ensure the switch runtime among theharsh environment of substation. They are also good atrail train on-board network where the power input is100VDC.Industrial IEC 61850-3 SwitchesIES-2224-2P24 10/100TX + 2 1000 SFPIndustrial L2 Plus Managed SwitchIEC 61850 features include:IES-22812F-2P12 100FX + 8 10/100TX + 2 1000 SFPIndustrial L2 Plus Managed SwitchData Modeling -- Primary process objects as well as protection and control functionality in the substation is modeled into different standardlogical nodes which can be grouped under different logical devices. There are logical nodes for data/functions related to the logical device(LLN0) and physical device (LPHD).Reporting Schemes -- There are various reporting schemes (BRCB & URCB) for reporting data from server through a server-client relationshipwhich can be triggered based on pre-defined trigger conditions.Fast Transfer of events -- Generic Substation Event (GSE) are defined for fast transfer of event data for a peer-to-peer communication mode.This is again subdivided into GOOSE & GSSE.Setting Groups -- The setting group control Blocks (SGCB) are defined to handle the setting groups so that user can switch to any active groupaccording to the requirement.Sampled Data Transfer -- Schemes are also defined to handle transfer of sampled values using Sampled Value Control blocks (SVCB)Commands -- Various command types are also supported by IEC 61850 which include direct & select before operate (SBO) commands withnormal and enhanced securities.Data Storage-- SCL(Substation Configuration Language) is defined for complete storage of configured data of the substation in a specificformat.Pro-Ring


IES-2224-PUIES-22812F-PUHARDWARE FEATURESPort10/100TX 24 8100FX - 12 (SC)1000M SFP 2 2RS232 connector RJ-45 RJ-45Switching Fabric 8.8Gbps 8.0GbpsPacket Buffer 4Mbits 4MbitsJumbo Frame 9K (for Gigabit Ports) 9K (for Gigabit Ports)Mac Address 8K 1KFlash ROM 4Mbytes 4MbytesDRAM 32Mbytes 32MbytesPower Supply*Optional2 X VAC/VDC 100V~240V 2 X VAC/VDC 100V~240VRedundant Power ● ●17.5 Watts@VDC23 Watts@VDCPower Consumption21.5 Watts@VAC27 Watts@VACOverload Current Protection ● ●Polarity Reverse Protection ● ●Relay Contact with Alarm System ● ●Operating Temperature-40°C ~85°C-40°F ~185°F-40°C ~85°C-40°F ~185°FStorage Temperature-40°C~85°C / -40°F~185°F●●Operating Humidity5% to 95% (Non-condensing)●●Case DimensionW x D x H (unit=mm)440 x 280 x 44 440 x 280 x 44Case Protection IP30 IP30Weight 3000g 4900g19-inch Rack Mount ● ●CE/ FCC/ UL ● ●RoHS/ WEEE ● ●IEC 61850-3/ IEEE1613 Pending PendingStability Testing (Free fall/ Shock/ Vibration) ● ●MTBF 109,064 hours 89,370 hrsWarranty 5 years 5 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● ●Web Browser ● ●Telnet ● ●CLI ● ●<strong>Lantech</strong>-View ● ●●●IGMP snooping v1 v2/ IGMP query ●●●●VLAN ●●●●Port Trunk with LACP ●●●●LLDP ●●●●Port Security ● ●IP Security ● ●Login Security (RADIUS)●● ●●SNTP●● ●●SMTP●6 e-mail accounts●6 e-mail accountsBandwidth Control ● ●Flow Control ● ●Pro-Ring SystemX-Ring ● ●Dual Homing ● ●Couple Ring ● ●Central Ring - -Dual Ring - -Spanning Tree/ RSTP ● ●Port Mirror ● ●Quality of Service ● ●Class of Service ● ●System Log ● ●Relay Alarm ● ●SNMP Trap ● ●DHCP ● ●DNS Client/ Server Client/ Server Client/ ServerTFTP Firmware Update/ Backup /Resotre ● ●Configuration upload and download ● ●ifAlias - -ORDERING INFORMATION (part number)Wide Operating Temp. (-40°C~85°C)IES-2224-PU8350-715IES-22812F-PU8360-320 (MM, 2KM)8360-321 (SM, 30KM)P28


Industrial DNV Type SwitchesMeet with the maritime test criteria in DNV Type test,<strong>Lantech</strong> DNV Type approval switches ensure theswitches sustaining the harsh on-board environmentsoften founded in Ships, Crafts and Offshore platforms.The wide product line provides the complete solutionfor maritime applications.Industrial DNV Type SwitchesIES-0005T-DNV5 10/100TX Slim TypeIndustrial SwitchIEC-0101FT-DNV1 10/100TX to 100M-FXSlim Type ConverterIES-0008T-DNV8 10/100TX Slim TypeIndustrial SwitchIES-1204FT-DNV*4 10/100TX + 2 100SFPSmart Industrial EthernetSwitch w/Pro-RingIES-0104FT-DNV*4 10/100TX + 1 100FXIndustrial SwitchIES-0204FT-DNV*4 10/100TX + 2 100FXIndustrial SwitchPro-Ring


Industrial DNV Type SwitchesMeet with the maritime test criteria in DNV Type test,<strong>Lantech</strong> DNV Type approval switches ensure theswitches sustaining the harsh on-board environmentsoften founded in Ships, Crafts and Offshore platforms.The wide product line provides the complete solutionfor maritime applications.IES-2208F-DNV*8 10/100TX + 2 100FXManaged Industrial Switchw/Pro-RingIGS-2404-E-DNV*4 10/100/1000T + 4100/1000 Dual SpeedIES-2008A-DNV*8 10/100TX w/ Pro-RingManaged IndustrialSwitchLGS-2816C-RPS-DNV*16 100/1000M SFP+ 810/100/1000T/Dual Speed SFPCombo L2 Plus Managed Switch w/Redundant Power SupplyPro-Ring


HARDWARE FEATURESPortIES-0005T-DNV IES-0008T-DNV IEC-0101FT-DNV IES-0104FT-DNV IES-0204FT-DNV IES-1204FT-DNV10/100TX 5 8 1 4 4 4100FX - - 1 (SC or ST) 1 (SC) 2 (SC) -100M SFP - - - - - 210/100/1000T/Dual Speed SFP Combo - - - - - -RS232 connector - - - - - -Switching Fabric 1.0Gbps 1.6Gbps - 1.0Gbps 1.2Gbps 1.2GbpsPacket Buffer 448Kbits 448Kbits - 448Kbits 448Kbits 1MbitsJumbo Frame - - - - - -Mac Address 2K 2K 2K 2K 2K 2KFlash ROM - - - - - -DRAM - - - - - -Power Supply 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)Redundant Power ● ● ● ● ● ●Power Consumption 2.93 Watts 4.71 Watts 2.74 Watts 4.44 Watts 6.41 Watts 7 WattsOverload Current Protection ● ● ● ● ● ●Polarity Reverse Protection ● ● ● ● ● ●Relay Contact with Alarm System ● ● ● ● ● ●Standard Operating Temperature-20°C~60°C / -4°F~140°F- - - - - -Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● -40°C~70°CStorage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ●Case DimensionW x D x H (unit=mm)30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 26.1 x 95 x 144.3Case Protection IP30 IP30 IP30 IP30 IP30 IP30Weight 430g 480g 600g 800g 810g 395gDIN Rail Installation ● ● ● ● ● ●Wall Mount Installation ● ● ● ● ● ●19-inch Rack Mount - - - - - -CE/ FCC/ UL ● ● ● CE/ FCC CE/ FCC CE/ FCCRoHS/ WEEE ● ● ● ● ● ●UL Class I Division II Certification ● ● ● - - -DNV Type Approved ● ● ● Pending Pending PendingStability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● -MTBF 412,590 hours 388,566 hours 405,486 hours 380,717 hours 347,014 hours -Warranty 5 years 5 years 5 years 5 years 5 years 5 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3Web BrowserTelnetCLI -<strong>Lantech</strong>-View●●●●IGMP snooping v1 v2/ IGMP query -VLANPort Based VLANPort Trunk with LACP -LLDP●Port Security●IP Security -Login Security (RADIUS) -SNTP●SMTP●Bandwidth Control -Flow Control●Pro-Ring SystemX-Ring●Dual Homing●Couple Ring●Spanning Tree/ RSTP●Port Mirror -Quality of Service●Class of Service●System Log●Relay Alarm●SNMP Trap●DHCPClientDNS Client/ Server -TFTP Firmware Update/ Backup /Resotre●Configuration upload and download -ifAlias -P31ORDERING INFORMATION (part number)IES-0005T-DNV IES-0008T-DNV IEC-0101FT-DNV IES-0104FT-DNV IES-0204FT-DNV IES-1204FT-DNV8350-025DNV8350-023DNV(SC, MM, 2KM)8350-335DNV8350-336DNV(MM, 2KM)8350-345DNV8350-346DNV(MM, 2KM)-40°C~75°C, DNV type8350-632DNV 8350-621DNV 8350-004DNV(ST, MM, 2KM)(SM, 30KM) - (SM, 30KM) -8350-1208DNV8350-005DNV(SC, MM, 5KM)- -8350-026DNV(ST, MM, 5KM)- -8350-025DNV-AC(SC, SM, 30KM)8350-335DNV-AC (MM, 2KM) 8350-345DNV-AC (MM, 2KM)8350-023DNV-AC(SC, MM, 2KM)8350-336DNA-AC2KM) 8350-346DNV-AC-40°C~75°C, AC input, DNV type 8350-632DNV-AC 8350-621DNV-AC8350-004DNV-AC(ST, MM, 2KM)(SM, 30KM) - (SM, 30KM) -8350-1208DNV-AC8350-005DNV-AC(SC, MM, 5KM)(ST, MM, 5KM)- -


