Booster Fans for Power Plants - TLT Turbo GmbH
Booster Fans for Power Plants - TLT Turbo GmbH
Booster Fans for Power Plants - TLT Turbo GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Centrifugal <strong>Fans</strong><br />
▲ <strong>for</strong> <strong>Power</strong> <strong>Plants</strong><br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong>
Radialfans<br />
<strong>for</strong> <strong>Power</strong> <strong>Plants</strong><br />
Engineering and progress in air technology<br />
The requirements imposed on Industrial <strong>Fans</strong> have noticeably<br />
increased over the years.<br />
The variety of problems that need to be tackled when handling<br />
gases requires a comprehensive range of fans to optimize<br />
the selection <strong>for</strong> each particular application.<br />
Decades of intensive research and operating experience<br />
gained during this time are the basis <strong>for</strong> our fan range that<br />
provides the best economical choice <strong>for</strong> any application.<br />
Guiding factors <strong>for</strong> the development of this range have<br />
been:<br />
• Low Investment Cost<br />
• Low Operating Cost<br />
• High Reliability<br />
• Long Life<br />
• High Noise Attenuation<br />
Werner Glöckner,<br />
Division Manager - Industrial fans<br />
At the beginning of 2003, <strong>TLT</strong> was taken over by<br />
AG Kühnle, Kopp und Kausch, and since has<br />
been trading under the name of <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
as an independent company within the group.<br />
The affiliation with the KK&K Group gives us the<br />
opportunity to even better use the big development<br />
potential in the field of air technology engineering.<br />
Together we are strong.
Since more than<br />
130 years ...<br />
<strong>TLT</strong> workshop<br />
in Bad Hersfeld
fans from Bad Hersfeld<br />
Tradition and development.<br />
In 1874, when Benno Schilde and August Büttner<br />
started their own enterprises independently from<br />
each other, neither of them anticipated that more<br />
than 130 years later there would be in Bad<br />
Hersfeld one of the most modern manufacturing<br />
places.<br />
They started with " Exhausters”, first mainly made<br />
out of Cast Iron. Later steel plates were used,<br />
reducing weight and costs. Our engineers moved<br />
on and developed fans of highest quality and<br />
most reliable technology.<br />
Based on this tradition, a most successful company<br />
developed with highly innovative products.<br />
For nearly all industrial applications our fans are<br />
used in various designs.<br />
Today, <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong> offers a complete programme<br />
<strong>for</strong> the different industries.<br />
Heike Blum,<br />
Secretary
Abnahmeprüfung<br />
Quality production
Safe, reliable and economical<br />
With few exceptions, the large variety of available fan types nearly<br />
always permits direct coupling of the fan to the drive motor. We<br />
prefer this arrangement because system reliability is optimizied by<br />
avoiding interconnecting equipment such as gear boxes, belt drives,<br />
etc.<br />
The basic design flexibility of our fans permitting alterations to or<br />
replacement of the impeller enables us to match actual operating<br />
conditions if it is found during operation that they differ from the<br />
conditions on which the original design data are based.<br />
Furthermore, blade tip adjustment on centrifugal fan wheels is in<br />
many cases, a simple mean to meet specific operating conditions.<br />
from start to finish
Quality assurance: We<br />
Tested safety<br />
Our quality assurance system guarantees perfect products on a<br />
constantly high level – in material, workmanship, technology and<br />
function as well as in user and operating safety.<br />
Quality of a product is determined in its development phase<br />
already. For this reason, our quality assurance starts no later than<br />
at this stage.<br />
The fan range of <strong>TLT</strong> includes:<br />
Single or multi stage centrifugal fans<br />
with maximum efficiency at pressures<br />
up to 50.000 Pa. Standart and heavy<br />
duty designs are available.<br />
Double width double inlet centrifugal<br />
fans <strong>for</strong> large flow volume. Standart<br />
and heavy duty designs are available.<br />
Centrifugal fan, rotor supported on<br />
both sides, fan supportded by an integral<br />
steel frame.
