Centrifugal <strong>Fans</strong><br />

▲ <strong>for</strong> <strong>Power</strong> <strong>Plants</strong><br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong>


Radialfans<br />

<strong>for</strong> <strong>Power</strong> <strong>Plants</strong><br />

Engineering and progress in air technology<br />

The requirements imposed on Industrial <strong>Fans</strong> have noticeably<br />

increased over the years.<br />

The variety of problems that need to be tackled when handling<br />

gases requires a comprehensive range of fans to optimize<br />

the selection <strong>for</strong> each particular application.<br />

Decades of intensive research and operating experience<br />

gained during this time are the basis <strong>for</strong> our fan range that<br />

provides the best economical choice <strong>for</strong> any application.<br />

Guiding factors <strong>for</strong> the development of this range have<br />

been:<br />

• Low Investment Cost<br />

• Low Operating Cost<br />

• High Reliability<br />

• Long Life<br />

• High Noise Attenuation<br />

Werner Glöckner,<br />

Division Manager - Industrial fans<br />

At the beginning of 2003, <strong>TLT</strong> was taken over by<br />

AG Kühnle, Kopp und Kausch, and since has<br />

been trading under the name of <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

as an independent company within the group.<br />

The affiliation with the KK&K Group gives us the<br />

opportunity to even better use the big development<br />

potential in the field of air technology engineering.<br />

Together we are strong.


Since more than<br />

130 years ...<br />

<strong>TLT</strong> workshop<br />

in Bad Hersfeld


fans from Bad Hersfeld<br />

Tradition and development.<br />

In 1874, when Benno Schilde and August Büttner<br />

started their own enterprises independently from<br />

each other, neither of them anticipated that more<br />

than 130 years later there would be in Bad<br />

Hersfeld one of the most modern manufacturing<br />

places.<br />

They started with " Exhausters”, first mainly made<br />

out of Cast Iron. Later steel plates were used,<br />

reducing weight and costs. Our engineers moved<br />

on and developed fans of highest quality and<br />

most reliable technology.<br />

Based on this tradition, a most successful company<br />

developed with highly innovative products.<br />

For nearly all industrial applications our fans are<br />

used in various designs.<br />

Today, <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong> offers a complete programme<br />

<strong>for</strong> the different industries.<br />

Heike Blum,<br />

Secretary


Abnahmeprüfung<br />

Quality production


Safe, reliable and economical<br />

With few exceptions, the large variety of available fan types nearly<br />

always permits direct coupling of the fan to the drive motor. We<br />

prefer this arrangement because system reliability is optimizied by<br />

avoiding interconnecting equipment such as gear boxes, belt drives,<br />

etc.<br />

The basic design flexibility of our fans permitting alterations to or<br />

replacement of the impeller enables us to match actual operating<br />

conditions if it is found during operation that they differ from the<br />

conditions on which the original design data are based.<br />

Furthermore, blade tip adjustment on centrifugal fan wheels is in<br />

many cases, a simple mean to meet specific operating conditions.<br />

from start to finish


Quality assurance: We<br />

Tested safety<br />

Our quality assurance system guarantees perfect products on a<br />

constantly high level – in material, workmanship, technology and<br />

function as well as in user and operating safety.<br />

Quality of a product is determined in its development phase<br />

already. For this reason, our quality assurance starts no later than<br />

at this stage.<br />

The fan range of <strong>TLT</strong> includes:<br />

Single or multi stage centrifugal fans<br />

with maximum efficiency at pressures<br />

up to 50.000 Pa. Standart and heavy<br />

duty designs are available.<br />

Double width double inlet centrifugal<br />

fans <strong>for</strong> large flow volume. Standart<br />

and heavy duty designs are available.<br />

Centrifugal fan, rotor supported on<br />

both sides, fan supportded by an integral<br />

steel frame.