HARDWARE FEATURESPortIES-2208F-DNV IES-2008A-DNV IES-2216C-DNV IGS-2404-E-DNV LGS-2816C-RPS-DNV LGS-2624C-DNV10/100TX 8 8 16 - - Max 24100FX 2 (SC) / 2(ST) - - - - -10/100/1000T 20100M SFP - - - - 16(1000M)Dual Speed SFP -1000M SFP - - - 210/100/1000T/1000M SFP Combo - - 2 4 8(Dual Speed SFP) 4RS232 connector RJ-45 RJ-45 RJ-45 RJ-45 DB-9 Female RJ-45Switching Fabric 1.6Gbps 5.6Gbps 7.2Gbps 16Gbps 48GbpsPacket Buffer 1Mbits 1Mbits 1Mbits 1Mbits 1392KBJumbo Frame - - - - 9K 9K (for Gigabit Ports)Mac Address 8K 8K 8K 8K 8K 8KFlash ROM 4Mbytes 4Mbytes 4Mbytes 4Mbytes 128M -DRAM 32Mbytes 32Mbytes 32Mbytes 32Mbytes 512M -Power Supply*Optional24~48VDC 24~48VDC 24~48VDC 24~48VDC100~240VAC,50/60HzRedundant Power ● ● ● ● 12+VDC -Power Consumption 11.28 Watts 8.8 Watts 10 Watts 15.4 Watts 40 Watts 22.73 WattsOverload Current Protection ● - ● - - -Polarity Reverse Protection ● ● ● ● - -Relay Contact with Alarm System ● ● ● ● - -100~240VAC,50/60HzStandard Operating Temperature-20°C~60°C / -4°F~140°F- - - - ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● -Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● - -Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● 10%~90%Case DimensionW x D x H (unit=mm)72 x 105 x 152 72 x 105 x 152 72 x 105 x 152 59.6 x 105 x 152 442 x 209 x 44 442 x 170 x 44Case Protection IP30 IP30 IP30 IP31 - -Weight 1000g 1302g 1049g 900g 2900g -DIN Rail Installation ● ● ● ● - -Wall Mount Installation ● ● ● ● - -19-inch Rack Mount - - - - - -CE/ FCC/ UL ● ● ● ● CE/ FCC CE/FCCRoHS/ WEEE ● ● ● ● ● -UL Class I Division II Certification ● - ● ● - -DNV Type Approved Pending Pending ● Pending Pending PendingStability Tests (Free fall/ Shock/ Vibration) ● ● ● ● - -MTBF 232,194 hours 272,761 hours 220,111 hours 289,385 hours - -Warranty 5 years 5 years 5 years 5 years 2 years 2 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● ● ● ● ● ●Web Browser ● ● ● ● ● ●Telnet ● ● ● ● ● ●CLI ● ● ● ● ● ●<strong>Lantech</strong>-View ● ● ● ● - --IGMP snooping v1 v2/ IGMP query ● ● v1 v2 v3 ● ● ●VLAN ● ● ● ● ● ●Port Trunk with LACP ● ● ● ● ● ●LLDP ● ● ● ● ● ●Port Security ● ● ● ● ● ●IP Security ● ● ● ● ● ●Login Security (RADIUS) ● ● ● ● ● ●SNTP ● ● ● ● NTP ●SMTP 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accountsBandwidth Control ● ● ● ● ● ●Flow Control ● ● ● ● ● ●Pro-Ring SystemX-Ring ● ● ● ● - -Dual Homing ● ● ● ● - -Couple Ring ● ● ● ● - -Spanning Tree/ RSTP ● ● ● ● STP/ RSTP/MSTP STP/ RSTP/MSTPPort Mirror ● ● ● ● ● ●Quality of Service ● ● ● ● ● ●Class of Service ● ● ● ● ● ●System Log ● ● ● ● ● ●Relay Alarm ● ● ● ● - ●SNMP Trap ● ● ● ● ● ●DHCP Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server ClientDNS Client/ Server ● ● ● ● ● -TFTP Firmware Update/ Backup /Resotre ● ● ● ● ● ●Configuration upload and download ● ● ● ● ● ●ifAlias ● ● ● - - -ORDERING INFORMATION (part number)IES-2208F-DNV IES-2008A-DNV IES-2216C-DNV IGS-2404-E-DNV LGS-2816C-RPS-DNV LGS-2624C-DNV-20°C~60°C - - - - - 8370-6008350-419DNV(SC, MM, 2KM)-40°C~75°C, DNV type8350-418DNV8350-2312DNV 8350-655DNV 8350-850DNV 8370-900DNV(SC, SM, 30KM)-P32


Industrial UL C1D2 Switches<strong>Lantech</strong> UL Class I Division II series switches canovercome hazardous environments like gas station,mining where flammable gases, vapors, liquids,combustible dusts exist. These series can be safelydeployed in hazardous or explosive condition withoutincreasing the risk of explosion or accelerating thedamage if an accident occurs.Industrial UL C1D2 SwitchesIES-0005T5 10/100TX Slim TypeIndustrial SwitchIGS-0008T8 10/100/1000TIndustrial SwitchIES-0008T8 10/100TX Slim TypeIndustrial SwitchIGC-0101GB10/100/1000T to Mini-GBICIndustrial Switch ConverterIEC-0101FT1 10/100TX to 100M-FXSlim Type ConverterIPES-0008-48 10/100TX w/4 PoE Injector24~48VDC Industrial Switch- UL508- 24~48VDC Power InputULC1D2IP30 -40°Cto+75°CRedundantPower Supply9-56V *5YearsWarrantyTechnology Highlights:Classifications Description:Class I, Div.1-Where ignitable concentrations of flammable gases, vapours or liquids are present withinthe atmosphere under normal operation conditions.Class I, Div.2-Where ignitable concentrations of flammable gases, vapours or liquids are present withinthe atmosphere under abnormal operation conditions.Class II, Div.1-Where ignitable concentrations of combustible dusts are present within the atmosphereunder normal operation conditions.Class II, Div.2-Where ignitable concentrations of combustible dusts are present within the atmosphereunder abnormal operation conditions.Class III, Div.1-Where easily ignitable fibres or materials producing combustible flyings are presentwithin the atmosphere under normal operation conditionsClass III, Div.2-Where easily ignitable fibres or materials producing combustible flyings are presentwithin the atmosphere under abnormal operation conditionsP33


Industrial UL C1D2 Switches<strong>Lantech</strong> UL Class I Division II series switches canovercome hazardous environments like gas station,mining where flammable gases, vapors, liquids,combustible dusts exist. These series can be safelydeployed in hazardous or explosive condition withoutincreasing the risk of explosion or accelerating thedamage if an accident occurs.IGS-2206C6 10/100/1000T + 210/100/1000T/Dual SpeedSFP Combo Industrial SwitchIES-2208F8 10/100TX +2 100FX ManagedIndustrial SwitchIGS-2404-E4 10/100/1000T + 4100/1000 Dual Speed SFPManaged Industrial Switch- UL508IES-2307C7 10/100TX + 3 10/100/1000T with100/1000M SFP Combo IndustrialManaged Switch- with DIDOIES-2216C16 10/100TX + 2 10/100/1000T/DualSpeed SFP Combo Industrial SwitchIndustrial UL C1D2 SwitchesULC1D2Pro-Ring


HARDWARE FEATURESPortIES-0005T IES-0008T IEC-0101FT IGS-0008T IGC-0101GB IPES-0008-410/100TX 5 8 1 - - 8100FX - - 1 (SC or ST) - - -1000FX - - - - - -10/100/1000T - - - 8 1 -100M SFP - - - - 1 -1000M SFP - - - - - -10/100/1000T/Dual Speed SFP Combo - - - - - -RS232 connector - - - - - -PoE Injector - - - - - 8Switching Fabric 1.0Gbps 1.6Gbps - 16Gbps - 1.6GbpsPacket Buffer 448Kbits 448Kbits - 192Kbytes - 56KbytesJumbo Frame - - - 9.6Kbytes 9Kbytes -Mac Address 2K 2K 2K 8K 2K 2KFlash ROM - - - - - -DRAM - - - - - -Power Supply24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)24/ 48VDC*Optional12~36VAC*12~36VAC*12~36VAC*12~36VAC*12~36VAC*Redundant Power ● ● ● ● ● ●Power Consumption 2.93 Watts 4.71 Watts 2.74 Watts 7.39 Watts @ 48V 5.3 Watts 1.9/ 2.4 WattsOverload Current Protection ● ● ● ● ● ●Polarity Reverse Protection ● ● ● ● ● Polarity ProtectionRelay Contact with Alarm System ● ● ● ● ● ●DIDO (Digital Input/ Digital Output) - - - - -Standard Operating Temperature-20°C~60°C / -4°F~140°F● ● ● ● ● -Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● ●Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ●Case DimensionW x D x H (unit=mm)30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 48.6 x 140 x 95Case Protection IP30 IP30 IP30 IP30 IP30 IP30Weight 430g 480g 600g 500g 600g 670gDIN Rail Installation ● ● ● ● ● ●Wall Mount Installation ● ● ● ● ● ●19-inch Rack Mount - - - - - -CE/ FCC/ UL ● ● ● ● ● ●RoHS/ WEEE ● ● ● ● ● ●UL Class I Division II Certification ● ● ● ● ● ●DNV Type Approved ● ● ● - - -EN50155 - - - - - -IEC 61850 - - - - - -Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● ●MTBF 412,590 hours 388,566 hours 405,486 hours 585,810 hours 525,424 hours 241,413 hoursWarranty 5 years 5 years 5 years 5 years 5 years 5 yearsORDERING INFORMATION (part number)IES-0005T IES-0008T IEC-0101FT IGS-0008T IGC-0101GB IPES-0008-48350-020 (SC,MM,2KM)8350-022 (ST,MM,2KM)-20°C~60°C8350-630 8350-6208350-002 (SC,MM,5KM)8350-003 (ST,MM,5KM)8350-8308350-050-8350-021 (SC,SM,30KM)8350-020-AC (SC,MM,2KM)8350-022-AC (ST,MM,2KM)-20°C~60°C, AC input8350-630-AC8350-620-AC8350-002-AC (SC,MM,5KM)8350-003-AC (ST,MM,5KM)8350-830-AC8350-050-AC-8350-021-AC (SC,SM,30KM)8350-025 (SC,MM,2KM)8350-023 (ST,MM,2KM)-40°C~75°C8350-632 8350-6218350-004 (SC,MM,5KM)8350-005 (ST,MM,5KM)8350-8318350-0558450-5608350-026 (SC,SM,30KM)8350-025-AC (SC,MM,2KM)8350-023-AC (ST,MM,2KM)-40°C~75°C, AC input8350-632-AC8350-621-AC8350-004-AC (SC,MM,5KM)8350-005-AC (ST,MM,5KM)8350-831-AC8350-055-AC-8350-026-AC (SC,SM,30KM)8350-025DNV (SC,MM,2KM)8350-023DNV (ST,MM,2KM)-40°C~75°C, DNV Type8350-632DNV8350-621DNV8350-004DNV (SC,MM,5KM)8350-005DNV (ST,MM,5KM)----8350-026DNV (SC,SM,30KM)8350-025DNV-AC (SC,MM,2KM)8350-023DNV-AC (ST,MM,2KM)-40°C~75°C, DNV Type, AC input8350-632DNV-AC8350-621DNV-AC8350-004DNV-AC (SC,MM,5KM)8350-005DNV-AC (ST,MM,5KM)----8350-026DNV-AC (SC,SM,30KM)P35


