■ C <strong>Drive</strong> Unit<br />
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●<br />
■Allowable Radial Loads on Low Speed Shaft<br />
Allowable Radial Loads on Low Speed Shaft F rA [kN]<br />
Reduction<br />
5~45<br />
Ratio<br />
Shaft<br />
Speed<br />
Size of Reducer<br />
(r/min) 1010 1020 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140<br />
100 5.0 5.4 6.7 8.9 11.7 18.0 23.6 47.5 48.5 92.6 112 132 148 184<br />
60 5.9 6.4 7.9 10.5 13.9 21.3 28.0 56.2 69.4 108 131 154 173 214<br />
40 6.8 7.3 9.0 12.0 16.0 24.4 32.1 64.4 79.4 122 148 174 195 242<br />
20 8.4 9.2 11.3 15.2 21.1 30.8 40.4 80.6 100 150 182 215 240 298<br />
10 8.4 10.9 13.8 19.1 25.4 38.8 50.9 80.6 116 178 224 264 296 366<br />
5 8.4 10.9 13.8 19.4 26.7 42.1 59.8 80.6 116 178 225 269 306 393<br />
Allowable Radial Loads on Low Speed Shaft F rA [kN]<br />
Reduction<br />
50~1400<br />
Ratio<br />
Shaft<br />
Speed<br />
Size of Reducer<br />
(r/min) 1010 1020 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160<br />
100 5.0 5.4 6.7 8.9 11.7 18.0 23.6 47.5 48.5 92.6 117 132 167 227 235 378<br />
60 5.9 6.4 7.9 10.5 13.9 21.3 28.0 56.2 69.4 108 136 154 195 264 274 441<br />
40 6.8 7.3 9.0 12.0 16.0 24.4 32.1 64.4 79.4 122 153 174 220 298 310 498<br />
20 8.4 9.2 11.3 15.2 21.1 30.8 40.4 80.6 100 150 189 215 271 367 381 602<br />
10 8.4 10.9 13.8 19.1 25.4 38.8 50.9 80.6 116 178 233 264 333 452 469 602<br />
5 8.4 10.9 13.8 19.4 26.7 42.1 59.8 80.6 116 178 248 269 396 461 498 602<br />
Overhang Factor K3<br />
Overhang Member<br />
Overhang Factor<br />
Sprocket (Single Row) 1<br />
Sprocket (Double Row) 1.25<br />
<strong>Gear</strong>s 1.25<br />
V-belt 1.5<br />
Flat belt 2.5<br />
F r<br />
Note: The value shown in the above table is allowable radial load when it is applied to the center of the shaft. Consult us<br />