set standards<br />
Our staff consider quality as a decisive element in their daily work.<br />
It belongs to their most important tasks to continuously check our<br />
quality assurance system and to update it, if and when necessary.<br />
Thus, its effectiveness is ensured permanently.<br />
Our quality management in compliance with DIN ISO EN<br />
9001 ensures that all materials we process, manufactured<br />
components, assemblies, individual products and complete<br />
system meet the high requirements.<br />
We obriously adhire to national and international standards<br />
and laws as well as to all contractual regulations.<br />
Thomas Koch,<br />
Head of design departement
Impeller with airfoild<br />
Impeller with airfoiled blades <strong>for</strong> I.D, PA and FD-<strong>Fans</strong>.<br />
High effiency (up to 90%) will reduce operating costs to a minimum level.<br />
Airfolied blades inside rein<strong>for</strong>ced<br />
Impeller, during balancing in the <strong>TLT</strong>-<strong>Turbo</strong> workshop, <strong>for</strong> an I.D. Fan in a<br />
power plant in Taichung (Taiwan).<br />
Technical Datas:<br />
Volume flow: 518,9 m 3 /s<br />
Total pressure increase: 10415 Pa<br />
Temperature: 160°C<br />
Speed: 890 rpm<br />
Shaft power: 5792 kW<br />
Efficiency: 90 %<br />
Impeller diameter: 3550 mm<br />
Tip speed: 165 m/s<br />
Year of delivery: 2002<br />
Control: with inlet vane control
lades…<br />
Impeller with airfoiled blades <strong>for</strong> I.D., PA and FD <strong>Fans</strong><br />
Volume flow up to 800 m 3 /s<br />
Pressure increase up to 15000Pa<br />
Shaft power up to 7000 kW<br />
Casing <strong>for</strong> a PA fan <strong>for</strong> a power plant in Iskenderun (Turkey).<br />
Technical Datas:<br />
Volume flow: 115 m 3 /s<br />
total pressure increase: 19766 Pa<br />
Shaft power: 1858 kW<br />
Efficiency: 87,1%<br />
impeller diameter: 2066 mm<br />
Tip speed: 161 m/s<br />
Year of delivery: 2003<br />
<strong>for</strong> <strong>Power</strong> <strong>Plants</strong>
<strong>Booster</strong> Fan<br />
<strong>Booster</strong> <strong>Fans</strong> <strong>for</strong><br />
<strong>Power</strong> <strong>Plants</strong><br />
<strong>Booster</strong> fan <strong>for</strong> a power plant in Yeniköy (Turkey)<br />
Technical Datas:<br />
Volume flow: 755,1 m 3 /s<br />
Total pressure increase: 3377 Pa<br />
Temperature: 153°C<br />
Shaft power: 2866 kW<br />
Efficiency: 88%<br />
Speed: 495 rpm<br />
Impeler diameters: 4160 mm<br />
Tip speed: 108 m/s<br />
Year of delivery: 2000<br />
Control: inlet vane controll,<br />
IVC located inside the housing<br />
This is the fan with the highest volume flow, <strong>TLT</strong>-<strong>Turbo</strong><br />
have manufactured as a centrifugal fan.<br />
Ralf Schreiber,<br />
Sales Engineer
Stainless steel application<br />
Rotor <strong>for</strong> a booster Fan <strong>for</strong> a FGD Plant in<br />
Brindisi (Italy) <strong>for</strong> corrosive medium (SO 2)<br />
Impeller in stainless steel (1.4565) =<br />
X2CRNIMnMoN25-18-6-5<br />
shaft rubber lined<br />
Technical Datas:<br />
Volume flow: 563 m 3 /s<br />
Pressure increase: 8155 Pa<br />
Shaft power: 5054 kW<br />
Efficiency: 88,3%<br />
Impeller diameter: 4050 mm<br />
Tip speed: 123 m/s<br />
Year of delivery: 2004<br />
Drilling the<br />
impeller hub<br />
Stainless<br />
Steel Rotor<br />
Stain
less Steel Application
Impeller with single t<br />
Impeller with single thickness blades <strong>for</strong> pressure increases up to 30000 Pa<br />
(single stage). For pressure increases up to 50000 Pa (double stage).<br />
