PB104349A55<br />
PB104353A55<br />
PB104348A55<br />
PB104347A55<br />
Connections page A-39<br />
b Rear connection (horizontal or vertical).<br />
b Front connection.<br />
b Mixed connections.<br />
b Optional accessories:<br />
v bare-cable connectors <strong>and</strong> connector shields<br />
v terminal shields<br />
v vertical-connection adapters<br />
v cable-lug adapters<br />
v interphase barriers<br />
v spreaders<br />
v disconnectable front-connection adapter<br />
v safety shutters, shutter locking blocks, shutter<br />
position indication <strong>and</strong> locking.<br />
Locking page A-43<br />
b Pushbutton locking by padlockable transparent<br />
cover.<br />
b OFF-position locking by padlock or keylock.<br />
b Chassis locking in disconnected position by keylock.<br />
b Chassis locking in connected, disconnected<br />
<strong>and</strong> test positions.<br />
b Door interlock (inhibits door opening with breaker<br />
in connected position).<br />
b Racking interlock (inhibits racking with door open).<br />
b Racking interlock between crank <strong>and</strong> OFF<br />
pushbutton.<br />
b<br />
b<br />
Automatic spring discharge before breaker removal.<br />
Mismatch protection.<br />
Indication contacts page A-45<br />
b St<strong>and</strong>ard or low-level contacts:<br />
v ON/OFF indication (OF)<br />
v “fault trip” indication (SDE)<br />
v carriage switches for connected<br />
(CE) disconnected (CD) <strong>and</strong> test<br />
(CT) positions.<br />
b Programmable contacts:<br />
v 2 contacts (M2C)<br />
v 6 contacts (M6C).<br />
DB101111<br />
M2C contact.<br />
DB101156<br />
DB101149<br />
DB101110 DB101109<br />
DB101112<br />
OF contact.<br />
Remote operation page A-47<br />
b Remote ON/OFF:<br />
v gear motor<br />
v XF closing or MX opening voltage releases<br />
v PF ready-to-close contact<br />
options: RAR automatic or RES electrical remote reset<br />
- BPFE electrical closing pushbutton.<br />
b Remote tripping function:<br />
v MN voltage release<br />
- st<strong>and</strong>ard<br />
- adjustable or non-adjustable delay<br />
v or second MX voltage release.<br />
Gear motor.<br />
DB101113<br />
DB101147<br />
DB101114<br />
DB101150<br />
MX, XF <strong>and</strong> MN volage<br />
releases.<br />
Accessories page A-51<br />
b Auxiliary terminal shield.<br />
b Operation counter.<br />
b Escutcheon.<br />
b Transparent cover for escutcheon.<br />
b Escutcheon blanking plate.<br />
DB101115<br />
207E1050.indd<br />
version: 1.0