13.07.2015 Views

KCD2-RR-Ex1 Thermometer Resistance Repeater Barrier

KCD2-RR-Ex1 Thermometer Resistance Repeater Barrier

KCD2-RR-Ex1 Thermometer Resistance Repeater Barrier

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical data<strong>KCD2</strong>-<strong>RR</strong>-<strong>Ex1</strong>Release date 2010-11-22 14:41 Date of issue 2011-04-04 190247_ENG.xmlGeneral specificationsSignal typeSupplyAnalog inputConnection Power Rail or terminals 9+, 10-Rated voltage19 ... 30 V DCRipplewithin the supply toleranceRated current< 20 mAPower consumption0.35 W (24 V and 1 mA sense current)InputConnection terminals 1, 2, 3, 4Line fault detectionyes , at Pt100Lead resistance≤ 10 % of resistance valueTransmission range0 ... 10 mAAvailable voltage9 VLead monitoring50 nAOutputConnection terminals 5-, 7-, 6+, 8+Current0 ... 10 mAAvailable voltage0 ... 7 VFault signal< 10 Ω or > 400 Ω, depending on lead disconnected (measuring current ≤ 1mA)Transfer characteristicsDeviationI m ≥ 1 mA: ± 0.1 % of R m or ± 0.1 Ω (the larger value is applicable)I m < 1 mA: accuracy reduces in proportion to I m .e. g. I m = 0.1 mA: ± 1 % of R m or 1 Ω (the larger value is applicable).Influence of ambient temperature I m ≥ 1 mA, R m ≥ 100 Ω : 0.01 %/K in the range -20 ... +60 °C (253 ... 333 K)I m < 1 mA or R m < 100 Ω: temperature stability reduces in proportion to I m or R mRise time signal response time ≤ 2 ms (10 ... 90 %)response to application of I m : R m > 50 Ω and I m < 5mA: < 5msresponse to application of I m : R m > 30 Ω and I m < 5mA: < 10msresponse to application of I m : R m > 18 Ω and I m < 5mA: < 20msElectrical isolationOutput/power supplyDirective conformityElectromagnetic compatibilityfunctional insulation, rated insulation voltage 50 V ACDirective 2004/108/EC EN 61326-1:2006ConformityElectromagnetic compatibility NE 21Protection degree IEC 60529Protection against electric shock UL 61010-1Ambient conditionsAmbient temperature-20 ... 60 °C (-4 ... 140 °F)Mechanical specificationsProtection degreeIP20Massapprox. 100 gDimensions12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 in) , housing type A2Data for application in connectionwith Ex-areasEC-Type Examination Certificate BASEEFA 10 ATEX 0061 , for additional certificates see www.pepperl-fuchs.comGroup, category, type of protection ¬ II (1)GD, I (M1), [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ T amb ≤ 60 °C) [circuit(s) in zone 0/1/2]Voltage U o 12.4 VCurrent I o 17.4 mAPower P o 54 mWSupplyMaximum safe voltage U m253 V (Attention! The rated voltage can be lower.)Type of protection [EEx ia]OutputMaximum safe voltage U m253 V (Attention! The rated voltage can be lower.)Statement of conformityBASEEFA 10 ATEX 0062X , observe statement of conformityGroup, category, type of protection, ¬ II 3G Ex nA II T4temperature classificationElectrical isolationInput/Outputsafe electrical isolation acc. to IEC 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC 60079-11, voltage peak value 375 VDirective conformityDirective 94/9/EC EN 60079-0:2006, EN 60079-11:2007, EN 60079-15:2005, EN 61241-11:2006International approvalsSubject to reasonable modifications due to technical advances.Copyright Pepperl+Fuchs, Printed in GermanyPepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!