Use the spigot wrench 282 661.<br />

Rear shell view<br />

Ribbon cable should be fitted with contacts before<br />

moun!ing.<br />

1 If ribbon cable is less than 3. 7 thick, use the reducer. In<br />

the other cases (ribbon cable thickness between 3.7<br />

and 6.5) reducer is not necessary.<br />

Be careful : the backshe/1 can only be mounted one<br />

way round, so ensure that ribbon cable is located in<br />

correct cavity A or B.<br />

2 Engage the ribbon cable in the open side of the backshell<br />

3 Fit the contacts into the insert module.<br />

4 Install the insert module into the shell.<br />

Locking screw<br />

5 Apply some thread lock onto the accessory thread of the connector shell.<br />

Reducer for thin ribbon cable<br />

•<br />

1--Fixing screws of cable clamp<br />

6 Mount the backs hell onto the rear of the connector. Ensure that the locking screw is correctly positioned on the polarizing<br />

key accessory thread.<br />

7 Screw and tighten the locking screw with spigot wrench .<br />

8 Attach the cable clamp using the fixing screws.<br />

9 Push the ribbon cable into the backshell so that there is some slack when the clamp is tightened.<br />

10 Tighten the clamp to trap the ribbon cable.<br />

Use the spigot wrench 282 661.<br />

1 Feed the twisted pair cable through the outlet of the<br />

backshell.<br />

2 Strip and terminate the twisted pair cable.<br />

3 Fit the contacts into the insert module.<br />

4 Install the insert module into the shell.<br />

5 Apply some thread lock onto the accessory thread of<br />

the connector shell.<br />

6 Mount the backshell onto the rear of the connector.<br />

Ensure that the locking screw is correctly positioned<br />

on the polarizing key accessory thread.<br />

7 Screw and tighten the locking screw with the spigot<br />

wrench.<br />

8 Clamp the twisted pair cable with a Ty-Rap® in the slot<br />

of the outlet.<br />

Outlet of the backs hell<br />

<strong>Uncontrolled</strong> Copy<br />

Locking screw<br />

Slot<br />

® Trade Mark of Thomas & Betts Corp.<br />

RADIALL<br />

The Quality Connectio n<br />

-59-