DIMENSIONS
DIMENSIONS & PROPERTIES - Steel & Tube
DIMENSIONS & PROPERTIES - Steel & Tube
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
UP<br />
Ultrapipe<br />
Circular<br />
hollow<br />
sections<br />
Class 2A – AS 4041 Maximum operating pressures in MPa for UltraPipe<br />
Fluid 1 Fluid 2 Fluid 3 Fluid 3 Fluid 4<br />
Gas Gas Liquid Liquid<br />
Design Strength MPa f 176 156 176 156 176 156 176 156 176 156<br />
Thickness tolerance factor 0.925 0.925 0.925 0.925 0.925 0.925 0.925 0.925 0.925 0.925<br />
Piping class factor M 1 1 1 1 1 1 1 1 1 1<br />
Weld joint factor e 1 1 1 1 1 1 1 1 1 1<br />
Maximum Operating Temperature<br />
Ambient 100ºC Ambient 100ºC Ambient 100ºC Ambient 100ºC Ambient 100ºC<br />
OD WT MDMTºC<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
-20<br />
-25<br />
-40<br />
12.7<br />
9.5<br />
6.4<br />
457.0<br />
457.0<br />
457.0<br />
9.3<br />
6.9<br />
4.6<br />
10.5<br />
7.8<br />
5.2<br />
9.3<br />
6.9<br />
4.6<br />
10.5<br />
7.8<br />
5.2<br />
9.3<br />
6.9<br />
4.6<br />
10.0<br />
7.8<br />
5.2<br />
10.0<br />
6.9<br />
4.6<br />
Class 1 – AS 4041 Maximum operating pressures in MPa for UltraPipe<br />
Fluid 1 Fluid 2 Fluid 3 Fluid 4<br />
Design Strength MPa f 176 156 176 156 176 156 176 156<br />
Thickness tolerance factor 0.925 0.925 0.925 0.925 0.925 0.925 0.925 0.925<br />
Piping class factor M 1 1 1 1 1 1 1 1<br />
Weld joint factor e 1 1 1 1 1 1 1 1<br />
OD WT MDMTºC<br />
457.0<br />
457.0<br />
457.0<br />
406.4<br />
406.4<br />
406.4<br />
355.6<br />
355.6<br />
355.6<br />
323.9<br />
323.9<br />
323.9<br />
273.1<br />
273.1<br />
273.1<br />
273.1<br />
12.7<br />
9.5<br />
6.4<br />
12.7<br />
9.5<br />
6.4<br />
12.7<br />
9.5<br />
6.4<br />
12.7<br />
9.5<br />
6.4<br />
12.7<br />
9.3<br />
6.4<br />
4.8<br />
-20<br />
-25<br />
-40<br />
-20<br />
-25<br />
-40<br />
-20<br />
-25<br />
-40<br />
-20<br />
-25<br />
-40<br />
-20<br />
-25<br />
-40<br />
-50<br />
Maximum Operating Temperature<br />
Ambient 100ºC Ambient 100ºC Ambient 100ºC Ambient 100ºC<br />
9.3<br />
6.9<br />
4.6<br />
10.5<br />
7.8<br />
5.2<br />
12.1<br />
9.0<br />
6.0<br />
13.3<br />
9.9<br />
6.6<br />
15.9<br />
11.5<br />
7.8<br />
5.9<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
10.7<br />
8.0<br />
5.3<br />
11.8<br />
8.8<br />
5.8<br />
14.1<br />
10.2<br />
7.0<br />
5.2<br />
9.3<br />
6.9<br />
4.6<br />
10.5<br />
7.8<br />
5.2<br />
12.1<br />
9.0<br />
6.0<br />
13.3<br />
9.9<br />
6.6<br />
15.9<br />
11.5<br />
7.8<br />
5.9<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
10.7<br />
8.0<br />
5.3<br />
11.8<br />
8.8<br />
5.8<br />
14.1<br />
10.2<br />
7.0<br />
5.2<br />
9.3<br />
6.9<br />
4.6<br />
10.5<br />
7.8<br />
5.2<br />
12.1<br />
9.0<br />
6.0<br />
13.3<br />
9.9<br />
6.6<br />
15.9<br />
11.5<br />
7.8<br />
5.9<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
10.7<br />
8.0<br />
5.3<br />
11.8<br />
8.8<br />
5.8<br />
14.1<br />
10.2<br />
7.0<br />
5.2<br />
9.3<br />
6.9<br />
4.6<br />
10.5<br />
7.8<br />
5.2<br />
12.1<br />
9.0<br />
6.0<br />
13.3<br />
9.9<br />
6.6<br />
15.9<br />
11.5<br />
7.8<br />
5.9<br />
8.3<br />
6.2<br />
4.1<br />
9.3<br />
6.9<br />
4.6<br />
10.7<br />
8.0<br />
5.3<br />
11.8<br />
8.8<br />
5.8<br />
14.1<br />
10.2<br />
7.0<br />
5.2<br />
219.1<br />
219.1<br />
219.1<br />
219.1<br />
168.3<br />
168.3<br />
168.3<br />
114.3<br />
114.3<br />
88.9<br />
88.9<br />
8.2<br />
6.4<br />
4.8<br />
4.0<br />
7.1<br />
6.4<br />
4.8<br />
6.0<br />
4.8<br />
5.5<br />
4.8<br />
-30<br />
-40<br />
-50<br />
-50<br />
-35<br />
-40<br />
-50<br />
-45<br />
-50<br />
-45<br />
-50<br />
12.7<br />
9.8<br />
7.3<br />
6.1<br />
14.4<br />
12.9<br />
9.6<br />
18.1<br />
14.3<br />