We built single-stage radial flow-fans <strong>for</strong> a specific energy of<br />
more than 40000 J/kg. It depends on the case of need, temperature,<br />
volume/pressure ratio and the possible speed from what<br />
pressure increase the fan has to be of the double-stage type.<br />
Mill Fan <strong>for</strong> a power plant in Voerck (Germany)
hickness blades<br />
straight blades<br />
inlet angle: 60°<br />
outlet angle: 78°<br />
application <strong>for</strong> adhasive dust<br />
impeller backward curved, high pressure increase at high<br />
efficiency.<br />
inlet angle: 35°<br />
outlet angle: from 40-45°<br />
<strong>for</strong>warded curved blade<br />
inlet angle: 40°<br />
outlet angle: 90°<br />
application <strong>for</strong> wet dust<br />
Curved backward inclined blade profile <strong>for</strong> dust application<br />
which optimizes efficiency and minimizes build up.<br />
Most of the dust passes through the impeller without getting<br />
trapped and without creating major build up.<br />
inlet angle: 45°<br />
outlet angle: 45°
Per<strong>for</strong>mance Test in t<br />
Per<strong>for</strong>mance test <strong>for</strong> an I.D. Fan and a F.D. Fan, with reduced speed, driven by diesel<br />
engine, in the <strong>TLT</strong>-<strong>Turbo</strong> workshop. <strong>TLT</strong>-<strong>Turbo</strong> delivered 4 I.D. <strong>Fans</strong>, 4 F.D <strong>Fans</strong> and 4<br />
P.A <strong>Fans</strong> <strong>for</strong> the SSAA <strong>Power</strong> Station 3 in Malysia in 1996.<br />
Technical datas F.D Fan type 14144ZA1920<br />
Volume flow: 304,3 m 3 /s<br />
Pressure increase: 4454 Pa<br />
Inlet temperature: 40°C<br />
Shaft power: 1509 kW<br />
Control: combined hydraulic coupling and IVC<br />
(ICC located inside fan housing)<br />
Impeller blade shape: airfoiled<br />
Efficiency: 88,1%
e <strong>TLT</strong> workshop<br />
Technical Datas I.D. Fan Type 14144ZA2282<br />
Volume Flow: 432 m_/s<br />
Pressure increase: 4941 Pa<br />
inlet temperature: 145°C<br />
shaft power: 2382 kW<br />
Control: combined hydraulic coupling and IVC<br />
(IVC located inside fan housing)<br />
Impeller blade shape: airfoiled<br />
Efficiency: 87,8%<br />
Mike Stuhl
World-wide service …<br />
Service safety<br />
Even the best quality product is only as good as<br />
the service backing it up. It is an adequate<br />
customer service that makes a corporate profile<br />
absolutely complete. We offer our customers the<br />
safety of excellent product quality within the<br />
framework of a comprehensive and individual<br />
service package.<br />
Efficiency as from hour 1<br />
You have to be able to use your fans and plants<br />
in an ideal way right from the beginning –<br />
technically as well as economically. With this aim<br />
in mind, our service team assists you both in word<br />
and deed, from installation and comissioning up<br />
tostaff training and maintenance.<br />
Installation and comissioning<br />
Our specialists mount your fans, comission up the<br />
plant and train your staff members in the correct<br />
handling in everyday use.<br />
Plant optimisation<br />
We can further improve the economic<br />
per<strong>for</strong>mance of your plant by targeted<br />
modifications and future-oriented upgrades.<br />
Wear, <strong>for</strong> example, can be minimised and the<br />
service life is increased.<br />
24-hour service<br />
If any faults occur, the services of our specialist<br />
staff are initiated within twenty-four hours. These<br />
staff members ensure fast diagnosis and<br />
implementation of solutions. Any spare and wearing<br />
