13.07.2015 Views

User Manual - ALLSEASONS Heating And Cooling

User Manual - ALLSEASONS Heating And Cooling

User Manual - ALLSEASONS Heating And Cooling

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5GENERAL INSTRUCTIONSTHIS GAS STOVE SHOULD BE INSTALLED AND SERVICEDBY A QUALIFIED INSTALLER to conform with local codes. Installationpractices vary from region to region and it is important toknow the specifics that apply to your area,for example: in Massachusetts State:• The fireplace damper must be removed or welded in the openposition prior to installation of a fireplace insert or gas log.• The appliance off valve must be a “T” handle gas cock.• The flexible connector must not be longer than 36 inches.• The appliance is not approved for installation in a bedroom orbathroom unless the unit is a direct vent sealed combustionproduct.• WARNING: This product must be installed by a licensed plumberor gas fitter when installed within the commonwealth ofMassachusetts.In absence of local codes, install to the current CAN1-B149Installation Code in Canada or to the National Fuel Gas Code,ANSI Z223.1, and NFPA 54 in the United States. Mobile homeinstallation must conform with local codes. In the absence oflocal codes, install to the current standard for gas equippedmobile housing CAN/CSA Z240 MH Series in Canada or themanufactured home construction and safety standard, Title 24CFR, part 3280, or the Fire Safety Criteria for manufacturedhome installations, Sites and Community Standard ANSI/NFPA501A in the United States.Purge all gas lines with the glass door of the stove removed.Assure that a continuous gas flow is at the burner before reinstallingthe door.Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition.It is recommended that all horizontal runs have a ¼ inch riseper foot.Objects placed in front of the stove must be kept a minimumof 48" away from the front face of the unit.The stove and its individual shutoff valve must be disconnectedfrom the gas supply piping system during any pressure testing ofthat system at test pressures in excess of 1/2 psig (3.5 kPa). Thestove must be isolated from the gas supply piping system byclosing its individual manual shutoff valve during any pressuretesting of the gas supply piping system at test pressures equal toor less than ½ psig (3.5 kPa).The stove, when installed with a blower, must be electrically connectedand grounded in accordance with local codes. In the absenceof local codes, use the current CSA C22.1 CANADIANELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONALELECTRICAL CODE in the United States. The blower power cordmust be connected into a properly grounded receptacle. Thegrounding prong must not be removed from the cord plug.Expansion / contraction noises during heating up and coolingdown cycles are normal and to be expected.This appliance is only for use with the type of gas indicatedon the rating plate. This appliance is not convertible for usewith other gases, unless a certified kit is used.CARE OF GLASS, AND PLATED PARTSDo not use abrasive cleaners to clean these parts. Bufflightly with a clean dry cloth.The glass is 3 / 16" ceramic glass available from your Napoleon/ Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATE-RIALS. Clean the glass after the first 10 hours of operationwith a recommended gas fireplace glass cleaner. Thereafterclean as required. DO NOT CLEAN GLASS WHEN HOT!If the glass is not kept clean permanent discolouration and/ or blemishes may result.GDS20: Maximum input is 20,000 BTU/hr for natural gasand propane. Maximum output for natural gas and propaneis 15,600 BTU/hr at an efficiency of 78%.This stove is approved for closet or recessed installations,as well as for bathroom, bedroom and bed-sitting roominstallations and is suitable for mobile home installations.The natural gas model can be installed in a mobile homethat is permanently positioned on its site and fueled withnatural gas.GENERAL INFORMATIONFOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!Minimum inlet gas supply pressure is 4.5 inches water column fornatural gas and 11 inches water column for propane. Maximuminlet gas pressure is 7 inches water column for natural gas and 13inches water column for propane. When the valve is set to "HI", themanifold pressure under flow conditions is 3.5 inches water columnfor natural gas and 10 inches water column for propane.When the fireplace is installed at elevations above 4,500ft, and inthe absence of specific recommendations from the local authorityhaving jurisdiction, the certified high altitude input rating shall bereduced at the rate of 4% for each additional 1,000ft.W415-0496 / B / 08.10.05

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!