30.07.2015 Views

BM31 - BEKO TECHNOLOGIES GmbH

BM31 - BEKO TECHNOLOGIES GmbH

BM31 - BEKO TECHNOLOGIES GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Pos: 45 /Beko T echnische D okumentati on/Sicher hei t/Gefahr Netzspannung @ 0\mod_1184148186948_15098.doc @ 15122 @ @ 1Pos: 46 /Beko T echnische D okumentati on/Sicher hei t/Maßnahmen N etzspannung BM 31/32/33 @ 0\mod_1216898430699_15098.doc @ 15250 @ @ 1Pos: 47 /Beko T echnische D okumentati on/Installati on/<strong>BEKO</strong>MAT /El ektrInstallation Hi nweise <strong>BM31</strong> allg. @ 0\mod_1184228454108_15098.doc @ 15129 @ 1 @ 1Pos: 48 /Beko T echnische D okumentati on/Installati on/<strong>BEKO</strong>MAT /Kl emmenbel egung BM 31 @ 0\mod_1184249465135_15098.doc @ 15130 @ @ 1Electrical installationPos: 44 /Beko T echnische D okumentati on/Überschriften/1/Elektrische Install ati on @ 0\mod_1183638507355_15098.doc @ 15116 @ 1 @ 19 Electrical installationMeasures:Danger!Supply voltage!There is the risk of an electric shock involving injury or death when coming into contactwith non-insulated components carrying supply voltage.• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100/ IEC 60364).• Service measures must only be undertaken when the system is deactivated.• The removed control unit has no IP degree of protection.• All types of electrical works must be carried out by authorized and qualified personnel only.Note:1. Read the permissible mains voltage on the type plateand make sure this voltage is observed.2. At an AC supply, a reliably accessible separator mustbe provided close-by (e.g. power plug or switch),which separates all current-carrying conductors.3. At a DC supply, only use a protective extra-lowvoltage(PELV) in accordance with IEC 60364-4-41.4. Carry out installation in accordance with VDE 0100 /IEC 60364.5. Observe the terminal assignment.6. Do not install when the device is energised.7. Unscrew the screw (1) and remove the upper part ofthe cover (2).8. Unscrew the threaded cable connection (3), removethe plug (if there is one) and lead the cable (4) for thesupply voltage through.9. Connect the cable (4) with terminals KL1 (1.1 ... 1.3)(5).10.Install the cables as shown (see also terminal assignment).11.Tighten the threaded cable connection (3) with aslightly sealing effect.12.Put on the upper part of the cover (2) and tighten thescrew (1) fingertight.13.Between the earth conductor/PE connection and thepiping, a potential difference is not admissible. If required,potential equalisation in accordance with IEC60364 / VDE 0100 must be provided for.<strong>BEKO</strong>MAT® 31 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!