VENTING LENGTHS &AIR TERMINAL LOCATIONSUse only Wolf Steel, Simpson Dura-Vent, Selkirk DirectTemp or American Metal Amerivent venting components.For Simpson Dura-Vent, Selkirk Direct Temp and AmericanMetal Amerivent, follow the installation procedure providedwith the venting components.All outer pipe joints of these venting systems must besealed using Red RTV High Temperature Sealant.Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp andAmerican Metal Amerivent venting systems must not becombined.A starter adaptor must be used and may be purchasedfrom the corresponding supplier:Supplier GAS STOVEDuravent GDS924NAmerivent 4DSCB-N1Direct Temp 4DT-AANFor vent systems that provide seals on the inner exhaustflue, only the outer air intake joints must be sealed using ared high temperature silicone (RTV). This same sealantmaybe used on both the inner exhaust and outer intakevent pipe joints of all other approved vent systems exceptfor the exhaust vent pipe connection to the fireplace fluecollar which must be sealed using the black high temperaturesealant Mill Pac. High temperature sealant must beordered separately.When using Wolf Steel venting components, use only thefollowing vent kits: WALL TERMINAL KIT GD175 (7-1/2' ofventing included), WALL TERMINAL KIT GD176 (24" of ventingincluded), or 1/12 TO 7/12 PITCH ROOF TERMINAL KITGD110, 8/12 TO 12/12 ROOF TERMINAL KIT GD111, FLATROOF TERMINAL KIT GD112 or STOVE PERISCOPE KITGD180 (for wall penetration below grade) in conjunctionwith the appropriate venting components.For optimum performance, it is recommendedthat all horizontal runs have aminimum ¼ inch rise per foot.VENTINGHORIZONTAL RUN NOT TOEXCEED VERTICAL RISEFIGURE 5FIGS 6a-b9• For optimum flame appearance and stove performance,keep the vent length and number of elbows to a minimum.• The air terminal must remain unobstructed at all times.Examine the air terminal at least once a year to verify thatit is unobstructed and undamaged.The maximum horizontal run with a 57 inch vertical riseimmediately above the stove is 20 feet . FIGURES 6a-b.• These vent kits allow foreither horizontal or verticalventing of the stove.• The maximum number of4" flexible connectionsis 3 horizontally or threevertically (excluding thestove and the air terminalconnections).• When terminatingvertically, the minimumvertical rise is 3 feetabove the stove and theFIGURE 4maximum vertical rise is40 feet. FIGURE 4.Deviation from the minimum vertical vent length cancreate difficulty in burner start-up and/or carboning.Use an adjustable pipe as the final length of rigid pipingto the stove for ease of installation.W415-0496 / B / 08.10.05

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!