set standards<br />

Our staff consider quality as a decisive element in their daily work.<br />

It belongs to their most important tasks to continuously check our<br />

quality assurance system and to update it, if and when necessary.<br />

Thus, its effectiveness is ensured permanently.<br />

Our quality management in compliance with DIN ISO EN<br />

9001 ensures that all materials we process, manufactured<br />

components, assemblies, individual products and complete<br />

system meet the high requirements.<br />

We obriously adhire to national and international standards<br />

and laws as well as to all contractual regulations.<br />

Thomas Koch,<br />

Head of design departement


Impeller with airfoild<br />

Impeller with airfoiled blades <strong>for</strong> I.D, PA and FD-<strong>Fans</strong>.<br />

High effiency (up to 90%) will reduce operating costs to a minimum level.<br />

Airfolied blades inside rein<strong>for</strong>ced<br />

Impeller, during balancing in the <strong>TLT</strong>-<strong>Turbo</strong> workshop, <strong>for</strong> an I.D. Fan in a<br />

power plant in Taichung (Taiwan).<br />

Technical Datas:<br />

Volume flow: 518,9 m 3 /s<br />

Total pressure increase: 10415 Pa<br />

Temperature: 160°C<br />

Speed: 890 rpm<br />

Shaft power: 5792 kW<br />

Efficiency: 90 %<br />

Impeller diameter: 3550 mm<br />

Tip speed: 165 m/s<br />

Year of delivery: 2002<br />

Control: with inlet vane control


lades…<br />

Impeller with airfoiled blades <strong>for</strong> I.D., PA and FD <strong>Fans</strong><br />

Volume flow up to 800 m 3 /s<br />

Pressure increase up to 15000Pa<br />

Shaft power up to 7000 kW<br />

Casing <strong>for</strong> a PA fan <strong>for</strong> a power plant in Iskenderun (Turkey).<br />

Technical Datas:<br />

Volume flow: 115 m 3 /s<br />

total pressure increase: 19766 Pa<br />

Shaft power: 1858 kW<br />

Efficiency: 87,1%<br />

impeller diameter: 2066 mm<br />

Tip speed: 161 m/s<br />

Year of delivery: 2003<br />

<strong>for</strong> <strong>Power</strong> <strong>Plants</strong>


<strong>Booster</strong> Fan<br />

<strong>Booster</strong> <strong>Fans</strong> <strong>for</strong><br />

<strong>Power</strong> <strong>Plants</strong><br />

<strong>Booster</strong> fan <strong>for</strong> a power plant in Yeniköy (Turkey)<br />

Technical Datas:<br />

Volume flow: 755,1 m 3 /s<br />

Total pressure increase: 3377 Pa<br />

Temperature: 153°C<br />

Shaft power: 2866 kW<br />

Efficiency: 88%<br />

Speed: 495 rpm<br />

Impeler diameters: 4160 mm<br />

Tip speed: 108 m/s<br />

Year of delivery: 2000<br />

Control: inlet vane controll,<br />

IVC located inside the housing<br />

This is the fan with the highest volume flow, <strong>TLT</strong>-<strong>Turbo</strong><br />

have manufactured as a centrifugal fan.<br />

Ralf Schreiber,<br />

Sales Engineer


Stainless steel application<br />

Rotor <strong>for</strong> a booster Fan <strong>for</strong> a FGD Plant in<br />

Brindisi (Italy) <strong>for</strong> corrosive medium (SO 2)<br />

Impeller in stainless steel (1.4565) =<br />

X2CRNIMnMoN25-18-6-5<br />

shaft rubber lined<br />

Technical Datas:<br />

Volume flow: 563 m 3 /s<br />

Pressure increase: 8155 Pa<br />

Shaft power: 5054 kW<br />

Efficiency: 88,3%<br />

Impeller diameter: 4050 mm<br />

Tip speed: 123 m/s<br />

Year of delivery: 2004<br />

Drilling the<br />

impeller hub<br />

Stainless<br />

Steel Rotor<br />

Stain


less Steel Application


Impeller with single t<br />

Impeller with single thickness blades <strong>for</strong> pressure increases up to 30000 Pa<br />

