Divisione Nucleare<br />
Progetto<br />
Project<br />
PDS-XADS<br />
<strong>AnsaldoEnergia</strong><br />
Identificativo<br />
Document no.<br />
XADS 20 TRIX 009<br />
Rev.<br />
Rev.<br />
1<br />
Cl. ris.<br />
class<br />
Pagina<br />
Page<br />
45<br />
The event [1.1.3] “CORE COMPACTION” assumes that all the Fuel Assemblies, in the most<br />
unlike event, can be packed together with the complete closure of the clearance between<br />
each Fuel Assembly wrapper.<br />
3.4.2 Decrease of fuel assembly heat removal<br />
These subsection addresses events that affect heat removal from a single fuel assembly<br />
and, as such may have a significant impact on the affected assembly while the effect on the<br />
core and on the primary system as negligible. Obviously, challenges to the fuel cladding<br />
integrity may derive also from other events discussed in next sections 3.5.<br />
The decrease of heat removal from a single fuel assembly can be attributed to the<br />
anomalies of the eutectic flowrate caused by fuel element failure. The MLD branch detailing<br />
the event “DECREASE of FUEL ASSEMBLY HEAT REMOVAL” is shown in the following<br />
Fig. 3.4-2; it identifies scenarios that represent level 3 of the MLD.<br />
Figure 3.4-2<br />
MLD development starting from<br />
" DECREASE of FUEL ASSEMBLY HEAT REMOVAL "<br />
[1.2]<br />
DECREASE of FUEL<br />
ASSEMBLY HEAT<br />
REMOVAL<br />
level 2<br />
[1.2.1]<br />
FUEL ASSEMBLY<br />
PARTIAL BLOCKAGE<br />
[1.2.2]<br />
FUEL ASSEMBLY<br />
MECHANICAL LOCK<br />
FAILURE<br />
level 3<br />
level 2 events description<br />
The "DECREASE of THE FUEL ASSEMBLY HEAT REMOVAL", event [1.2], can be<br />
originated by the following causes leading to an insufficient refrigeration of a single fuel<br />
assembly:<br />
• FUEL ASSEMBLY PARTIAL BLOCKAGE;<br />
• FUEL ASSEMBLY MECHANICAL LOCK FAILURE.<br />
DNU 020/1