Divisione Nucleare<br />
Progetto<br />
Project<br />
PDS-XADS<br />
<strong>AnsaldoEnergia</strong><br />
Identificativo<br />
Document no.<br />
XADS 20 TRIX 009<br />
Rev.<br />
Rev.<br />
1<br />
Cl. ris.<br />
class<br />
Pagina<br />
Page<br />
49<br />
of the two loops at any reactor power level (see Fig. 3.2-9), provided by centrifugal pumps<br />
(one per loop). Due to the constant pump speed and to the absence of flow regulating<br />
devices no increase of the oil flowrate is can take place in the system).<br />
level 4 events description<br />
The event [2.1.1.1] "DECREASE OF ORGANIC FLUID TEMPERATURE" can be attributed<br />
to:<br />
• malfunctions of the SCS Air Coolers that lead to reject to the external air more heat than<br />
that removed from the primary system. It should be noted that, due to the performance<br />
of the SCS system, this phenomenology appears to have a weak impact at nominal plant<br />
power level; its impact becomes more and more significant for decreasing plant<br />
operating power.<br />
• malfunctions of the SCS Feed and Bleed System that lead to the decrease of oil storage<br />
tank temperature.<br />
level 5 events description<br />
Considering the event [2.1.1.1.1] "INCREASED AIR COOLERS HEAT REMOVAL", the<br />
MLD shows that it can derive from the malfunction that affect all Air Coolers of one SCS<br />
loop (3 out of 3 SCS AIR COOLERS MALFUNCTION) or from the malfunction that affect<br />
only one Air Cooler (1 out of 3 SCS AIR COOLERS MALFUNCTION).<br />
It is noted here that the XADS primary and secondary coolant temperatures control strategy<br />
is centered on the Air Coolers System which therefore is designed with a large degree of<br />
flexibility and provided with several regulating devices including variable speed fans,<br />
orientable fan valves, moving inlet and outlet louvers in each fan (see Fig 3.2-10).<br />
The drawback of this flexibility is then the large variety of malfunctions that can be<br />
postulated.<br />
Considering the event [2.1.1.1.2] "SECONDARY COOLANT FEED and BLEED SYSTEM<br />
MALFUNCTION", the MLD shows that it can derive from the malfunctions of the oil storage<br />
tank heaters. This event however is considered of small significance.<br />
DNU 020/1