HARDWARE FEATURESPortIGS-2206C IGS-2404-E IES-2208F IES-2216C IES-2307C10/100TX - - 8 16 7100FX - - 2 (SC) - -1000FX - - - - -10/100/1000T 6 4 - - -100M SFP - 4 (Dual Speed) - - -1000M SFP - - - - -10/100/1000T/Dual Speed SFP Combo 2 - - 2 3RS232 connector RJ-45 RJ-45 RJ-45 RJ-45 RJ-45PoE Injector - - - - -Switching Fabric 16Gbps 16Gbps 1.6Gbps 7.2Gbps 7.4GbpsPacket Buffer 1Mbits 1Mbits 1Mbits 1Mbits 1MbitsJumbo Frame - 9K (for Gigabit Ports) - - -Mac Address 8K 8K 8K 8K 8KFlash ROM 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4MbytesDRAM 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32MbytesPower Supply*Optional24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)Redundant Power ● ● ● ● ●Power Consumption 18 Watts 17 Watts 11.28 Watts 10 Watts 10.2 WattsOverload Current Protection - - ● ● ●Polarity Reverse Protection ● ● ● ● ●Relay Contact with Alarm System ● ● ● ● ●DIDO (Digital Input/ Digital Output) - - - - 2/2Standard Operating Temperature-20°C~60°C / -4°F~140°F● - ● ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ●Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ●Case Dimension72 x 105 x 15272 x 105 x 152W x D x H (unit=mm)59.6 x 105 x 152 (-E)72 x 105 x 152 72 x 105 x 152 72 x 105 x 152Case Protection IP30 IP30 IP30 IP30 IP30Weight 1418g 1250g 1000g 1049g 1300gDIN Rail Installation ● ● ● ● ●Wall Mount Installation ● ● ● ● ●19-inch Rack Mount - - - - -CE/ FCC/ UL ● ● ● ● ●RoHS/ WEEE ● ● ● ● ●UL Class I Division II Certification ● ● ● ● ●DNV Type Approved - - Pending ● -EN50155 - - - - -IEC 61850 - - - - -Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ●MTBF 248,507 hours 286,945 hours 232,194 hours 220,111 hours 260,818 hoursWarranty 5 years 5 years 5 years 5 years 5 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● ● ● ● ●Web Browser ● ● ● ● ●Telnet ● ● ● ● ●CLI ● ● ● ● ●<strong>Lantech</strong>-View ● ● ● ● ●Menu Driven Optional - - - -IGMP snooping v1 v2/ IGMP query ● ● ● v1 v2 v3 ●VLAN ● ● ● ● ●Port Trunk with LACP ● ● ● ● ●LLDP ● ● ● ● ●Port Security ● ● ● ● ●IP Security ● ● ● ● ●Login Security (RADIUS) ● ● ● ● ●SNTP ● ● ● ● ●SMTP 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accountsBandwidth Control ● ● ● ● ●Flow Control ● ● ● ● ●Pro-Ring SystemX-Ring ● ● ● ● ●Dual Homing ● ● ● ● ●Couple Ring ● ● ● ● ●Central Ring - - - - -Dual Ring - - - - ●Spanning Tree/ RSTP ● ● ● ● ●Port Mirror ● ● ● ● ●Quality of Service ● ● ● ● ●Class of Service ● ● ● ● ●System Log ● ● ● ● ●Relay Alarm ● ● ● ● ●SNMP Trap ● ● ● ● ●DHCP Client/ Server Client/ Server Client/ Server Client/ Server Client/ ServerDNS Client/ Server ● ● ● ● ●TFTP Firmware Update/ Backup /Resotre ● ● ● ● ●Configuration upload and download ● ● ● ● ●ifAlias - - ● ● ●ORDERING INFORMATION (part number)IGS-2206C IGS-2404-E IES-2208F IES-2216C IES-2307C-20°C~60°C-8350-6048350-8008350-410 (SC, MM, 2KM)8350-412 (ST, MM, 2KM)8350-415 (SC, SM, 30KM)8350-6508350-460-40°C~75°C8350-640 8350-8508350-411 (SC, MM, 2KM)8350-413 (ST, MM, 2KM)8350-416 (SC, SM, 30KM)8350-6558350-465-40°C~75°C, DNV Type---8350-419DNV (SC, MM)8350-418DNV (SC, SM)8350-655DNV -P36


Industrial Managed Switches<strong>Lantech</strong> SNMP managed switches offer advancedfunctions to cover most of the network requirements.Each model also supports Pro-Ring system which isself-heal recovery scheme in 10 ms.Industrial Managed SwitchesIES-2008A8 10/100TX ManagedIndustrial SwitchIES-2208F8 10/100TX +2 100FX ManagedIndustrial SwitchIES-2206F-II6 10/100TX + 2 100FX IndustrialManaged SwitchIES-2216C16 10/100TX + 2 10/100/1000T/DualSpeed SFP Combo Industrial SwitchIES-2208C8 10/100TX + 2 10/100/1000T/Dual Speed SFP Combo IndustrialSwitchIES-2307C7 10/100TX + 3 10/100/1000T with100/1000M SFP Combo IndustrialManaged Switch- with DIDOTechnology Highlights:What is the SNMP?Simple Network ManagementProtocol (SNMP) is theprotocol governing networkmanagement and themonitoring of network deviceand their functions.There are 3rd party NMSsoftware are available in themarket for central networkmanagement, such as HPopen view, SNMPC, what’s upGold,etc.IES-2307C with Digital Input/OutputThe IES-2307C Industrial Switch contains additionally two digital outputs and two digital inputs.Outputs are open-collector transistor switches that may be controlled by the host computer. Theyprovide messages, which can be applied to heaters, pumps, and other electrical equipment. Thedigital inputs may be read by the host computer and used to sense the state of a remote digital signal.DIDO SNMP trapRespondPro-Ring


Industrial Managed Switches<strong>Lantech</strong> SNMP managed switches offer advancedfunctions to cover most of the network requirements.Each model also supports Pro-Ring system which isself-heal recovery scheme in 10 ms.IES-2307CI7 10/100TX + 3 10/100/1000Twith 100/1000M SFP ComboIndustrial Managed Switch withDIDO and Internal Power SupplyLES-2400-RPS3 slots 10/100M Modularized + 2 xGigabit Combo L2 Plus ManagedSwitch w/Redundant Power SupplyType Industrial Switch- 2 Years WarrantyIES-2307CFR7 10/100TX+3 10/100/1000Twith 100/1000 SFP comboIndustrial managed switch with2 redundant fiberLGS-2816C-RPS16 100/1000M SFP +8 10/100/1000T/Dual Speed SFPCombo L2 Plus Managed Switchw/Redundant Power Supply(-20°C~60°C)IGS-2404-E4 10/100/1000T + 4 100/1000Dual Speed SFP ManagedIndustrial Switch /w Pro-Ring II- UL C1D2- UL508LGS-2624C20 10/100/1000T + 4 100/1000MSFP Combo + 2 100/1000M SFP L2Plus Managed Switch(-20°C~60°C)IGS-2206C6 10/100/1000T + 210/100/1000T/Dual Speed SFPCombo Industrial Switch- UL C1D2Industrial Managed SwitchesPro-Ring


HARDWARE FEATURESPortIES-2008A IES-2206F-II IES-2208C IES-2208F IES-2216C IES-2307C10/100TX 8 6 8 8 16 7100FX - 2 (SC) - 2 (SC) - -1000FX - - - - - -10/100/1000T - - - - - -100M SFP - - - - - -1000M SFP - - - - - -10/100/1000T/Dual Speed SFP Combo - - 2 - 2 3RS232 connector RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 RJ-45PoE Injector - - - - - -Switching Fabric 5.6Gbps 1.6Gbps 5.6Gbps 1.6Gbps 7.2Gbps 7.4GbpsPacket Buffer 1Mbits 1Mbits 1Mbits 1Mbits 1Mbits 1MbitsJumbo Frame - - - - - -Mac Address 8K 8K 8K 8K 8K 8KFlash ROM 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4MbytesDRAM 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32MbytesPower Supply*Optional24~48VDC 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)Redundant Power ● ● ● ● ● ●Power Consumption 8.8 Watts 9 Watts 9.5 Watts 11.28 Watts 10 Watts 10.2 WattsOverload Current Protection - ● ● ● ● ●Polarity Reverse Protection ● ● ● ● ● ●Relay Contact with Alarm System ● ● ● ● ● ●DIDO (Digital Input/ Digital Output) - - - - - 2/2Standard Operating Temperature-20°C~60°C / -4°F~140°F● ● ● ● ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● ●Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ●Case DimensionW x D x H (unit=mm)72 x 105 x 152 52 x 106 x 144 72 x 105 x 152 72 x 105 x 152 72 x 105 x 152 72 x 105 x 152Case Protection IP30 IP30 IP30 IP30 IP30 IP30Weight 1302g 735g 1302g 1000g 1049g 1300gDIN Rail Installation ● ● ● ● ● ●Wall Mount Installation ● ● ● ● ● ●19-inch Rack Mount ● - ● ● ● MBAK19001CE/ FCC/ UL CE/ FCC CE/ FCC ● ● ● ●RoHS/ WEEE ● ● ● ● ● ●UL Class I Division II Certification - - - ● ● ●Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● ●MTBF 272,761 hours 232,194 hours 272,761 hours 232,194 hours 220,111 hours 260,818 hoursWarranty 5 years 5 years 5 years 5 years 5 years 5 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● ● ● ● ● ●Web Browser ● ● ● ● ● ●Telnet ● ● ● ● ● ●CLI ● ● ● ● ● ●<strong>Lantech</strong> View /<strong>Lantech</strong>-View Pro ● <strong>Lantech</strong> View ● ● ● ●Menu Driven - - - - - -IGMP snooping v1 v2/ IGMP query ● ● ● ● ● ●VLAN ● ● ● ● ● ●Port Trunk with LACP ● ● ● ● ● ●LLDP ● ● ● ● ● ●Port Security ● ● ● ● ● ●IP Security ● ● ● ● ● ●Login Security (RADIUS) ● ● ● ● ● ●SNTP ● ● ● ● ● ●SMTP 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accountsBandwidth Control ● ● ● ● ● ●Flow Control ● ● ● ● ● ●Pro-Ring SystemX-Ring ● ● ● ● ● ●Dual Homing ● ● ● ● ● ●Couple Ring ● ● ● ● ● ●Central Ring - - - - - -Dual Ring ● - ● - - ●Spanning Tree/ RSTP ● STP/ RSTP/ MSTP ● ● ● ●Port Mirror ● ● ● ● ● ●Quality of Service ● ● ● ● ● ●Class of Service ● ● ● ● ● ●System Log ● ● ● ● ● ●Relay Alarm ● ● ● ● ● ●SNMP Trap ● ● ● ● ● ●DHCP Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server Client/ ServerDNS Client/ Server ● ● ● ● ● ●TFTP Firmware Update/ Backup /Resotre ● ● ● ● ● ●Configuration upload and download ● ● ● ● ● ●ifAlias ● ● ● ● ● ●ORDERING INFORMATION (part number)-IES-2008A IES-2206F-II IES-2208C IES-2208F IES-2216C IES-2307C-20°C~60°C-40°C~75°CP398350-23028350-2208 (MM, 2KM)8350-2258 (SM, 30KM)8350-450-8350-2218 (MM, 2KM)8350-2312 8350-4408350-2268 (SM, 30KM)8350-410 (SC, MM, 2KM)8350-412 (ST, MM, 2KM)8350-415 (SC, SM, 30KM)8350-411 (SC, MM, 2KM)8350-413 (ST, MM, 2KM)8350-416 (SC, SM, 30KM)8350-650 8350-4608350-655 8350-465


