Air-Operated Diaphragm Pumps VERDER VA 15 VERDER VA 15 VERDER VA 20
verderair va 20 - Double Diaphragm Pump
verderair va 20 - Double Diaphragm Pump
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>VERDER</strong> <strong>VA</strong> <strong>15</strong> and <strong>VA</strong> <strong>20</strong> Performance<br />
Charts<br />
Fluid Outlet Pressure<br />
Test Conditions: Pump tested in water with inlet submerged.<br />
100<br />
(0.7, 7)<br />
FLUID OUTLET PRESSURE – psi; MPa (bar)<br />
80<br />
(0.55, 5.5)<br />
60<br />
(0.41, 4.1)<br />
40<br />
(0.28, 2.8)<br />
<strong>20</strong><br />
(0.14, 1.4)<br />
A<br />
B<br />
C<br />
A<br />
B<br />
C<br />
Fluid Pressure Curves<br />
at 100 psi (0.7 MPa, 7 bar) air pressure<br />
at 70 psi (0.48 MPa, 4.8 bar) air pressure<br />
at 40 psi (0.28 MPa, 2.8 bar) air pressure<br />
0<br />
0 2 4 6 8 10 12 14 16<br />
(7.6) (<strong>15</strong>.2) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6)<br />
FLUID FLOW – gpm (lpm)<br />
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar):<br />
1. Locate fluid flow rate along bottom of chart.<br />
2. Follow vertical line up to intersection with selected fluid outlet pressure curve.<br />
3. Follow left to scale to read fluid outlet pressure.<br />
819.6900 35