Measurements <strong>and</strong> programmable protection<br />
A: ammeter<br />
b I 1<br />
, I 2<br />
, I 3<br />
, I N<br />
, I earth-fault<br />
, I earth-leakage<br />
<strong>and</strong> maximeter for these measurements<br />
b fault indications<br />
b settings in amperes <strong>and</strong> in seconds.<br />
E: Energy P: A + power meter + programmable protection<br />
b incorporates all the rms<br />
measurements of<br />
Micrologic A, plus voltage,<br />
power factor, power <strong>and</strong><br />
energy metering<br />
measurements.<br />
v calculates the current<br />
dem<strong>and</strong> value<br />
v "Quickview" function for<br />
the automatic cyclical<br />
display of the most useful<br />
values (as st<strong>and</strong>ard or by<br />
selection).<br />
b measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, V peak<br />
, A peak<br />
, power factor <strong>and</strong><br />
maximeters <strong>and</strong> minimeters<br />
b IDMTL long-time protection, minimum <strong>and</strong> maximum voltage <strong>and</strong> frequency, voltage<br />
<strong>and</strong> current imbalance, phase sequence, reverse power<br />
b load shedding <strong>and</strong> reconnection depending on power or current<br />
b measurements of interrupted currents, differentiated fault indications,<br />
maintenance indications, H: P + harmonics<br />
event histories <strong>and</strong> b power quality: fundamentals, distortion, amplitude <strong>and</strong><br />
time-stamping, etc. phase of harmonics up to the 31st order<br />
b waveform capture after fault, alarm or on request<br />
b enhanced alarm programming: thresholds <strong>and</strong> actions.<br />
2.0 A<br />
DB127404<br />
Micrologic 2.0 A<br />
2.0 E<br />
DB127405<br />
Micrologic 2.0 E<br />
100 %<br />
100 %<br />
40 %<br />
40 %<br />
5.0 A<br />
DB127406<br />
Micrologic 5.0 A<br />
5.0 E<br />
DB127407<br />
Micrologic 5.0 E<br />
5.0 P<br />
DB101122<br />
5.0 H<br />
DB101122<br />
100 %<br />
100 %<br />
40 %<br />
40 %<br />
6.0 A<br />
DB101123<br />
6.0 E<br />
DB127408<br />
Micrologic 6.0 E<br />
6.0 P<br />
DB101124<br />
6.0 H<br />
DB101124<br />
100 %<br />
40 %<br />
7.0 A<br />
DB101123<br />
7.0 P<br />
DB101124<br />
7.0 H<br />
DB101124<br />