HARDWARE FEATURESPortIES-2307CI IES-2307CFR IGS-2206C IGS-2404-E LES-2400-RPS LGS-2816C-RPS LGS-2624C10/100TX 7 7 - - Max 24 - 24100FX - - - - Max 24 - -1000FX - - - - - - -10/100/1000T - - 6 4 - - 20100M SFP - - - Max 24 -1000M SFP - - -4 (Dual Speed)-16 (Dual Speed SFP)210/100/1000T/Dual Speed SFP Combo 3 3 2 - 2 8 (Dual Speed SFP) 4RS232 connector RJ-45 RJ-45 RJ-45 RJ-45 DB-9 Female DB-9 Female RJ-45PoE Injector - - - - - - -Switching Fabric 7.4Gbps 7.4Gbps 16Gbps 16Gbps 8.8Gbps 48Gbps -Packet Buffer 1Mbits 1Mbits 1Mbits 1Mbits 4Mbits 1392KB -Jumbo Frame - - - 9K (for Gigabit Ports) 9K (for Gigabit Ports) 9K 9K (for Gigabit Ports)Mac Address 8K 8K 8K 8K 8K 8K 8KFlash ROM 4Mbytes 4Mbytes 4Mbytes 4Mbytes - 128M -DRAM 32Mbytes 32Mbytes 32Mbytes 32Mbytes - 512M -Power Supply*Optional100~240VAC,24VDC (9~56VDC)24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)100~240VAC,50/60Hz100~240VAC,50/60HzRedundant Power ● ● ● ● 12~48VDC 12+VDC -Power Consumption 10.2 Watts 10.2 Watts 18 Watts 17 Watts 18 Watts 40 Watts 22.73 WattsOverload Current Protection ● ● - - - - -Polarity Reverse Protection ● ● ● ● - - -Relay Contact with Alarm System ● ● ● ● - - -DIDO (Digital Input/ Digital Output) 2/2 2/2 - - - - -100~240VAC,50/60HzStandard Operating Temperature-20°C~60°C / -4°F~140°F● ● ● - ● ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● - - -Storage Temperature-40°C~70°C● ● ● ●-40°C~85°C / -40°F~185°F-40°F~158°F- -Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ● 10%~90%Case Dimension72 x 105 x 152217 x141x 66 217 x141x 66 72 x 105 x 152W x D x H (unit=mm)59.6 x 105 x 152 (-E)440 x 200 x 44 442 x 209 x 44 442 x 170 x 44Case Protection IP30 IP30 IP30 IP30 - - -Weight 1300g 1300g 1418g 1250g 5000g 2900g -DIN Rail Installation ● ● ● ● - - -Wall Mount Installation - - ● ● - - -19-inch Rack Mount ● ● - - ● ● ●CE/ FCC/ UL CE/FCC CE/FCC ● ● ● CE/ FCC CE/ FCCRoHS/ WEEE ● ● ● ● ● ● ●UL Class I Division II Certification - - ● ● - - -Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● - - -MTBF - - 248,507 hours 286,945 hours 75,900 hours - -Warranty 5 years 5 years 5 years 5 years 2 years 2 years 2 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● ● ● ● ● ● ●Web Browser ● ● ● ● ● ● ●Telnet ● ● ● ● ● ● ●CLI ● ● ● ● ● ● ●<strong>Lantech</strong>-View Pro - - ● ● - - -Menu Driven - - Optional - - - -IGMP snooping v1 v2/ IGMP query ● ● ● ● ● ● ●VLAN ● ● ● ● ● ● ●Port Trunk with LACP ● ● ● ● ● ● ●LLDP ● ● ● ● ● ● ●Port Security ● ● ● ● ● ● ●IP Security ● ● ● ● ● ● ●Login Security (RADIUS) ● ● ● ● ● ● ●SNTP ● ● ● ● ● NTP ●SMTP 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accountsBandwidth Control ● ● ● ● ● ● ●Flow Control ● ● ● ● ● ● ●Pro-Ring SystemX-Ring ● ● ● ● ● - -Dual Homing ● ● ● ● ● - -Couple Ring ● ● ● ● ● - -Central Ring - - - - - - -Dual Ring ● ● - - - - -Spanning Tree/ RSTP ● ● ● ● STP/ RSTP/ MSTP (Optional) STP/ RSTP/ MSTP STP/ RSTP/MSTPPort Mirror ● ● ● ● ● ● ●Quality of Service ● ● ● ● ● ● ●Class of Service ● ● ● ● ● ● ●System Log ● ● ● ● ● ● ●Relay Alarm ● ● ● ● - - ●SNMP Trap ● ● ● ● ● ● ●DHCP Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server ClientDNS Client/ Server ● ● ● ● ● ● -TFTP Firmware Update/ Backup /Resotre ● ● ● ● ● ● ●Configuration upload and download ● ● ● ● ● ● ●ifAlias ● ● - - - - -ORDERING INFORMATION (part number)IES-2307CI IES-2307CFR IGS-2206C IGS-2404-E LES-2400-RPS LGS-2816C-RPS LGS-2624C-20°C~60°C-8350-4678350-6048350-8008220-6008370-900 8370-600-40°C~75°C8350-4688350-6408350-850 --P40


Industrial PoE SwitchesFully compliant with IEEE 802.3at PoE standard,<strong>Lantech</strong> Industrial PoE Switches providecomprehensive PoE solution with durability andreliability. Besides standard 802.3at products, <strong>Lantech</strong>also offer non-standard passive Mode B PoE switch fornon-standard power deviced.Industrial PoE SwitchesIPEC-0101FT1 10/100TX to 100M-FX Slim TypeMedia Converter w/PoE injector- 802.3afIPES-0104FT4 10/100TX + 1 100FX w/4 PoEInjector Industrial Switch- 802.3afIPES-0005T-45 10/100TX w/4 PoE InjectorIndustrial Switch- 802.3afIPES-0005T-4-H5 10/100TX w/ 4 High PowerPoE Industrial EthernetSwitch- 802.3afIPES-0005T-4B5-Port 10/100TX with 4 PoEMode B Passive InjectorIndustrial Switch-24~48VDC Power InputIP30 -40°Cto+75°CIES-0005T-PoE5 10/100TX Slim TypeIndustrial Switch with onePoE Industrial Switch-24~48VDC Power InputPoE mode BRedundantPower Supply45-56VDC5YearsWarrantyP41Technology Highlights:What is the difference between Mode A and Mode B?In mode A, pins 1 and 2 form one side of the 48 VDC, and pins 3 and 6form the other side. These are the same two pairs used for datatransmission in 10BASE-T and 100BASE-TX, allowing the provision of bothpower and data over only two pairs in such networks.The free polarity allows PoE to accommodate for crossover cables, patchcables and auto-MDIX.In mode B, pins 4-5 form one side of the DC supply and pins 7-8 providethe return; these are the "spare" pairs in 10BASE-T and 100BASE-TX. ModeB, therefore, requires a 4-pair cable.What is the difference between Passive PoE and Active PoE ?Active PoE has active PoE driving components inside from chip vendors likeTI, Microsemi etc and it is able to transfer power up to 100 meters. PassivePoE uses free wires in the Ethernet cable and sends the equipments poweralong them to the far end up to 100 meters. However, the longer thedistance, the greater power it will consume.Mode A and Mobe B :PINS onMode AMode BSwitch Ethernet PoE(DC) Ethernet PoE(DC)Pin1 Tx ┼ TxPin2 Tx ┼ TxPin3 Rx ― RxPin4 None None ┼Pin5 None None ┼Pin6 Rx ― RxPin7 None None ―Pin8 None None ―Active PoE and Passive PoE :Active PoEPassive PoEPin Assignment Ethernet-TypeIP CAM802.3af/at (48VDC)IP CAMNon-standard,(24VDC)hand-shakingfeeding-PowerPoE Switch802.3af/at (48VDC)PassivePoE Switch(24VDC)


(24Industrial PoE SwitchesFully compliant with IEEE 802.3af/at PoE standard,<strong>Lantech</strong> Industrial PoE Switches providecomprehensive PoE solution with durability andreliability. Besides standard 802.3af/at products,<strong>Lantech</strong> also offer non-standard passive Mode B PoEswitch for non-standard power deviced.IPES-0008-4*8 10/100TX w/4 PoE Injector24~48VDC Industrial Switch- UL508- 24~48VDC Power Input- 802.3afIPES-2208GF-678 10/100TX + 2 1000FX M12 /IP67 Managed Industrial Switchw/8 PoE 802.3af Injectors-UL508 / UL C1D2Technology Highlights:PoE 802.3af & 802.3atIEEE 802.3af provides a device selectable36~57V DC, though usually 48 V, over twoof the four available pairs on a Cat. 3/Cat.5e cable, with a selectable current of10–400 mA subject to a maximum loadpower of 15.40 W, but only about 12.95 Ware available after counting cable losses;most AC/DC adapter will lose 10–20% ofthe available energy.IEEE 802.3atsupport higher power up to30W per port.IPES-0008-4-M12*8 10/100TX IP41 rated IndustrialSwitch w/M12 connectors and 4PoE injectors- 24~48VDC Power Input- 802.3afIPES-2208-M128 10/100TX + 2 10/100/ 1000TIP41/IP65 w/8 PoE 802.3af InjectorsIndustrial Managed SwitchPower Levels AvailableClass UsageIPES-2224C-2424 10/100TX + 2 100/1000T/SFPCombo w/24 PoE Injector Pro-RingIndustrial Managed Switch- 802.3afPro-Ring


HARDWARE FEATURESPortIPEC-0101FT IPES-0005T-4 IPES-0005T-4-H IPES-0005T-4B IPES-0005T-PoE IPES-0104FT10/100TX 1 5 5 5 5 4100FX 1 (SC) - - - - 1 (SC)1000FX - - - - - -10/100/1000T - - - - - -100M SFP - - - - - -1000M SFP - - - - - -10/100/1000T/Dual Speed SFP Combo - - - - - -RS232 connector - - - - - -PoE Injector 1 4 4 4 (Mode B) 1 (Mode B) 4 (Mode B)Switching Fabric - 1.0Gbps 1.0Gbps 1.0Gbps 1.0Gbps 1.0GbpsPacket Buffer - 448Kbits 448Kbits 448Kbits 1Mbits 448KbitsJumbo Frame - - - - - -Mac Address 2K 2K 2K 2K 2K 2KFlash ROM - - - - - -DRAM - - - - - -Power Supply*Optional48VDC (45~56VDC) 48VDC (45~56VDC) 48VDC (45~56VDC) 24VDC (12~48VDC) 24VDC (12~48VDC) 48VDC (45~56VDC)Redundant Power ● ● ● ● ● ●Power Consumption 3.3 Watts 5.4 Watts 5.4 Watts 5.4 Watts 2.93 Watts 6.6 WattsOverload Current Protection ● ● ● ● ● ●Polarity Reverse Protection Polarity Protection Polarity Protection Polarity Protection Polarity Protection Polarity Protection Polarity ProtectionRelay Contact with Alarm System ● ● ● ● ● ●DIDO (Digital Input/ Digital Output) - - - - - -Standard Operating Temperature-20°C~60°C / -4°F~140°F● ● ● ● ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● -Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ●Case DimensionW x D x H (unit=mm)30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140Case Protection IP30 IP30 IP30 IP30 IP30 IP30Weight 600g 648g 648g 648g 430g 824gDIN Rail Installation ● ● ● ● ● ●Wall Mount Installation ● ● ● ● ● ●19-inch Rack Mount - - - - - -CE/ FCC/ UL ● ● ● ● CE/FCC ●RoHS/ WEEE ● ● ● ● ● ●UL Class I Division II Certification - - - - - -Stability Testing (Free fall/ Shock/ Vibration) ● ● ● ● ● ●MTBF 391,515 hours 443,153 hours 443,153 hours 443,153 hours 412,590 hours 259,356 hoursWarranty 5 years 5 years 5 years 5 years 5 years 5 yearsORDERING INFORMATION (part number)IPEC-0101FT IPES-0005T-4 IPES-0005T-4-H IPES-0005T-4B IPES-0005T-PoE IPES-0104FT-20°C~60°C8350-900 (MM, 2KM)8350-910 8350-91028350-6338350-911 (MM, 2KM)8350-901 (SM, 30KM) 8350-912 (SM, 30KM)-20°C~60°C, High Power Model - 8350-918 - --40°C~75°C8350-905 (MM, 2KM)8350-916 8350-9162 8350-6348350-917 (MM, 2KM)8350-906 (SM, 30KM) 8350-920 (SM, 30KM)-40°C~75°C, High Power Model - 8350-919 - -P43


