Divisione Nucleare<br />

Progetto<br />

Project<br />

PDS-XADS<br />

<strong>AnsaldoEnergia</strong><br />

Identificativo<br />

Document no.<br />

XADS 20 TRIX 009<br />

Rev.<br />

Rev.<br />

1<br />

Cl. ris.<br />

class<br />

Pagina<br />

Page<br />

29<br />

However, at that time, there is still no consensus in the linac community on the best<br />

radiofrequency (RF) structures to use in the intermediate section (from 5 MeV to 100 MeV).<br />

There is some debate still open concerning the best structure to choose. This is why many<br />

different options are still open including a "warm option" (i.e. room temperature RF<br />

structure) and two superconducting options (crossbar and spoke cavity). Advantages and<br />

disadvantages of these different structure types can be compared, especially regarding the<br />

XADS specific requirements (reliability and tuning). But it is clear at this point that no definite<br />

solution will be firmly given for this intermediate section until some particular R&D has been<br />

finalized, laboratory performance demonstrated and a thorough comparison performed.<br />

Figure 3.2-12 illustrates the linac scheme.<br />

DNU 020/1