(single stage). For pressure increases up to 50000 Pa (double stage).<br />

We built single-stage radial flow-fans <strong>for</strong> a specific energy of<br />

more than 40000 J/kg. It depends on the case of need, temperature,<br />

volume/pressure ratio and the possible speed from what<br />

pressure increase the fan has to be of the double-stage type.<br />

Mill Fan <strong>for</strong> a power plant in Voerck (Germany)


hickness blades<br />

straight blades<br />

inlet angle: 60°<br />

outlet angle: 78°<br />

application <strong>for</strong> adhasive dust<br />

impeller backward curved, high pressure increase at high<br />

efficiency.<br />

inlet angle: 35°<br />

outlet angle: from 40-45°<br />

<strong>for</strong>warded curved blade<br />

inlet angle: 40°<br />

outlet angle: 90°<br />

application <strong>for</strong> wet dust<br />

Curved backward inclined blade profile <strong>for</strong> dust application<br />

which optimizes efficiency and minimizes build up.<br />

Most of the dust passes through the impeller without getting<br />

trapped and without creating major build up.<br />

inlet angle: 45°<br />

outlet angle: 45°


Per<strong>for</strong>mance Test in t<br />

Per<strong>for</strong>mance test <strong>for</strong> an I.D. Fan and a F.D. Fan, with reduced speed, driven by diesel<br />

engine, in the <strong>TLT</strong>-<strong>Turbo</strong> workshop. <strong>TLT</strong>-<strong>Turbo</strong> delivered 4 I.D. <strong>Fans</strong>, 4 F.D <strong>Fans</strong> and 4<br />

P.A <strong>Fans</strong> <strong>for</strong> the SSAA <strong>Power</strong> Station 3 in Malysia in 1996.<br />