HARDWARE FEATURESPortIPES-0008-4 IPES-0008-4-M12 IPGS-0204G IPES-2208C IPES-2208GF-67 IPES-2208-M12 IPES-2224C-24 IPEA-0101T/R10/100TX 8 8(M12) - 8 8 (M12) 8 (M12) 24 1100FX - - - - - - - -1000FX - - - - 2 (LC) - - -10/100/1000T - - 4 - - - - -100M SFP - - - - - - - -1000M SFP - - 2 - - - - -10/100/1000T/Dual Speed SFP Combo - - - 2 - - 2 (1000M SFP only) -RS232 connector - - - RJ-45 M12 M12 DB-9 Female -PoE Injector 8 4 4 8 8(802.3af) 8(802.3af) 24 1Switching Fabric 1.6Gbps 1.6Gbps 12Gbps 5.6Gbps 5.6Gbps 5.6Gbps 8.8Gbps -Packet Buffer 56Kbytes 448Kbits 17.85 Mpps 1Mbits 1Mbits - 4Mbits -Jumbo Frame - - - - - - 9Kbytes -Mac Address 2K 2K 8K 8K 8K 8K 8K -Flash ROM - - - 4Mbytes 4Mbytes - 4Mbytes -DRAM - - - 32Mbytes 32Mbytes - 32Mbytes -Power Supply48VDC (45~56VDC)48VDC (47~58VDC)-24/ 48VDC 24/ 48VDC 48VDC (48~57V) 48VDC (45~56VDC)48VDC (45~56VDC)*Optional(M12 connector)(M12 connector)Redundant Power ● ● ● ● ● ● -Power Consumption 1.9/ 2.4 Watts 15.4 Watts 129.9Watts NA 14 Watts 10 Watts 15.76 Watts


Industrial Smart-Ring Switches<strong>Lantech</strong> Smart-Ring series provides the redundantPro-Ring 10ms protocol by enabling DIP switch orthrough Web GUI for self-healing network. Each modelalso provides smart and easy functions including Portbased VLANs, RSTP/STP, E-mail alert, SNMP Trap,DHCP, DNS client to satisfy the basic managementrequirements.Industrial smart-Ring SwitchesIES-1005T5 10/100TX Smart IndustrialEthernet Switch w/Pro-RingIES-1005T-67*5 10/100TX IP-67 SmartIndustrial Ethernet Switchw/Pro-Ring- IP67Pro-Ring


Industrial Entry Switches<strong>Lantech</strong> Industrial Entry Switches are unmanagedmodels which are designed to meet the demands ofindustrial network for Plug-and-Play usage. Each modelis in a robust IP 30 housing and has been testedextensively to meet with Industrial EMI / EMCstandards and UL safety.HARDWARE FEATURESPortIES-0005T5 10/100TX Slim TypeIndustrial SwitchIES-0216C16 10/100TX + 2 10/100/1000T/Giga or 100M SFP ComboIndustrial SwitchIES-0008T8 10/100TX Slim TypeIndustrial SwitchIGS-0008T8 10/100/1000TIndustrial SwitchIES-0104FT4 10/100TX + 1 100FXIndustrial SwitchIP30 -40°Cto+75°CIES-0204FT4 10/100TX + 2 100FXIndustrial SwitchRedundantPower Supply9-56V5YearsWarrantyIES-0005T IES-0008T IES-0104FT IES-0204FT IES-0216C IGS-0008T10/100TX 5 8 4 4 16 -100FX - - 1 (SC/ST) 2 (SC/ST) - -10/100/1000T - - - - - 810/100/1000T/Dual Speed SFP Combo - - - - 2 -Industrial Entry SwitchesSwitching Fabric 1.0Gbps 1.6Gbps 1.0Gbps 1.2Gbps 7.2Gbps 16GbpsPacket Buffer 448Kbits 448Kbits 448Kbits 448Kbits 1Mbits 192KbytesJumbo Frame - - - - - 9.6KbytesMac Address 2K 2K 2K 2K 8K 8KPower Supply*Optional24VDC (9~56VDC)12~36VAC*24VDC (9~56VDC)12~36VAC*24VDC (9~56VDC)12~36VAC*24VDC (9~56VDC)12~36VAC*24VDC (9~56VDC)12~36VAC*24VDC (9~56VDC)18~36VAC*Redundant Power ● ● ● ● ● ●Power Consumption 2.93 Watts 4.71 Watts 4.44 Watts 6.41 Watts 9 Watts 7.39 Watts @ 48VOverload Current Protection ● ● ● ● ● ●Polarity Reverse Protection ● ● ● ● ● ●Relay Contact with Alarm System ● ● ● ● ● ●Standard Operating Temperature-20°C~60°C / -4°F~140°F● ● ● ● ● ●Wide Operating Temperature-40°C~75°C / -40°F~167°F● ● ● ● ● ●Storage Temperature-40°C~85°C / -40°F~185°F● ● ● ● ● ●Operating Humidity5% to 95% (Non-condensing)● ● ● ● ● ●Case DimensionW x D x H (unit=mm)30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 72 x 105 x 152 30 x 95 x 140Case Protection IP30 IP30 IP30 IP30 IP30 IP30Weight 430g 480g 800g 810g 1300g 500gDIN Rail Installation ● ● ● ● ● ●Wall Mount Installation ● ● ● ● ● ●CE/ FCC/ UL ● ● CE/ FCC CE/ FCC ● ●RoHS/ WEEE ● ● ● ● ● ●UL Class I Division II Certification ● ● - - - ●DNV Type Approved ● ● ● ● - -Stability Testing (Free fall/ Shock/ Vibration) ● ● ● ● ● ●MTBF 412,590 hours 388,566 hours 380,717 hours 347,014 hours 243,301 hours 585,810 hoursWarranty 5 years 5 years 5 years 5 years 5 years 5 yearsORDERING INFORMATION (part number)-20°C~60°C-20°C~60°C, AC input-40°C~75°C-40°C~75°C, AC inputIES-0005T IES-0008T IES-0104FT IES-0204FT IES-0216C IGS-0008T8350-330 (MM, 2KM) 8350-340 (MM, 2KM)8350-630 8350-6208350-331 (SM, 30KM) 8350-341 (SM, 30KM)8350-6518350-8308350-330-AC (MM, 2KM)8350-340-AC (MM, 2KM)8350-630-AC8350-620-AC8350-331-AC (SM, 30KM)8350-341-AC (SM, 30KM)8350-651-AC8350-830-AC8350-335 (MM, 2KM) 8350-345 (MM, 2KM)8350-6328350-6218350-6568350-8318350-336 (SM, 30KM) 8350-346 (SM, 30KM)8350-335-AC (MM, 2KM)8350-345-AC (MM, 2KM)8350-632-AC8350-621-AC8350-656-AC8350-831-AC8350-336-AC (SM, 30KM)8350-346-AC (SM, 30KM)P46


Industrial Converters SeriesFeatured with the unique DIP switch for LLF and duplexmode, <strong>Lantech</strong> Industrial Converters provide the mostconvenient choice with reliability. Each model isdesigned to meet the demands of harsh industrialenvironments with robust IP 30 housing. The series hasalso been tested extensively to meet with EMI / EMCstandards and UL safety.Industrial Ethernet ConvertersIEC-0101FT1 10/100TX to 100M-FXSlim Type ConverterIP30-40°Cto+75°CRedundantPower Supply9-56V5YearsWarrantyHARDWARE FEATURESPortIGC-0101GB10/100/1000T to Mini-GBICIndustrial Switch ConverterIPEC-0101FT1 10/100TX to 100M-FXSlim Type Media Converterw/PoE injectorIVC-01011 10/100TX to VDSL2Industrial Converter- (Build To Order)IPEA-0101T/R1 10/100TX to 1 Coax RG6/RG11 PoEMedia Converter w/802.3afPoE injector- (Build To Order)IEC-0101FT-SC IEC-0101FT-ST IGC-0101GB IPEC-0101FT IVC-0101 IPEA-0101T/R10/100TX 1 1 - 1 1 1100FX 1 (SC) 1 (ST) - 1 (SC) - -10/100/1000T - - 1 - - -1000M SFP - - 1 - - -- - - - RJ-45*1-VDSLwith Female Phone JackPoE Injector - - - 1 - 1Jumbo Frame - - 9Kbytes - - -Mac Address 2K 2K 2K 2K - -Power Supply24VDC (9~56VDC)24VDC (9~56VDC)24VDC (9~56VDC)24VDC (9~56VDC)-48VDC (45~56VDC)*Optional12~36VAC*12~36VAC*12~36VAC*24VACRedundant Power ● ● ● ● ● -Power Consumption 2.74 Watts 2.74 Watts 5.3 Watts 3.3 Watts4.8 Watts (48VDC)7.7 Watts (24VAC)


Universal Redundant Fiber ControllerThe <strong>Lantech</strong> Universal Redundant Fiber Controllerprovides a permanent and trouble-free access port forin-line network devices. The controller automaticallyswitches network traffic through added in-line devicesor bypasses devices that are about to be removed.Prevent link failure when attached in-line devices losepower by powering the controller and in-line devicefrom the same power source.IFR-0202-LCUniversal RedundantLC Fiber Controller- (Build To Order)HARDWARE FEATURESPortIFR-0202-SCUniversal RedundantSC Fiber Controller- (Build To Order)IFR-0202-STUniversal RedundantST Fiber Controller- (Build To Order)IP30 -5°Cto+70°CRedundantPower Supply9-56V5YearsWarrantyIFR-0202-LC-MM IFR-0202-LC-SM IFR-0202-SC-MM IFR-0202-SC-SM IFR-0202-ST-MM IFR-0202-ST-SMIn-Line 2 2 2 2 2 2Network 2 2 2 2 2 2Connector Type LC LC SC SC ST STFiber Type Multi-mode Single-mode Multi-mode Single-mode Multi-mode Single-modeCorning 62.5/ 125μm 9/ 125μm 62.5/ 125μm 9/ 125μm 62.5/ 125μm 9/ 125μmWavelength 850nm 1300~1550nm 850nm 1300~1550nm 850nm 1300~1550nmInsertion LossMax 1.6dB(Bypass Mode)Max 1.6dB(Bypass Mode)Max 1.6dB(Bypass Mode)Max 1.6dB(Bypass Mode)Max 1.6dB(Bypass Mode)Max 1.6dB(Bypass Mode)Power 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)Redundant Power ● ● ● ● ● ●LED Power Status Power Status Power Status Power Status Power Status Power StatusOperating Temperature-5°C~70°C-5°C~70°C-5°C~70°C-5°C~70°C-5°C~70°C-5°C~70°C23°F~158°F23°F~158°F23°F~158°F23°F~158°F23°F~158°F23°F~158°FStorage Temperature-40°C~85°C-40°C~85°C-40°C~85°C-40°C~85°C-40°C~85°C-40°C~85°C-40°F~185°F-40°F~185°F-40°F~185°F-40°F~185°F-40°F~185°F-40°F~185°FOperating Humidity (Non-condensing) 10%~90% 10%~90% 10%~90% 10%~90% 10%~90% 10%~90%Case DimensionW x D x H (unit=mm)50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3Case Protection IP30 IP30 IP30 IP30 IP30 IP30Weight 500g 500g 500g 500g 500g 500gDIN Rail Installation ● ● ● ● ● ●Wall Mount Installation ● ● ● ● ● ●CE/ FCC/ UL ● ● ● ● ● ●RoHS/ WEEE ● ● ● ● ● ●MTBF - - - - - -Warranty 5 years 5 years 5 years 5 years 5 years 5 yearsORDERING INFORMATION (part number)*The insertion loss is less than 1dB when the switch receiving power and is in Normal modeIFR-0202-LC-MM IFR-0202-LC-SM IFR-0202-SC-MM IFR-0202-SC-SM IFR-0202-ST-MM IFR-0202-ST-SM8800-140 8800-141 8800-145 8800-146 8800-147 8800-148Universal Redundant Fiber ControllerTechnology Highlights: How does Universal Redundant Fiber Controller work?Normal statusBypass statusPower FailSwitch IFR-0202 Switch IFR-0202 Switch IFR-0202 Switch IFR-0202 Switch IFR-0202 Switch IFR-0202P48