parts required are manufactured, delivered and<br />
installed as fast as possible.<br />
World-wide service team<br />
Whether in power plants; in the chemicals,<br />
cement or mining industry; in tunnel ventilation or<br />
in wind tunnels: Our qualified service team has<br />
considerable experience in international missions<br />
and is available to you all over the world, if necessary.<br />
Stefan Schaum,<br />
Supervisor <strong>for</strong> errection and commissioning
Installation of a rotor<br />
in a power plant
Our contacts: Always in<br />
Ralph Mansius, Sales Manager
your immediate vicinity<br />
Germany<br />
Bad Hersfeld<br />
Germany<br />
Zweibrücken<br />
Russia<br />
Austria<br />
China<br />
Britain<br />
Benelux<br />
Chile<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Am Weinberg 68<br />
D-36251 Bad Hersfeld / Germany<br />
Telephone: +49 (6621) 95 02 51<br />
Facsimile: +49 (6621) 95 01 15<br />
Email: industrie@tlt.de<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Gleiwitzstrasse 7<br />
D-66482 Zweibrücken / Germany<br />
Telephone: +49 (6332) 80 80<br />
Facsimile: +49 (6332) 80 82 67<br />
Email: tlt@tlt.de<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
ul. Profsojusnaja 45<br />
117 420 Moscow / Russia<br />
Telephone: +7 (9) 57 18 72 31<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Am Stadtpark 3 / 1734<br />
A-1030 Wien / Austria<br />
Telephone: +43 (1713) 40 30 10<br />
KK&K Beijing Representative Office<br />
22D Building E, Majestic Garden<br />
No. 6 North Sihuan Road<br />
100029 Chaoyang District, Beijing<br />
Telephone: +86 (10) 82 84 26 84<br />
KK&K-<strong>Turbo</strong> UK<br />
7 Regent Park, Park Farm Estate<br />
NN8 6GR Wellingborough, Northants<br />
Telephone: +44 (1933) 67 14 80<br />
KKK Benelux<br />
NL-8050 AA Hattem, Niederlande<br />
Telephone: +31 (38) 3756111<br />
KKK-Chile<br />
Vic. Mackenna 540 Of.36<br />
Temuco/Chile<br />
Telephone: +56 45 210 751<br />
Germany<br />
Frankenthal<br />
Germany<br />
Oberhausen<br />
Spain<br />
Australia<br />
India<br />
Japan<br />
Korea<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Hessheimer Strasse 2<br />
D-67227 Frankenthal / Germany<br />
Telephone: +49 (6233) 8 50<br />
Facsimile: +49 (6233) 85 26 70<br />
Email: tlt-ft@tlt.de<br />
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Havensteinstrasse 46<br />
D-46045 Oberhausen / Germany<br />
Telephone: +49 (208) 8 59 21 25<br />
Facsimile: +49 (208) 8 59 23 50<br />
Email: r.graeber@tlt.de<br />
Spanien<br />
PASCH Y CIA., S.A<br />
Capitán Haya, 9 1˚<br />
E-28020 Madrid / Spain<br />
Telephone: +34 (9) 15 98 37 60<br />
Australien<br />
Industrial Plant & Service<br />
99A South Creek Road<br />
2099 Dee Why West,<br />
Sydney<br />
Telephone: +61 -2- 99 8120 00<br />
Bharat Heavy Electricals Ltd.<br />
Boiler Auxiliaries Plant<br />
Ranipet - 632 406, Tamil Nadu<br />
Telephone: +91 (4172) 241190<br />
DMW Corporation<br />
5-1, Omori Kita 1-Chome Ota-Ku<br />
Tokyo 143-8558<br />
Telephone: +81 (3) 3298 5131<br />
Suewon Poongryuk Machinery Co.<br />
791-2, Kwanyang-Dong<br />
Dongan-Gu, Anyang<br />
Telephone: +82 (02) 863 6491
<strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong><br />
Industrial <strong>Fans</strong><br />
Am Weinberg 68<br />
D-36251 Bad Hersfeld / Germany<br />
Telephone: + 49 (6621) 950-251<br />
Facsimile: + 49 (6621) 950-115<br />
Email: industrie@tlt.de<br />
Web site: www.tlt.de<br />
© 2008 by <strong>TLT</strong>-<strong>Turbo</strong> <strong>GmbH</strong> · Matthias Bopp · 3th edition 08/08/PDF/Bopp · Subject to error and modifications.