cold leg temperature. The serial arrangement of the Air Coolers allows to fully exploiting<br />
their heat transfer capability, and provides wider control flexibility.<br />
The Air Coolers (see Figure 3.2-10) are provided with motor-operated variable speed fans,<br />
in order to select the desired heat removal rate during each plant operating condition. At low<br />
heat load, the air can flow on natural circulation and the flow rate can be controlled by<br />
means of movable dampers. The air exhausts are then discharged to the external<br />
atmosphere through a battery of stacks.<br />
The Expansion Tank is installed after the ACs upstream of the IHXs. This tank holds the oil<br />
volume fluctuations due to possible operating temperatures fluctuations and oil swelling<br />
from 60°C to 320°C.<br />
The recirculation pump, installed on the hot leg downstream of the IHXs, is sized to deliver<br />
100% of the required loop flow rate. Each pump is connectable to the on-site power<br />
generation bus (Diesel Generator) to be automatically actuated in case of a Loss of Off-Site<br />
Power. Separate power buses, belonging to the Non-Class normally feed 1E AC Power<br />
Systems (NACS the SCS pumps, loop 1 and 2, 1E AC Power Systems (NACS). This<br />
redundancy ensures a defense-in-depth capability against the possibility of a reactor<br />
shutdown.<br />
On high radioactivity signal from one SCS loop the corresponding recirculation pump is<br />
automatically stopped in order to terminate contaminated material recirculation; beside, the<br />
ACs air path is intercepted in order to terminate the natural recirculation. The reactor shall<br />
be shut down and the other available SCS loop shall be used to drive the plant to a<br />
controlled state.<br />
On low RCS temperature signal a total air coolers shutdown is automatically initiated in<br />
order to limit primary coolant temperature decrease, to try to maintain just above the LBE<br />
freezing point.<br />
A safety-relief valve protects the SCS from the potential overpressure caused by secondary<br />
coolant thermal expansion.<br />
Before start up phase’s gas pockets shall be eliminated through adequate vent lines, on the<br />
upper parts of the secondary circuit, connected to the Expansion Tank.<br />
The Expansion Tank and all the main loop piping are thermally insulated. This sections; one<br />
for each SCS loop, include the equipment necessary for filling/draining of each loop. These<br />
sections are also utilized for a continuous feed and bleed to perform the required oil<br />
purification. More specifically an oil drain line is provided to connect each loop to a<br />
dedicated Storage Tank capable of containing all the drainable coolant oil.<br />
DNU 020/1