Industrial Wireless Access PointThe <strong>Lantech</strong> high quality access point series ensure themost reliable wireless connectivity from basic IP30model to high-end IP68/65 model. The three modelsprovide different software features for comprehensivenetwork plans. All models support IEEE 802.11a/b/gstandard with PoE. Integrated with <strong>Lantech</strong> switches,we are able to provide total solutions withoutboundary.Industrial Wireless Access PointIWP-1000b/gIndustrial 802.11 b/gRedundant Access PointTechnology Highlights:What is MESH?IWP-2000-65Industrial 802.11 a/b/gIP65 Redundant Access Pointw/MESH- (Build To Order)IWP-2000-68Industrial 802.11 a/b/gIP68 Redundant Access Pointw/MESH- (Build To Order)IP 306568 5YearsWarrantyA wireless mesh network is a communications network which often consists of mesh clients, mesh routers and gateways. A mesh networkis reliable and offers redundancy securely and cost effectively for enterprises and end users. When one node can no longer operate, therest of the nodes can still communicate with each other, directly or through one or more intermediate nodes. In areas that do not supporta wired backhaul, <strong>Lantech</strong> provides the wireless mesh network solution for seamless roaming beyond traditional WLAN boundaries witheasy deployment.P49


HARDWARE FEATURESIWP-1000b/g IWP-2000-65 IWP-2000-68Data RatesStandards802.11b: 1, 2, 5.5, 11 Mbps802.11g: 6, 9, 12, 18, 24, 36, 48, 54 MbpsIEEE802.11 b/g,IEEE802.1x,IEEE802.3,IEEE802.3u,IEEE802.3af802.11b: 1, 2, 5.5, 11 Mbps802.11g: 6,9,12,18,24,36,48,54 Mbps802.11a: 6,9,12,18,24,36,48,54 MbpsIEEE802.11 a/b/g,IEEE802.1x,IEEE802.3,IEEE802.3u,IEEE802.3af802.11b: 1, 2, 5.5, 11 Mbps802.11g: 6,9,12,18,24,36,48,54 Mbps802.11a: 6,9,12,18,24,36,48,54 MbpsIEEE802.11 a/b/g,IEEE802.1x,IEEE802.3,IEEE802.3u,IEEE802.3afInterface 2* 10/100TX RJ45 (for PoE) 1* 10/100TX RJ45 (for PoE) 1* 10/100TX RJ45 (for PoE)Flash 8M bytes 16M bytes 16M bytesMemory 32MB 64 MB SDRAM 64 MB SDRAMPower RequirementsRF InformationOutput power (± 1.5dBm)Sensitivity(Typical)12~48 VDC on terminal blockwith Reverse Polarity ProtectionIEEE802.11b/g : 20dBm max-81dBm @ 11Mbps, PER< 8%;-64dBm @ 54Mbps, PER< 10%Active Ethernet (Power over Ethernet)48 VDC/0.375AExternal Unit: Auto sensing100/240 VAC; 50/60 Hz802.11a24dBm@6Mps22dBm@36Mps21dBm@48Mps20dBm@54Mps802.11b26dBm@11Mps802.11g26dBm@6~24Mps25dBm@36Mps24dBm@48Mps23dBm@54Mps802.11a-92dBm @ 6Mbps, -72dBm @ 54Mbps802.11b-95dBm @ 1Mbps, -90dBm @ 11Mbps802.11g-92dBm @ 6Mbps, -73dBm @ 54MbpsActive Ethernet (Power over Ethernet)48 VDC/0.375AExternal Unit: Auto sensing100/240 VAC; 50/60 Hz802.11a24dBm@6Mps22dBm@36Mps21dBm@48Mps20dBm@54Mps802.11b26dBm@11Mps802.11g26dBm@6~24Mps25dBm@36Mps24dBm@48Mps23dBm@54Mps802.11a-92dBm @ 6Mbps, -72dBm @ 54Mbps802.11b-95dBm @ 1Mbps, -90dBm @ 11Mbps802.11g-92dBm @ 6Mbps, -73dBm @ 54MbpsOperating Temperature-10°C~55°C-20°C~70°C-30°C~80°C14°F~131°F-4°F~158°F-22°F~175°FStorage Temperature-40°C~85°C-40°C~80°C-40°C~80°C-40°F~185°F-40°F~176°F-40°F~176°FOperating Humidity (Non-condensing) 5%~95% 5%~95% 5%~95%Case DimensionW x D x H (unit=mm)52 x 106 x 144 230 x 230 x 60 230 x 230 x 60Case Protection IP30 IP65 IP68Weight 800g 1200g 3000gDIN Rail Installation ● - -Wall Mount Installation ● - -Pole Mount Installation - ● ●CE/ FCC/ UL CE/ FCC CE/ FCC CE/ FCCRoHS/ WEEE ● ● ●Stability Tests (Free fall/ Shock/ Vibration) ● ● ●MTBF - - -Warranty 5 years 5 years 5 yearsSOFTWARE FEATURESManagementIP Auto-configuration DHCP client/ server DHCP client/ server DHCP client/ serverSNMP V1/ V2 V1/ V2c/ V3 V1/ V2c/ V3NTP server Support NTP client Support NTP client Support NTP clientRemote ConfigurationWeb‐based configuration (HTTP)• Web‐based configuration (HTTP)• Telnet• Web‐based configuration (HTTP)• TelnetMax Client up to 64 users (simultaneously) per radio 32 users (simultaneously) per radio 32 users (simultaneously) per radioNetwork management - <strong>Lantech</strong>-View Pro <strong>Lantech</strong>-View ProOperation ModeAP, Bridge, Repeater, AP-Client, ClientMESH_AP (OLSR), MESH_AP (AODV), AP-Bridge, AP-CB-Bridge, AP-CB- route, CB-CBroute,VLAN-AP , WDS (Repeater)MESH_AP (OLSR), MESH_AP (AODV), AP-Bridge, AP-CB-Bridge, AP-CB- route, CB-CBroute,VLAN-AP , WDS (Repeater)SSID ● Multiple SSID Multiple SSIDSecurity• WEP 64-bit, 128-bit key supported• WPA-WiFi Protected Access• WPA2 (802.11i)• PSK (256-bit key pre-shared key supported)• IEEE802.1x / RADIUS• TKIP encryption• MAC address filtering• IEEE802.1x / RADIUS Client (TTLS, PEAP)Support in AP Mode• IEE802.1x Supplicant (TTLS, PEAP)Support in Client Bridge Mode• WPA-WiFi Protected Access• WPA2 (802.11i)• WEP 64,128 bits• MAC address filtering• Layer2 Isolation• VLAN tunneling Support• Hide SSID• IEEE802.1x / RADIUS Client (TTLS, PEAP)Support in AP Mode• IEE802.1x Supplicant (TTLS, PEAP)Support in Client Bridge Mode• WPA-WiFi Protected Access• WPA2 (802.11i)• WEP 64,128 bits• MAC address filtering• Layer2 Isolation• VLAN tunneling Support• Hide SSIDLLDP ● ● ●AP Scan ● ● ●STP/RSTP ● ● ●QoS - WMM WMMMac Filter Setting 30 Mac Address Setting 15 Mac Address Setting 15 Mac AddressBandwidth limitation -Traffic shaping by IP for each client in Routemode only 30 listTraffic shaping by IP for each client in Routemode only 30 listFirmware Upgrade WEB WEB and TFTP/FTP WEB and TFTP/FTPORDERING INFORMATION (part number)IWP-1000b/g IWP-2000-65 IWP-2000-688310-559 8310-885 8310-888P50


Serial DevicesThe <strong>Lantech</strong> serial device, which is able to convert atleast one serial port (RS232/422/485) to Ethernet orUSB connection, enables user to remotely manage andconfigure device servers via Internet.Serial DevicesIDS-2101F1 RS-232/422/485 portto 1 100FXEthernet Device ServerIDS-21021 RS-232/422/485 portto 2 10/100TXEthernet Device ServerIDS-22044 RS-232/422/485 portto 2 10/100TXEthernet Device ServerDS-ToolLSC-1102Ethernet To RS-232/ 422/ 485Serial Device- With IsolationLSC-0101UUSB To RS-422/ 485Serial Device• Broadcast discovery device• Device server status monitoring• VCOM management• Multi-Wizard function• Device setting functionTechnology Highlights:What is DS-Tool?DS-Tool is Windows-base powerful device server managementsoftware. With its friendly and powerful interface, you can easilyconfigure multiple device servers at the same time, and monitorstatus. DS-Tool contains the following abilities:1. Device discovery2. Auto IP report3. Device setting (run-time change, no rebooting)4. Access control list5. Group setting6. Device monitoring7. Serial port monitoring8. Log info9. Group Firmware update batchP51


HARDWARE FEATURESPortIDS-2101F IDS-2102 IDS-2204 LSC-0101U LSC-1102LAN 1 (100FX) 2 (10/100TX) 2 (10/100TX) - 1 (10/100TX)Serial Ports1 (RS-232/ 422 /485)1 (RS-232/ 422/ 485) 4 (RS-232/ 422 /485)1 (RS-422/ 485)Port 1: RS-232Port 2: RS-232/ 422/ 485USB - - - 1 -LAN Type SC Fiber RJ45 RJ45 - RJ45Serial Type male DB-9, S/W selectable male DB-9, S/W selectable male DB-9, S/W selectable Terminal Block DB-9 + Terminal BlockUSB Type - - -USB type A(Complies to USB 1.0, 1.1, 2.0)-DIP Switch ● ● - ● 9/ 125μmBeeper ● ● ● - -Power 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) USB Bus Power ( 5V ) 9~24VDC, 500mAPower Consumption 4 Watts 4 Watts 5.5 Watts - -Redundant Power ● ● ● - -Overload Current Protection ● ● ● - -Polarity Reverse Protection ● ● ● - -LED ● ● ● ● ●Operating Temperature-20°C~60°C-20°C~60°C-20°C~60°C0°C~60°C-10°C~70°C-4°F~140°F-4°F~140°F-4°F~140°F32°F~140°F14°F~158°FStorage Temperature-40°C~85°C-40°C~85°C-40°C~85°C-20°C~85°C-20°C~85°C-40°F~185°F-40°F~185°F-40°F~185°F-4°F~185°F-4°F~185°FOperating Humidity (Non-condensing) 5%~95% 5%~95% 5%~95% 5%~95% 10%~90%Case DimensionW x D x H (unit=mm)72 x 29.4 x 123.4 72 x 29.4 x 123.4 52 x 106.1 x 144.3 55 x 40 x 29 90 x 60 x 20Case Protection IP30 IP30 IP30 - -Weight 325 g 327 g 678 g 35 g 100 gDIN Rail Installation ● ● ● - ●Wall Mount Installation ● ● ● - ●CE/ FCC/ UL CE/ FCC CE/ FCC CE/ FCC CE/ FCC CE/ FCCRoHS/ WEEE ● ● ● ● ●Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ●MTBF - - 533,615 hours - -Warranty 5 years 5 years 5 years 1 year 1 yearSOFTWARE FEATURESManagementSNMP ● ● ● - -Web ● ● ● - ●DS-Tool ● ● ● - -Telnet ● ● ● - ●ProtocolsSecurityICMP, IP, TCP, UDP, DHCP, BootP,ARP/RARP, Telnet, RTelnet, DNS,SNMP, MIB II, HTP, SMTP, SNTPHTTPS, SSH v2, SSL v3(data encryption)*ICMP, IP, TCP, UDP, DHCP, BootP,ARP/RARP, Telnet, RTelnet, DNS,SNMP, MIB II, HTP, SMTP, SNTPHTTPS, SSH v2, SSL v3(data encryption)*ICMP, IP, TCP, UDP, DHCP, BootP,ARP/RARP, Telnet, DNS, SNMP MIBII, SMTP SNTP-ARP, IP, ICMP, UDP, TCP, HTTP,DHCP, TelnetHTTPS, SSH, SSL (data encryption) - Login PasswordEmail notification ● ● ● - -SNMP Trap ● ● ● - -Serial API FunctionORDERING INFORMATION (part number)Port ControlInput/output DataPort Status InquiryPort ControlInput/output DataPort Status Inquiry- - -IDS-2101F IDS-2102 IDS-2204 LSC-0101U LSC-11028425-001 (MM, 2KM)8425-002 (SM, 30KM)8425-0108425-0208425-0088425-006*OptionalP52


