17.07.2015 Views

LEGACY Control System operations - Lionel

LEGACY Control System operations - Lionel

LEGACY Control System operations - Lionel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Conventional transformer <strong>operations</strong>Using the <strong>LEGACY</strong> RailSounds sound system in the conventional environmentWhen you first power up your locomotive, you will hear the sounds of the locomotiveat rest. As the locomotive set moves, the RPM sounds automatically increase withthe locomotive’s speed. In the conventional environment, the horn and bell sounds areactivated by your transformer controls.To silence the motor sounds, slide the <strong>LEGACY</strong> RailSounds sound system switch locatedunder the drop down door below the cab to the BELL HORN position (see Figure 2 on page10 for the location of this switch) before you power up the locomotive or after the locomotivehas been powered down for a minimum of ten seconds. The horn and bell sounds will still beactive. To adjust the volume, use the volume control knob located under the drop down doorbelow the cab. Refer to Figure 2 on page 10.Note!Note!When the <strong>LEGACY</strong> RailSounds sounds system switch is in the “BELL HORN”position, the CrewTalk dialog and TowerCom announcements are inactive.For proper operation of the <strong>LEGACY</strong> RailSounds sound system during trackpower interruptions and for the locomotive shutdown sequence, you mustinstall a nine-volt alkaline battery. Refer to Figure 3 on page 11.In the conventional environment, you will experience several features of the <strong>LEGACY</strong>RailSounds sound system.• Eight levels of diesel motor RPM. The level of diesel motor RPM automaticallyvaries with your throttle adjustments.• MultiHorn. A different horn sound at different speeds—a <strong>LEGACY</strong> RailSoundssound system exclusive.• Mechanical bell. Press BELL on your transformer to begin the effect, then pressBELL a second time to discontinue the effect.• CrewTalk dialog and TowerCom announcements. CrewTalk dialog is triggered byyour transformer’s HORN button. See page 31.• Reverse unit reset sound. Power down your track, wait three seconds, andlisten for the air-release sound—that’s the locomotive telling you that its <strong>Lionel</strong>Command reverse unit has reset to forward. Because the track is powered down, anine-volt alkaline battery is required for this feature. Refer to Figure 3 on page 11.• Shutdown sequence. When you turn off track power, you have two seconds to powerup again after you hear the reverse unit reset sound. If you do not restore power,you will hear the realistic diesel shutdown sequence. Because track power is off,a nine-volt battery is required for this sequence to function. Refer to Figure 3 onpage 11.30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!