Divisione Nucleare<br />
Progetto<br />
Project<br />
PDS-XADS<br />
<strong>AnsaldoEnergia</strong><br />
Identificativo<br />
Document no.<br />
XADS 20 TRIX 009<br />
Rev.<br />
Rev.<br />
1<br />
Cl. ris.<br />
class<br />
Pagina<br />
Page<br />
9<br />
XADS components/systems is provided to better understand the Master Logic Diagram<br />
constructed in the Sections from 3.3 to 3.6.<br />
Reactor System<br />
Provides the generation of energy from nuclear fission, and geometry for the<br />
thermohydraulic processes to take place. Provides neutron-shielding structures. Encloses<br />
the reactor coolant; provides Core supporting structures; provides a cover for the Reactor<br />
Vessel, inclusive of the mechanisms for fuel manipulation; provides a redundant barrier to<br />
contain the primary coolant in case of leakage (Guard Vessel).<br />
Reactor Coolant System<br />
Provides the lead-bismuth eutectic circulation to remove the energy from nuclear fission and<br />
beam radiation, as well as the means for transferring energy from the primary coolant to the<br />
secondary systems.<br />
Accelerator Beam Transport System<br />
Provides the transportation of the proton beam inside the Reactor Vessel.<br />
Reactor Proton Beam Target System<br />
Provides the interface between the proton beam and lead-bismuth spallation target, along<br />
with the related cooling functions.<br />
Primary Cover Gas System<br />
Provides storage, supply, circulation, confinement, and pressure control of the primary<br />
cover gas, and the gas for the in-Vessel enhanced circulation. Provides the radiological<br />
control and the decontamination of the primary cover gas. Provides the chemistry control of<br />
the reactor coolant.<br />
Target Enhanced Circulation System<br />
Provides a constant injection of Argon directly into the mass of the target coolant, to<br />
maintain the conditions required for sustaining the target coolant flow rate during normal<br />
plant operations.<br />
Reactor Integrated Purification System<br />
Provides the in-Vessel-integrated purification of the reactor coolant.<br />
Reactor Coolant Filling System<br />
DNU 020/1