Technical datas F.D Fan type 14144ZA1920<br />

Volume flow: 304,3 m 3 /s<br />

Pressure increase: 4454 Pa<br />

Inlet temperature: 40°C<br />

Shaft power: 1509 kW<br />

Control: combined hydraulic coupling and IVC<br />

(ICC located inside fan housing)<br />

Impeller blade shape: airfoiled<br />

Efficiency: 88,1%


e <strong>TLT</strong> workshop<br />

Technical Datas I.D. Fan Type 14144ZA2282<br />

Volume Flow: 432 m_/s<br />

Pressure increase: 4941 Pa<br />

inlet temperature: 145°C<br />

shaft power: 2382 kW<br />

Control: combined hydraulic coupling and IVC<br />

(IVC located inside fan housing)<br />

Impeller blade shape: airfoiled<br />

Efficiency: 87,8%<br />

Mike Stuhl


World-wide service …<br />

Service safety<br />

Even the best quality product is only as good as<br />

the service backing it up. It is an adequate<br />

customer service that makes a corporate profile<br />

absolutely complete. We offer our customers the<br />

safety of excellent product quality within the<br />

framework of a comprehensive and individual<br />

service package.<br />

Efficiency as from hour 1<br />

You have to be able to use your fans and plants<br />

in an ideal way right from the beginning –<br />

technically as well as economically. With this aim<br />

in mind, our service team assists you both in word<br />

and deed, from installation and comissioning up<br />

tostaff training and maintenance.<br />

Installation and comissioning<br />

Our specialists mount your fans, comission up the<br />

plant and train your staff members in the correct<br />

handling in everyday use.<br />

Plant optimisation<br />

We can further improve the economic<br />

per<strong>for</strong>mance of your plant by targeted<br />

modifications and future-oriented upgrades.<br />

Wear, <strong>for</strong> example, can be minimised and the<br />

service life is increased.<br />

24-hour service<br />

If any faults occur, the services of our specialist<br />

staff are initiated within twenty-four hours. These<br />

staff members ensure fast diagnosis and<br />

implementation of solutions. Any spare and wearing<br />

parts required are manufactured, delivered and<br />

installed as fast as possible.<br />

World-wide service team<br />

Whether in power plants; in the chemicals,<br />

cement or mining industry; in tunnel ventilation or<br />

in wind tunnels: Our qualified service team has<br />

considerable experience in international missions<br />

and is available to you all over the world, if necessary.<br />

Stefan Schaum,<br />

Supervisor <strong>for</strong> errection and commissioning


Installation of a rotor<br />

in a power plant


Our contacts: Always in<br />

Ralph Mansius, Sales Manager


your immediate vicinity<br />

Germany<br />

Bad Hersfeld<br />

Germany<br />

Zweibrücken<br />

Russia<br />

Austria<br />

China<br />

Britain<br />

Benelux<br />

Chile<br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

Am Weinberg 68<br />

D-36251 Bad Hersfeld / Germany<br />

Telephone: +49 (6621) 95 02 51<br />

Facsimile: +49 (6621) 95 01 15<br />

Email: industrie@tlt.de<br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

Gleiwitzstrasse 7<br />

D-66482 Zweibrücken / Germany<br />

Telephone: +49 (6332) 80 80<br />

Facsimile: +49 (6332) 80 82 67<br />

Email: tlt@tlt.de<br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

ul. Profsojusnaja 45<br />

117 420 Moscow / Russia<br />

Telephone: +7 (9) 57 18 72 31<br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

Am Stadtpark 3 / 1734<br />

A-1030 Wien / Austria<br />

Telephone: +43 (1713) 40 30 10<br />

KK&K Beijing Representative Office<br />

22D Building E, Majestic Garden<br />

No. 6 North Sihuan Road<br />

100029 Chaoyang District, Beijing<br />

Telephone: +86 (10) 82 84 26 84<br />

KK&K-<strong>Turbo</strong> UK<br />

7 Regent Park, Park Farm Estate<br />

NN8 6GR Wellingborough, Northants<br />

Telephone: +44 (1933) 67 14 80<br />

KKK Benelux<br />

NL-8050 AA Hattem, Niederlande<br />

Telephone: +31 (38) 3756111<br />

KKK-Chile<br />

Vic. Mackenna 540 Of.36<br />

Temuco/Chile<br />

Telephone: +56 45 210 751<br />

Germany<br />

Frankenthal<br />

Germany<br />

Oberhausen<br />

Spain<br />

Australia<br />

India<br />

Japan<br />

Korea<br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

Hessheimer Strasse 2<br />

D-67227 Frankenthal / Germany<br />

Telephone: +49 (6233) 8 50<br />

Facsimile: +49 (6233) 85 26 70<br />

Email: tlt-ft@tlt.de<br />

<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

Havensteinstrasse 46<br />

D-46045 Oberhausen / Germany<br />

Telephone: +49 (208) 8 59 21 25<br />

Facsimile: +49 (208) 8 59 23 50<br />

Email: r.graeber@tlt.de<br />

Spanien<br />

PASCH Y CIA., S.A<br />

Capitán Haya, 9 1˚<br />

E-28020 Madrid / Spain<br />

Telephone: +34 (9) 15 98 37 60<br />

Australien<br />

Industrial Plant & Service<br />

99A South Creek Road<br />

2099 Dee Why West,<br />

Sydney<br />

Telephone: +61 -2- 99 8120 00<br />

Bharat Heavy Electricals Ltd.<br />

Boiler Auxiliaries Plant<br />

Ranipet - 632 406, Tamil Nadu<br />

Telephone: +91 (4172) 241190<br />

DMW Corporation<br />

5-1, Omori Kita 1-Chome Ota-Ku<br />

Tokyo 143-8558<br />

Telephone: +81 (3) 3298 5131<br />

Suewon Poongryuk Machinery Co.<br />

791-2, Kwanyang-Dong<br />

Dongan-Gu, Anyang<br />

Telephone: +82 (02) 863 6491


<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />

Industrial <strong>Fans</strong><br />

Am Weinberg 68<br />

D-36251 Bad Hersfeld / Germany<br />

Telephone: + 49 (6621) 950-251<br />

Facsimile: + 49 (6621) 950-115<br />

Email: industrie@tlt.de<br />

Web site: www.tlt.de<br />

© 2008 by <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong> · Matthias Bopp · 3th edition 08/08/PDF/Bopp · Subject to error and modifications.