21.5<br />
18.6<br />
11.3<br />
8.7<br />
6.5<br />
5.4<br />
12.7<br />
11.4<br />
8.5<br />
10.0<br />
7.8<br />
5.2<br />
16.0<br />
12.7<br />
19.1<br />
16.5<br />
This class is<br />
not suitable for<br />
fluid 1<br />
12.7<br />
9.8<br />
7.3<br />
6.1<br />
-20<br />
-25<br />
-40<br />
14.4<br />
12.9<br />
9.6<br />
12.7<br />
9.5<br />
6.4<br />
18.1<br />
14.3<br />
21.5<br />
18.6<br />
406.4<br />
406.4<br />
406.4<br />
11.3<br />
8.7<br />
6.5<br />
5.4<br />
10.7<br />
8.0<br />
5.3<br />
12.7<br />
11.4<br />
8.5<br />
12.1<br />
9.0<br />
6.0<br />
16.0<br />
12.7<br />
19.1<br />
16.5<br />
10.7<br />
8.0<br />
5.3<br />
12.7<br />
9.8<br />
7.3<br />
6.1<br />
12.1<br />
9.0<br />
6.0<br />
14.4<br />
12.9<br />
9.6<br />
10.0<br />
8.0<br />
5.3<br />
18.1<br />
14.3<br />
21.5<br />
18.6<br />
10.0<br />
9.0<br />
6.0<br />
11.3<br />
8.7<br />
6.5<br />
5.4<br />
12.7<br />
11.4<br />
8.5<br />
16.0<br />
12.7<br />
19.1<br />
16.5<br />
12.7<br />
9.8<br />
7.3<br />
6.1<br />
10.0<br />
8.0<br />
5.3<br />
14.4<br />
12.9<br />
9.6<br />
18.1<br />
14.3<br />
21.5<br />
18.6<br />
11.3<br />
8.7<br />
6.5<br />
5.4<br />
12.7<br />
11.4<br />
8.5<br />
16.0<br />
12.7<br />
19.1<br />
16.5<br />
Note 1: For other temperatures consult AS4041 for appropriate pressure ratings.<br />
Note 2: MDMT = Material Design Minimum Temperature.<br />
10.0<br />
9.0<br />
6.0<br />
-20<br />
-25<br />
-40<br />
12.7<br />
9.5<br />
6.4<br />
355.6<br />
355.6<br />
355.6<br />
11.8<br />
8.8<br />
5.8<br />
13.3<br />
9.9<br />
6.6<br />
11.8<br />
8.8<br />
5.8<br />
13.3<br />
9.9<br />
6.6<br />
10.0<br />
8.8<br />
5.8<br />
10.0<br />
9.9<br />
6.6<br />
10.0<br />
8.8<br />
5.8<br />
10.0<br />
9.9<br />
6.6<br />
-20<br />
-25<br />
-40<br />
12.7<br />
9.5<br />
6.4<br />
323.9<br />
323.9<br />
323.9<br />
14.1<br />
10.2<br />
7.0<br />
5.2<br />
15.9<br />
11.5<br />
7.8<br />
5.9<br />
14.1<br />
10.2<br />
7.0<br />
5.2<br />
15.9<br />
11.5<br />
7.8<br />
5.9<br />
10.0<br />
10.0<br />
7.0<br />
5.2<br />
10.0<br />
10.0<br />
7.8<br />
5.9<br />
10.0<br />
10.0<br />
7.0<br />
5.2<br />
10.0<br />
10.0<br />
7.8<br />
5.9<br />
-20<br />
-25<br />
-40<br />
-50<br />
12.7<br />
9.3<br />
6.4<br />
4.8<br />
273.1<br />
273.1<br />
273.1<br />
273.1<br />
11.3<br />
8.7<br />
6.5<br />
5.4<br />
12.7<br />
9.8<br />
7.3<br />
6.1<br />
11.3<br />
8.7<br />
6.5<br />
5.4<br />
12.7<br />
9.8<br />
7.3<br />
6.1<br />
10.0<br />
8.7<br />
6.5<br />
5.4<br />
10.0<br />
9.8<br />
7.3<br />
6.1<br />
10.0<br />
8.7<br />
6.5<br />
5.4<br />
10.0<br />
9.8<br />
7.3<br />
6.1<br />
This class is<br />
not suitable for<br />
fluid 1<br />
-30<br />
-40<br />
-50<br />
-50<br />
8.2<br />
6.4<br />
4.8<br />
4.0<br />
219.1<br />
219.1<br />
219.1<br />
219.1<br />
12.7<br />
11.4<br />
8.5<br />
14.4<br />
12.9<br />
9.6<br />
12.7<br />
11.4<br />
8.5<br />
14.4<br />
12.9<br />
9.6<br />
10.0<br />
10.0<br />
8.5<br />
10.0<br />
10.0<br />
9.6<br />
10.0<br />
10.0<br />
8.5<br />
10.0<br />
10.0<br />
9.6<br />
-35<br />
-40<br />
-50<br />
7.1<br />
6.4<br />
4.8<br />
168.3<br />
168.3<br />
168.3<br />
16.0<br />
12.7<br />
19.1<br />
16.5<br />
18.1<br />
14.3<br />
21.5<br />
18.6<br />
16.0<br />
12.7<br />
19.1<br />
16.5<br />
18.1<br />
14.3<br />
21.5<br />
18.6<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
10.0<br />
This class is<br />
not suitable for<br />
fluid 1<br />
-45<br />
-50<br />
-45<br />
-50<br />
6.0<br />
4.8<br />
5.5<br />
4.8<br />
114.3<br />
114.3<br />
88.9<br />
88.9<br />
Note 1: For other temperatures consult AS4041 for appropriate pressure ratings.<br />
Note 2: MDMT = Material Design Minimum Temperature.<br />
94<br />
Dimensions and Properties Handbook