Central Managed Switches<strong>Lantech</strong> business grade managed switches provide fullymanagement functions with Pro-Ring system, whichensures the highest network redundancy. The modularfiber high density switches provide fiber aggregationpoints with flexible configuration.Central Managed SwitchesLES-2400-RPS3 Slots 10/100M Modularized + 2 xGigabit Combo L2 Plus ManagedSwitch w/Redundant Power Supply- Pro-Ring(-20°C~60°C)LGS-2624C20 10/100/1000T + 4 100/1000MSFP Combo + 2 100/1000M SFP L2Plus Managed Switch(-20°C~60°C)Technology Highlights:What is IGMP?LGS-2424C24 10/100/1000T with 4 1000SFPshared cage SNMP Managed Switch( 0°C~45°C)LPGS-2624C20 10/100/1000T + 4 100/1000MSFP Combo + 2 100/1000M SFPPoE + L2 Plus Managed Switch- 802.3 af/at(-20°C~60°C)LGS-2816C-RPS16 100/1000M SFP +8 10/100/1000T/Dual Speed SFPCombo L2 Plus Managed Switchw/Redundant Power Supply(-20°C~60°C)LPES-2224CA24 10/100TX + 2 1000T/SFPcombo with 24 PoE InjectorManaged Switch- 802.3 af( 0°C~45°C)Power Supply100to240 VAC 2YearsWarrantyThe Internet Group ManagementProtocol (IGMP) is acommunications protocol used tomanage the membership ofInternet Protocol multicast groups.IGMP is used by IP hosts andadjacent multicast routers toestablish multicast groupmemberships. IGMP is onlyneeded for IPv4 networks, asmulticast is handled differently inIPv6 networks. IP Multicast is anapplication where needs IGMPQuery and IGMP Snooping. In IPMulticasting network, a Querymode must be enabled firstotherwise the switch would notknow that group members exist.Query mode is usually built in a L3router. <strong>Lantech</strong> Industrial Switch isbuilt-in with IGMP Query andSnooping mode to fill specificneeds, so they are the best to beused in Transportation, FactoryAutomation, Warehouse, TrafficControl, Community Surveillanceapplications.IP TV figureIP TV ViewerIP TV ViewerIP TV ViewerSurveillance figureIP TV ViewerLeaveSwitchSwitchJoinLeaveJoinSwitchSwitchServerMedia MMS ServerIP CameraIP CameraP53


LES-2400-RPS LGS-2424C LGS-2816C-RPS LGS-2624C LPGS-2624C LPES-2224CAHARDWARE FEATURESPort10/100TX Max 24 - - 24 24 24100FX Max 24 - - - - -10/100/1000T - 20 - 20 20 -100M SFP Max 24 - - - -16 (Dual Speed SFP)1000M SFP - - 2 2 -10/100/1000T/1000M SFP Combo 2 4 8 (Dual Speed SFP) 4 4 2RS232 connector DB-9 Female DB-9 Female DB-9 Female RJ-45 RJ-45 DB-9 FemaleSwitching Fabric 8.8Gbps 48Gbps 48Gbps 8.8GbpsPacket Buffer 4Mbits 500Kbytes 1392KB -Jumbo Frame 9K (for Gigabit Ports) 10K 9K 9K (for Gigabit Ports) 9K (for Gigabit Ports) -Mac Address 8K 8K 8K 8K 8K 8KFlash ROM - ROM: 512Kbytes x 2 128M - - -DRAM - RAM: 128Kbytes 512M - - -System Memory - - - - - -Power Supply100~240VAC,50/60Hz100~240VAC,50/60HzRedundant Power 12~48VDC - 12+VDC - - -Power Consumption 18 Watts 17.9 Watts 40 Watts 22.73 Watts 35.78 Watts 20 Watts100~240VAC,50/60Hz100~240VAC,50/60Hz100~240VAC,50/60Hz100~240VAC,50/60HzOperating Temperature-20°C~60°C0°C~45°C-20°C~60°C-20°C~60°C-20°C~60°C0°C~45°C-4°F~140°F32°F~113°F-4°F~140°F-4°F~140°F-4°F~140°F32°F~113°FStorage Temperature-40°C~70°C-40°C~70°C-40°C~70°C- - --40°F~158°F-40°F~158°F-40°F~158°FOperating Humidity (Non-condensing) 5%~95% 10%~95% 5%~90% 10%~90% 10%~90% 10%~90%Case DimensionW x D x H (unit=mm)440 x 280 x 44 440 x 161 x 44 442 x 209 x 44 442 x 170 x 44 442 x 246.5 x 44 440 x 280 x 44Weight 5000g 3200g 2900g - - -19-inch Rack Mount ● ● ● - - -CE/ FCC/ UL ● ● CE/ FCC CE/ FCC CE/ FCC ●RoHS/ WEEE ● ● ● ● ● ●MTBF 75,900 hours 143,964 hours - - - -Warranty 2 years 2 years 2 year 2 years 2 years 2 yearsSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● v1 ● ● ● ●Web Browser ● ● ● ● ● ●Telnet ● ● ● ● ● ●CLI ● ● ● ● ● ●IGMP snooping v1 v2/ IGMP query ● ● ● ● ● ●VLAN ● ● ● ● ● ●Port Trunk with LACP ● ● ● ● ● ●LLDP ● - ● ● ● -Port Security ● - ● ● ● ●IP Security ● ● ● ● ● -Login Security (RADIUS) ● ● ● ● ● ●TACACS+ - - ● ● ● -SNTP ● - NTP ● ● ●SMTP 6 e-mail accounts - 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts -Bandwidth Control ● ● ● ● ● ●Flow Control ● ● ● ● ● ●Pro-Ring SystemX-Ring ● - - - - -Dual Homing ● - - - - -Couple Ring ● - - - - -Spanning Tree/ RSTP STP/ RSTP ● STP/ RSTP/ MSTP STP/ RSTP/MSTP STP/ RSTP/MSTP STP/ RSTPPort Mirror ● ● ● ● ● ●Quality of Service ● ● ● ● ● ●Class of Service ● ● ● ● ● ●System Log ● - ● ● ● ●SNMP Trap ● ● ● ● ● ●DHCP Client/ Server Client Client/ Server Client Client ClientDNS Client/ Server ● - ● - - -TFTP Firmware Update/ Backup /Resotre ● ● ● ● ● ●Configuration upload and download ● ● ● ● ● ●ORDERING INFORMATION (part number)LES-2400-RPS LGS-2424C LGS-2816C-RPS LGS-2624C LPGS-2624C LPES-2224CAStandard model 8220-600 8370-502 8370-900 8370-600 8460-100 8450-1458 100TX Module 8220-510 - - - - -8 100SFP Module 8220-570 - - - - -P54


PoE Series<strong>Lantech</strong> PoE series includes fully-managed switches,splitters and injectors, providing a total PoE solution forour customers. Fully complies with IEEE802.3af/at PoEstandard, <strong>Lantech</strong> PoE series is equipped with IGMPQuery and snooping function for IGMP applicationswhere can release the video network burdenimmediately.PoE SeriesLPES-2208CA8 10/100TX + 2 100/1000 Dual SFPCombo Managed Switch w/8 PoEInjectors- Pro-Ring < 10ms- 802.3 afLPES-2224CA24 10/100TX + 2 1000T/SFP Combow/24 PoE Injector Managed Switch- 802.3 afLPGS-2624C20 10/100/1000T + 4 100/1000MSFP Combo + 2 100/1000M SFPPoE + L2 Plus Managed Switch- 802.3 atPOA-1000ASingle Port POE Power SourceInjector IEEE802.3af/atPoE,10/100/1000Mbps LANPOA-100BSingle Port 802.3af/at PoEPower Source Injector,10/100Mbps LANPOS-100AAdjustable output PowerOver Ethernet Splitter2YearsWarranty1YearWarrantyPoE Splitter and injector, the warranty is one year.Technology Highlights:Port Trunk with LACPPort trunk means to combine separateports together to create a multi-linktrunk with load-balance. LACP stands forLink Aggregation Control Protocol. It is apart of an IEEE specification (802.3ad)that allows administrators to bundleseveral physical ports together to form asingle logical channel. The advantage ofit is to enlarge bandwidth withoptimization.4 ports are a group in which 2 portsare working ports and the othersare standby ports.When link-down happens in workingport, the standby port will becomethe working port.P55


LPES-2208CA LPES-2224CA LPGS-2624C POA-1000A POA-100B POS-100AHARDWARE FEATURESPort10/100TX 8 24 Max 24 1(1000M) 1 110/100/1000T/1000M SFP Combo 2 (Dual Speed SFP) 2 4 - - -RS232 connector DB-9 Female DB-9 Female RJ-45 - - -PoE Injector 8(802.3af) 24(802.3af) 24(802.3af) 1(802.3at/af) 1(802.3at/af) -Switching Fabric 5.6Gbps 8.8Gbps - - -Packet Buffer 1Mbits 3Mbits - - -Mac Address 8K 8K 8K - - -Flash ROM - 512Kbytes x 2 - - - -System Memory - 8Mbytes - - - -100~240VAC, 100~240VAC, 100~240VAC, 100~240VAC, 100~240VAC,Power Input48VDC/0.3A50/60Hz50/60Hz50/60Hz50/60Hz50/60HzPer port feeding Per port feeding Per port feeding5V(2.4A),9V(1.3A),12VPower Outputpower: 15.4Watts power: 15.4Watts power: Up to 30Watts 30W 48VDC, 0.32A 52VDC(1A); Maximum 12W(maximum)(maximum)(maximum)Power Consumption 10 Watts 20 Watts 251.01 Watts 3.6 Watts - -Operating Temperature0°C~45°C0°C to 45°C-20°C~60°C-10°C to 45°C -10°C to 45°C -10°C to 45°C32°F~113°F32°F to 113°F-4°F~140°F14°F to 113°F 14°F to 113°F 14°F to 113°FStorage Temperature-40°C~70°C-40°C~70°C-40°C~70°C- --40°F~158°F-40°F~158°F-40°F~158°FOperating Humidity (Non-condensing) 5%~95% 10%~95% 10%~90% - - 10%~95%Case DimensionW x D x H (unit=mm)217 x 140 x 43 440 x 280 x 44 442 x 246.5 x 44 145 x 60 x 40 145 x 60 x 40 55 x 80 x 31Weight 1632g 3810g - 350g 350g 76gWall Mount Installation ● - - - - -19-inch Rack Mount 10-inch Rack ● - - -CE/ FCC/ UL CE/ FCC ● CE/ FCC ● CE/ FCC CE/ FCCRoHS/ WEEE ● ● ● ● ● ●MTBF 175,813 hours 57,586 hours - - - -Warranty 2 years 2 years 2 years 1 year 1 year 1 yearSOFTWARE FEATURESManagementSNMP v1 v2c v3 ● ● ● - - -Web Browser ● ● ● - - -Telnet ● ● ● - - -CLI ● ● ● - - -IGMP snooping v1 v2/ IGMP query ● ● ● - - -VLAN ● ● ● - - -Port Trunk with LACP ● ● ● - - -LLDP ● - ● - - -Port Security ● ● ● - - -IP Security ● - ● - - -Login Security (RADIUS) ● ● ● - - -SNTP ● ● ● - - -SMTP 6 e-mail accounts - 6 e-mail accounts - - -Bandwidth Control ● ● ● - -Flow Control ● ● ● - -Pro-Ring SystemX-Ring ● - - - - -Dual Homing ● - - - - -Couple Ring ● - - - - -Spanning Tree/ RSTP ● ● STP/ RSTP/MSTP - - -Port Mirror ● ● ● - - -Quality of Service ● - ● - - -Class of Service ● ● ● - - -System Log ● ● ● - - -SNMP Trap ● ● ● - - -DHCP Client/ Server Client Client - - -DNS Client/ Server ● - - - - -TFTP Firmware Update/ Backup /Resotre ● ● ● - - -Configuration upload and download ● - ● - - -ORDERING INFORMATION (part number)LPES-2208CA LPES-2224CA LPGS-2624C POA-1000A POA-100B POS-100AStandard model 8450-540 8450-145 8461-100 8450-360 8450-353 8450-220P56


