PB104349A55<br />

PB104353A55<br />

PB104348A55<br />

PB104347A55<br />

Connections page A-39<br />

b Rear connection (horizontal or vertical).<br />

b Front connection.<br />

b Mixed connections.<br />

b Optional accessories:<br />

v bare-cable connectors <strong>and</strong> connector shields<br />

v terminal shields<br />

v vertical-connection adapters<br />

v cable-lug adapters<br />

v interphase barriers<br />

v spreaders<br />

v disconnectable front-connection adapter<br />

v safety shutters, shutter locking blocks, shutter<br />

position indication <strong>and</strong> locking.<br />

Locking page A-43<br />

b Pushbutton locking by padlockable transparent<br />

cover.<br />

b OFF-position locking by padlock or keylock.<br />

b Chassis locking in disconnected position by keylock.<br />

b Chassis locking in connected, disconnected<br />

<strong>and</strong> test positions.<br />

b Door interlock (inhibits door opening with breaker<br />

in connected position).<br />

b Racking interlock (inhibits racking with door open).<br />

b Racking interlock between crank <strong>and</strong> OFF<br />

pushbutton.<br />

b<br />

b<br />

Automatic spring discharge before breaker removal.<br />

Mismatch protection.<br />

Indication contacts page A-45<br />

b St<strong>and</strong>ard or low-level contacts:<br />

v ON/OFF indication (OF)<br />

v “fault trip” indication (SDE)<br />

v carriage switches for connected<br />

(CE) disconnected (CD) <strong>and</strong> test<br />

(CT) positions.<br />

b Programmable contacts:<br />

v 2 contacts (M2C)<br />

v 6 contacts (M6C).<br />

DB101111<br />

M2C contact.<br />

DB101156<br />

DB101149<br />

DB101110 DB101109<br />

DB101112<br />

OF contact.<br />

Remote operation page A-47<br />

b Remote ON/OFF:<br />

v gear motor<br />

v XF closing or MX opening voltage releases<br />

v PF ready-to-close contact<br />

options: RAR automatic or RES electrical remote reset<br />

- BPFE electrical closing pushbutton.<br />

b Remote tripping function:<br />

v MN voltage release<br />

- st<strong>and</strong>ard<br />

- adjustable or non-adjustable delay<br />

v or second MX voltage release.<br />

Gear motor.<br />

DB101113<br />

DB101147<br />

DB101114<br />

DB101150<br />

MX, XF <strong>and</strong> MN volage<br />

releases.<br />

Accessories page A-51<br />

b Auxiliary terminal shield.<br />

b Operation counter.<br />

b Escutcheon.<br />

b Transparent cover for escutcheon.<br />

b Escutcheon blanking plate.<br />

DB101115<br />