Fiber Converters<strong>Lantech</strong> converter series provides the flexibility for theusers to covert network connection between fiber portand RJ-45 port. The Multi-Converter Chassis for 10converters is also available, which providesplug-and-play and hot-swappable features.Fiber ConvertersCM-011 FiberWith SC connectorMulti/Single-modeMulti-Converter Chassis10 slots Converter ChassisCM-011 FiberWith ST connectorMulti/Single-modeCM-011 FiberWith WDM connectorSingle-modeCM-011 DIP-Switch SettingCM-021-GB-II10/100/1000BaseTto Gigabit FiberMedia Converter-Jumbo Frame 9K1 UTP Auto-Nego / 100Mbps Full Duplex mode2 Fiber Full/Half Duplex3 LLF (Link Lose Forwarding) Disable/Enable4 Switch Converter / Pure converter modeCM-021 DIP-Switch Setting1 LLF Enable / LLF Disable2 Pure converter mode / Switch converter mode3 Reserved / Reserved0°Cto+45°CPower Supply9 VDC2YearsWarrantyTechnology Highlights:What is Multi-Converter Chassis?<strong>Lantech</strong> Multi-Converter Chassis providesnot only 10 independent converter slots,but also one optional extra redundantpower supply. There are various modulesto satisfy the demand of users, whichinclude Fiber converter series (with LLFfunction) and Gigabit converter series. Allthe converters and redundant powersupply supports plug-and-play andhot-swappable features which allow userto plug or pull out the converters/redundant power supply withoutrebooting the chassis.Power budget = Output power - SensitivityItem MMF SMFCore Diameter 50 or 62.5 um 9 umBandwidth 10G Un - limitedDistance 100M 2km 20 - 120km1Gbps500m (50 um)275m (62.5 um)CWDM / DWDM N/A YESAttenuation :1310nm : 0.4dB -0.45dB / km1550nm : 0.2dB -0.25dB / km10 - 120kmLaser FP Laser FP(


CM-011-ST-MM CM-011-SC-MM CM-011-SC-MM-5KM CM-011-SC-SM-60KM CM-011-SC-SM-30KM CM-011-WDM13 CM-011-WDM15 CM-021-GB-IIHARDWARE FEATURESPort10/100TX 1 1 1 1 1 1 1 -100FX ST, Multi-mode x 1 SC, Multi-mode x 1 SC, Multi-mode x 1 SC, Single-mode x 1 SC, Single-mode x 1 LC, Tx 1310nm, WDM x 1 LC, Tx 1550nm, WDM x 1 -10/100/1000T - - - - - - - 11000M SFP - - - - - - - 1Jumbo Frame - - - - - - - 9KbytesPower Supply DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7APower Consumption 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.8 WattsOperating Temperature0°C~45°C0°C~45°C0°C~45°C0°C~45°C0°C~45°C0°C~45°C0°C~45°C0°C to 45°C32°F~113°F32°F~113°F32°F~113°F32°F~113°F32°F~113°F32°F~113°F32°F~113°F32°F to 113°FStorage Temperature-40°C~70°C-40°C~70°C-40°C~70°C-40°C~70°C-40°C~70°C-40°C~70°C-40°C~70°C-40°C~70°C-40°F~158°F-40°F~158°F-40°F~158°F-40°F~158°F-40°F~158°F-40°F~158°F-40°F~158°F-40°F~158°FOperating Humidity (Non-condensing) 10%~95% 10%~95% 10%~95% 10%~95% 10%~95% 10%~95% 10%~95% 10%~95%Case DimensionW x D x H (unit=mm)119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26Weight 740g 740g 740g 740g 740g 740g 740g 754g19-inch Rack Mount ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with ChassisCE/ FCC/ UL ● ● ● ● ● ● ● ●RoHS/ WEEE ● ● ● ● ● ● ● ●MTBF 111,076 hours 111,076 hours 111,076 hours 111,076 hours 111,076 hours 111,076 hours 111,076 hours 443,282 hoursWarranty 2 years 2 years 2 years 2 years 2 years 2 years 2 years 2 yearsORDERING INFORMATION (part number)CM-011-ST-MM CM-011-SC-MM CM-011-SC-MM-5KM CM-011-SC-SM-60KM CM-011-SC-SM-30KM CM-011-WDM13 CM-011-WDM15 CM-021-GB-II8421-150 8421-151 8421-155 8421-170 8421-171 8421-180 8421-1818421-232Mini-GBICSpecifically designed for the high performance integrated data link, <strong>Lantech</strong> miniGBIC series provides avariety of Small Form Factor Pluggable (SFP) transceiver modules. The series covers 1.25Gbps/ 125Mbps forthe distance from 100m to 120km with long MTBF, which ensures the durability.SFP 125MbpsPart Number Wavelength LD IO LOS Mode Link Temp.8330-060 1310nm FP AC/AC TTL Multi-mode 2km -10~70°C8330-065 1310nm FP AC/AC TTL Multi-mode 5km -10~70°C8330-061 1310nm FP AC/AC TTL Single-mode 30km -10~70°CSFP 1.25GbpsPart Number Wavelength LD IO LOS Mode Link Temp.8330-162 850 nm VCSEL 550m -10~70°CMulti-mode8330-163 1310 nm FP 2km -10~70°C8330-165 1310 nm FP 10km -10~70°C8340-0591 1310 nm DFB 40km -10~70°CAC/ACTTL8330-166 1550 nm DFB 50km -10~70°CSingle-mode8330-169 1550 nm DFB 60km -10~70°C8330-167 1550 nm DFB 80km -10~70°C8330-170 1550 nm DFB 120km -10~70°CSFP 1000TPart Number8330-1688330-168-EDescription10/100/1000Base-T, SFP, 100m, 3.3V, -10~70°C10/100/1000Base-T, SFP, 100m, 3.3V, -40~85°CBiDi SFP 1.25Gbps/125MbpsPart Number TX LD RX IO LOS Link Temp.8330-069 FP 20km8330-080 FP 40km8330-188 FP 10km1310nm8330-186 FP 20km8330-180 DFB 40km8330-181 DFB 60km1550nm8330-184 1490nm DFB 80km8330-188-E FP 10km8330-186-E FP 20km1310nm8330-180-E DFB 40km8330-181-E DFB 60km8330-184-E 1490nm DFB 80kmAC/ACTTL8330-068 20km8330-086 40km8330-189 10km1310nm8330-187 20km8330-182 40km8330-183 60km8330-1851550nmDFB1490nm 80km8330-189-E8330-187-E8330-182-E8330-183-E1310nm8330-185-E 1490nm 80km125Mbps/1.25Gbps Dual-ratePart Number Wavelength LD IO LOS Mode Link Temp.8330-191 1310nm FP AC/AC TTL Single-mode 10km -10~70°C8330-191-E 1310nm FP AC/AC TTL Single-mode 10km -40~85°C10km20km40km60km-10~70°C-40~85°C-10~70°C-40~85°C1YearWarrantyTechnology Highlights:What is DDM?DDM(Digital Diagnostic Monitoring) MSAfunction are provided with voltage,temperature, TX power, RX power andlaser bias current over the network.DDM function enables central site toremote monitor each fiber link qualitywith ease.P58


Power and Accessories<strong>Lantech</strong> power with DIN Rail series is rigid and compactfor space saving and industrial applications. It supportspower ready signal and ring diode circuit for redundantapplication as well as over-voltage, over-load and shortcircuit protection. The series provides various modelswhich cover different output voltages and currents.Power and AccessoriesAD1024F24Watts,Single Output Powerwith DIN RailDIN Rail PowerModelO/P voltageAdjustmentAD1048-24F(S)48Watts,Single Output Powerwith DIN RailAD1120F120Watts,Dual Output Powerwith DIN RailLoading (A)RippleOvervoltageLine Reg. Load Reg. EfficiencyMin. Rated Max. Noise ProtectionAD1024-24F +24VDC±10% 0A 1A 1A 150mVp-p ±1% ±1% 83% 40VDC MaxAD1024-24F-E +24VDC±10% 0A 1A 1A 150mVp-p ±1% ±1% 83% 40VDC MaxAD1024-48F +48VDC±10% 0A 0.5A 0.5A 250mVp-p ±1% ±1% 83% 60VDC MaxAD1048-24FS +24VDC±10% 0A 2A 2A 150mVp-p ±1% ±1% 83% 40VDC MaxAD1048-24FS-E +24VDC±10% 0A 2A 2A 150mVp-p ±1% ±1% 83% 40VDC MaxAD1048-48FS +48VDC±10% 0A 1A 1A 250mVp-p ±1% ±1% 83% 60VDC MaxAD1120-24F +24VDC±10% 0A 5A 5A 150mVp-p ±1% ±1% 81% 27~30VDC MaxAD1120-48F +48VDC±10% 0A 2.5A 2.5A 550mVp-p ±1% ±1% 83% 52~56VDC MaxAD1240-24S +24VDC±10% 0A 10A 10A 150mVp-p ±1% ±1% 83% 27~30VDCAD1240-48S +48VDC±10% 0A 5A 5A 250mVp-p ±1% ±1% 84% 52~56VDCEach output can supply maximum current, but loading cannot exceed rated output wattage.Note: 1. up to total2. Line regulation is measured from low line to high line at rated load.3. Load regulation is measured from 20% to 100% of rated load at 110VAC input.4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic capacitor parallel on the test point, at rated load and 110VAC input.5. Efficiency is measured at rated load and 110VAC input.AD1240S240Watts,Dual Output Powerwith DIN Rail1YearWarrantyM12 Connector / CablePart NumberDescriptionECON120005MM 5 Pin M12 Power Male ConnectorECON120004FF4 Pin M12 RJ45 Female ConnectorECON120003FF3 Pin M12 Relay Female ConnectorConnectorPowerECAB125030F0ECAB123030M05 Pin M12 Power Female 3M Cable3 Pin M12 Relay Male 3M CableECAB124030MJ4 Pin M12 RJ45 Male 3M CableECAB124030MM 4 Pin M12 Male-Male 3M CableP-FailConsoleM12 ConnectorM12 Cable1YearWarrantyBracketPart NumberMBAK19001MBAK19002MBAK003085Description19” Rack Mounting Kit for 72x105x152mm Industrial SwitchL-Bracket that can change 90 degree of DIN rail mounting19” Rack Mounting Ear for 217x141x66mm Industrial Switch19 inch BracketL BracketP59


NoteNoteP60

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!